Modeling non-stationarity of kernel weights for k-space reconstruction in partially parallel imaging.

PURPOSE In partially parallel imaging, most k-space-based reconstruction algorithms such as GRAPPA adopt a single finite-size kernel to approximate the true relationship between sampled and nonsampled signals. However, the estimation of this kernel based on k-space signals is imperfect, and the authors are investigating methods dealing with local variation of k-space signals. METHODS To model nonstationarity of kernel weights, similar to performing a spatially adaptive regularization, the authors fit a set of linear functions using concepts from geographically weighted regression, a methodology used in geophysical analysis. Instead of a reconstruction with a single set of kernel weights, the authors use multiple sets. A missing signal is reconstructed with its kernel weights set determined by k-space clustering. Simulated and acquired MR data with several different image content and acquisition schemes, including MR tagging, were tested. A perceptual difference model (Case-PDM) was used to quantitatively evaluate the quality of over 1000 test images, and to optimize the parameters of our algorithm. RESULTS A MOdeling Non-stationarity of KErnel wEightS ("MONKEES") reconstruction with two sets of kernel weights gave reconstructions with significantly better image quality than the original GRAPPA in all test images. Using more sets produced improved image quality but with diminishing returns. As a rule of thumb, at least two sets of kernel weights, one from low- and the other from high frequency k-space, should be used. CONCLUSIONS The authors conclude that the MONKEES can significantly and robustly improve the image quality in parallel MR imaging, particularly, cardiac imaging.

[1]  R. Edelman,et al.  Signal‐to‐noise ratio and signal‐to‐noise efficiency in SMASH imaging , 1999, Magnetic resonance in medicine.

[2]  Wei Lin,et al.  A rapid and robust numerical algorithm for sensitivity encoding with sparsity constraints: Self‐feeding sparse SENSE , 2010, Magnetic resonance in medicine.

[3]  Donglai Huo,et al.  Robust GRAPPA reconstruction and its evaluation with the perceptual difference model , 2008, Journal of magnetic resonance imaging : JMRI.

[4]  K. Kwong,et al.  Parallel imaging reconstruction using automatic regularization , 2004, Magnetic resonance in medicine.

[5]  Donglai Huo,et al.  Application of perceptual difference model on regularization techniques of parallel MR imaging. , 2006, Magnetic resonance imaging.

[6]  Peiliang Xu Truncated SVD methods for discrete linear ill-posed problems , 1998 .

[7]  S. Fotheringham,et al.  Geographically Weighted Regression , 1998 .

[8]  Xiaoping P. Hu,et al.  Iterative GRAPPA (iGRAPPA) for improved parallel imaging reconstruction , 2008, Magnetic resonance in medicine.

[9]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[10]  Robin M Heidemann,et al.  SMASH, SENSE, PILS, GRAPPA: How to Choose the Optimal Method , 2004, Topics in magnetic resonance imaging : TMRI.

[11]  Daniel K Sodickson,et al.  3Parallel magnetic resonance imaging with adaptive radius in k‐space (PARS): Constrained image reconstruction using k‐space locality in radiofrequency coil encoded data , 2005, Magnetic resonance in medicine.

[12]  Donglai Huo,et al.  Quantitative image quality evaluation of MR images using perceptual difference models. , 2008, Medical physics.

[13]  Peter Kellman,et al.  Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA) , 2005, Magnetic resonance in medicine.

[14]  W. Block,et al.  Advances in locally constrained k‐space‐based parallel MRI , 2006, Magnetic resonance in medicine.

[15]  D. Sodickson,et al.  A generalized approach to parallel magnetic resonance imaging. , 2001, Medical physics.

[16]  John Tenhunen,et al.  Application of a geographically‐weighted regression analysis to estimate net primary production of Chinese forest ecosystems , 2005 .

[17]  Jonathan S. Lewin,et al.  Validation of a human vision model for image quality evaluation of fast interventional magnetic resonance imaging , 2002, J. Electronic Imaging.

[18]  Peng Qu,et al.  Discrepancy‐based adaptive regularization for GRAPPA reconstruction , 2006, Journal of magnetic resonance imaging : JMRI.

[19]  F. Huang,et al.  High‐pass GRAPPA: An image support reduction technique for improved partially parallel imaging , 2008, Magnetic resonance in medicine.

[20]  O. Simonetti,et al.  Artifact and noise suppression in GRAPPA imaging using improved k‐space coil calibration and variable density sampling , 2005, Magnetic resonance in medicine.