Smoothed l 0 Norm Regularization for Sparse-View X-Ray CT Reconstruction

Low-dose computed tomography (CT) reconstruction is a challenging problem in medical imaging. To complement the standard filtered back-projection (FBP) reconstruction, sparse regularization reconstruction gains more and more research attention, as it promises to reduce radiation dose, suppress artifacts, and improve noise properties. In this work, we present an iterative reconstruction approach using improved smoothed l 0 (SL0) norm regularization which is used to approximate l 0 norm by a family of continuous functions to fully exploit the sparseness of the image gradient. Due to the excellent sparse representation of the reconstruction signal, the desired tissue details are preserved in the resulting images. To evaluate the performance of the proposed SL0 regularization method, we reconstruct the simulated dataset acquired from the Shepp-Logan phantom and clinical head slice image. Additional experimental verification is also performed with two real datasets from scanned animal experiment. Compared to the referenced FBP reconstruction and the total variation (TV) regularization reconstruction, the results clearly reveal that the presented method has characteristic strengths. In particular, it improves reconstruction quality via reducing noise while preserving anatomical features.

[1]  Changqing Li,et al.  Nonconvex regularizations in fluorescence molecular tomography for sparsity enhancement , 2014, Physics in medicine and biology.

[2]  Ming Li,et al.  Low-dose CT reconstruction via L1 dictionary learning regularization using iteratively reweighted least-squares , 2016, BioMedical Engineering OnLine.

[3]  Axel Thran,et al.  Statistical Reconstruction of Material Decomposed Data in Spectral CT , 2013, IEEE Transactions on Medical Imaging.

[4]  F. Pfeiffer,et al.  X-ray computed tomography using curvelet sparse regularization. , 2015, Medical physics.

[5]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[6]  Shutao Li,et al.  Fast Acquisition and Reconstruction of Optical Coherence Tomography Images via Sparse Representation , 2013, IEEE Transactions on Medical Imaging.

[7]  Gaohang Yu,et al.  Sparse-view x-ray CT reconstruction via total generalized variation regularization , 2014, Physics in medicine and biology.

[8]  Jeffrey A. Fessler,et al.  Regularization Designs for Uniform Spatial Resolution and Noise Properties in Statistical Image Reconstruction for 3-D X-ray CT , 2015, IEEE Transactions on Medical Imaging.

[9]  J. Hsieh Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. , 1998, Medical physics.

[10]  D. Brenner,et al.  Computed tomography--an increasing source of radiation exposure. , 2007, The New England journal of medicine.

[11]  Jingyu Zhang,et al.  Projection domain denoising method based on dictionary learning for low-dose CT image reconstruction. , 2015, Journal of X-ray science and technology.

[12]  Jürgen Hesser,et al.  Accurate low-dose iterative CT reconstruction from few projections by Generalized Anisotropic Total Variation minimization for industrial CT. , 2015, Journal of X-ray science and technology.

[13]  Guang-Hong Chen,et al.  Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT. , 2015, Medical physics.

[14]  Jianhua Ma,et al.  Total Variation-Stokes Strategy for Sparse-View X-ray CT Image Reconstruction , 2014, IEEE Transactions on Medical Imaging.

[15]  Quan Zhang,et al.  Low-dose CT statistical iterative reconstruction via modified MRF regularization , 2016, Comput. Methods Programs Biomed..

[16]  A. Akan,et al.  Iterative image reconstruction using non-local means with total variation from insufficient projection data. , 2016, Journal of X-ray science and technology.

[17]  Kaushik Mahata,et al.  An Improved Smoothed $\ell^0$ Approximation Algorithm for Sparse Representation , 2010, IEEE Transactions on Signal Processing.

[18]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[19]  Jeffrey A. Fessler,et al.  Statistical image reconstruction for polyenergetic X-ray computed tomography , 2002, IEEE Transactions on Medical Imaging.

[20]  Ming Li,et al.  A prior-based metal artifact reduction algorithm for x-ray CT. , 2015, Journal of X-ray science and technology.

[21]  Li Ming,et al.  A Constrained Optimization Reconstruction Model for X-ray Computed Tomography Metal Artifact Suppression , 2015 .

[22]  A. Einstein,et al.  Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography. , 2007, JAMA.

[23]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[24]  L. Xing,et al.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization. , 2011, Medical physics.

[25]  Lei Xing,et al.  Sequentially reweighted TV minimization for CT metal artifact reduction. , 2013, Medical physics.

[26]  Huazhong Shu,et al.  Gamma regularization based reconstruction for low dose CT , 2015, Physics in medicine and biology.

[27]  Xiaochuan Pan,et al.  A constrained, total-variation minimization algorithm for low-intensity x-ray CT. , 2010, Medical physics.

[28]  Lei Zhang,et al.  Low-Dose X-ray CT Reconstruction via Dictionary Learning , 2012, IEEE Transactions on Medical Imaging.

[29]  Stephen P. Boyd,et al.  Convex Optimization , 2004, Algorithms and Theory of Computation Handbook.

[30]  Christian Jutten,et al.  A Fast Approach for Overcomplete Sparse Decomposition Based on Smoothed $\ell ^{0}$ Norm , 2008, IEEE Transactions on Signal Processing.

[31]  Tao Zhang,et al.  A Model of Regularization Parameter Determination in Low-Dose X-Ray CT Reconstruction Based on Dictionary Learning , 2015, Comput. Math. Methods Medicine.

[32]  Lei Xing,et al.  GPU computing in medical physics: a review. , 2011, Medical physics.