Flow and Leakage Characteristics of a Sashless Inclined Air-Curtain (sIAC) Fume Hood Containing Tall Pollutant-Generation Tanks

In many fume hood applications, pollutant-generation devices are tall. Human operators of a fume hood must stand close to the front of the hood and lift up their hands to reach the top opening of the tall tank. In this situation, it is inconvenient to access the conventional hood because the sash acts as a barrier. Also, the bluff-body wake in front of the operator's chest causes a problem. By using laser-assisted smoke flow visualization and tracer-gas test methods, the present study examines a sashless inclined air-curtain (sIAC) fume hood for tall pollutant-generation tanks, with a mannequin standing in front of the hood face. The configuration of the sIAC fume hood, which had the important element of a backward-inclined push-pull air curtain, was different from conventional configurations. Depending on suction velocity, the backward-inclined air curtain had three characteristic modes: straight, concave, and attachment. A large recirculation bubble covering the area—from the hood ceiling to the work surface—was formed behind the inclined air curtain in the straight and concave modes. In the attachment mode, the inclined air curtain was attached to the rear wall of the hood, about 50 cm from the hood ceiling, and bifurcated into up and down streams. Releasing the pollutants at an altitude above where the inclined air curtain was attached caused the suction slot to directly draw up the pollutants. Releasing pollutants in the rear recirculation bubble created a risk of pollutants’ leaking from the hood face. The tracer-gas (SF6) test results showed that operating the sIAC hood in the attachment mode, with the pollutants being released high above the critical altitude, could guarantee almost no leakage, even though a mannequin was standing in front of the sashless hood face.

[1]  Chih-Chieh Chen,et al.  Aerodynamics and performance verifications of test methods for laboratory fume cupboards. , 2007, The Annals of occupational hygiene.

[2]  Edward L. Gershey,et al.  Fume Hood Performance: Face Velocity Variability Inconsistent Air Volume Systems , 1998 .

[3]  Susan Woskie,et al.  A Review of Published Quantitative Experimental Studies on Factors Affecting Laboratory Fume Hood Performance , 2008, Journal of occupational and environmental hygiene.

[4]  R. Huang,et al.  Correlation Between Airflow Patterns and Performance of a Laboratory Fume Hood , 2006, Journal of occupational and environmental hygiene.

[5]  Melvin W First Laboratory chemical hoods: a historical perspective. , 2003, AIHA journal : a journal for the science of occupational and environmental health and safety.

[6]  M. Flynn,et al.  A review of wake effects on worker exposure , 1995 .

[7]  R. S. Tankin,et al.  A Study of Cold and Combusting Flow Around Bluff-Body Combustors , 1987 .

[8]  John H. Seinfeld,et al.  Fundamentals of Air Pollution Engineering , 1988 .

[9]  Rong Fung Huang,et al.  Improving flow and spillage characteristics of range hoods by using an inclined air-curtain technique. , 2011, The Annals of occupational hygiene.

[10]  Air sampling at the chest and ear as representative of the breathing zone. , 2001, AIHAJ : a journal for the science of occupational and environmental health and safety.

[11]  L E Ekberg,et al.  Required response time for variable air volume fume hood controllers. , 2000, The Annals of occupational hygiene.

[12]  C E Billings,et al.  Containment testing of laboratory hoods in the as-used condition. , 2000, Applied occupational and environmental hygiene.

[13]  J. Bennett,et al.  Control of wake-induced exposure using an interrupted oscillating jet. , 2003, AIHA journal : a journal for the science of occupational and environmental health and safety.

[14]  Louis J. DiBerardinis,et al.  A New Method for Quantitative, In-Use Testing of Laboratory Fume Hoods , 1989 .

[15]  Rong Fung Huang,et al.  Effects of walk-by and sash movement on contaminant leakage of air curtain-isolated fume hood. , 2007, Industrial health.

[16]  G. Thomas Saunders Laboratory Fume Hoods: A User's Manual , 1993 .

[17]  R F Huang,et al.  Aerodynamic characteristics and design guidelines of push-pull ventilation systems. , 2005, The Annals of occupational hygiene.

[18]  R F Huang,et al.  Development and evaluation of an air-curtain fume cabinet with considerations of its aerodynamics. , 2007, The Annals of occupational hygiene.

[19]  J. Lumley,et al.  A First Course in Turbulence , 1972 .

[20]  A. E. Johnson,et al.  CONTAINMENT TESTING OF FUME CUPBOARDS—I.METHODS , 1992 .

[21]  A. E. Johnson,et al.  CONTAINMENT TESTING OF FUME CUPBOARDS—II. TEST ROOM MEASUREMENTS , 1992 .