Quantitative assessments of burn degree by high-frequency ultrasonic backscattering and statistical model

An accurate and quantitative modality to assess the burn degree is crucial for determining further treatments to be properly applied to burn injury patients. Ultrasounds with frequencies higher than 20 MHz have been applied to dermatological diagnosis due to its high resolution and noninvasive capability. Yet, it is still lacking a substantial means to sensitively correlate the burn degree and ultrasonic measurements quantitatively. Thus, a 50 MHz ultrasound system was developed and implemented to measure ultrasonic signals backscattered from the burned skin tissues. Various burn degrees were achieved by placing a 100 °C brass plate onto the dorsal skins of anesthetized rats for various durations ranged from 5 to 20 s. The burn degrees were correlated with ultrasonic parameters, including integrated backscatter (IB) and Nakagami parameter (m) calculated from ultrasonic signals acquired from the burned tissues of a 5 × 1.4 mm (width × depth) area. Results demonstrated that both IB and m decreased exponentially with the increase of burn degree. Specifically, an IB of -79.0 ± 2.4 (mean ± standard deviation) dB for normal skin tissues tended to decrease to -94.0 ± 1.3 dB for those burned for 20 s, while the corresponding Nakagami parameters tended to decrease from 0.76 ± 0.08 to 0.45 ± 0.04. The variation of both IB and m was partially associated with the change of properties of collagen fibers from the burned tissues verified by samples of tissue histological sections. Particularly, the m parameter may be more sensitive to differentiate burned skin due to the fact that it has a greater rate of change with respect to different burn durations. These ultrasonic parameters in conjunction with high-frequency B-mode and Nakagami images could have the potential to assess the burn degree quantitatively.

[1]  C. Skouras,et al.  An audit of the use of laser Doppler imaging (LDI) in the assessment of burns of intermediate depth. , 2001, Burns : journal of the International Society for Burn Injuries.

[2]  Shyh-Hau Wang,et al.  The Effect of Kinetic Properties on Statistical Variations of Ultrasound Signals Backscattered from Flowing Blood , 2007, Ultrasound in medicine & biology.

[3]  K.K. Shung,et al.  Scattering of ultrasound from skeletal muscle tissue , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  P. Tsui,et al.  The effect of transducer characteristics on the estimation of Nakagami paramater as a function of scatterer concentration. , 2004, Ultrasound in medicine & biology.

[5]  Chien-Cheng Chang,et al.  Imaging local scatterer concentrations by the Nakagami statistical model. , 2007, Ultrasound in medicine & biology.

[6]  Qifa Zhou,et al.  Determining the acoustic properties of the lens using a high-frequency ultrasonic needle transducer. , 2007, Ultrasound in medicine & biology.

[7]  P. Shankar A general statistical model for ultrasonic backscattering from tissues , 2000 .

[8]  Characterization of bony tissues from ultrasonic backscattering using statistical models , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[9]  R. F. Wagner,et al.  Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[10]  R B Mazess,et al.  The effect of immediate and delayed cold immersion on burn edema formation and resorption. , 1979, The Journal of trauma.

[11]  Jeffrey W. Shupp,et al.  Critical Review of Burn Depth Assessment Techniques: Part I. Historical Review , 2009, Journal of burn care & research : official publication of the American Burn Association.

[12]  Chien-Cheng Chang,et al.  Classification of breast masses by ultrasonic Nakagami imaging: a feasibility study , 2008, Physics in medicine and biology.

[13]  L. Devgan,et al.  Modalities for the Assessment of Burn Wound Depth , 2006, Journal of burns and wounds.

[14]  Shyh-Hau Wang,et al.  The Effect of Kinetic Properties on Statistical Variations of Ultrasound Signals Backscattered from Flowing Blood , 2009 .

[15]  J. Greenleaf,et al.  Ultrasound Echo Envelope Analysis Using a Homodyned K Distribution Signal Model , 1994 .

[16]  M. Srinivasan,et al.  Statistics of envelope of high-frequency ultrasonic backscatter from human skin in vivo , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  S. L. Bridal,et al.  Reproducibility of skin characterization with backscattered spectra (12--25 MHz) in healthy subjects. , 2001, Ultrasound in medicine & biology.

[18]  C. Zachary,et al.  Ultrastructure of collagen thermally denatured by microsecond domain pulsed carbon dioxide laser. , 1998, Archives of dermatology.

[19]  Ronald E. Goans,et al.  Acoustic impedance variations at burn–nonburn interfaces in porcine skin , 1978 .

[20]  Ultrasonic Techniques to Assess the Properties of Hard and Soft Biological Tissues , 2004 .

[21]  M. Dyson,et al.  High‐frequency ultrasound imaging of the skin during normal and hypertensive pregnancies , 2001, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[22]  B. Goldberg,et al.  Classification of ultrasonic B-mode images of breast masses using Nakagami distribution , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  C. Burckhardt Speckle in ultrasound B-mode scans , 1978, IEEE Transactions on Sonics and Ultrasonics.

[24]  P M Shankar,et al.  A model for ultrasonic scattering from tissues based on the K distribution. , 1995, Physics in medicine and biology.

[25]  Phillip Blondeel,et al.  Assessment of burn depth and burn wound healing potential. , 2008, Burns : journal of the International Society for Burn Injuries.

[26]  Shyh-Hau Wang,et al.  Assessment of Blood Coagulation Under Various Flow Conditions With Ultrasound Backscattering , 2007, IEEE Transactions on Biomedical Engineering.

[27]  Shyh-Hau Wang,et al.  High frequency ultrasonic characterization of human vocal fold tissue. , 2007 .

[28]  J. Cantrell Can ultrasound assist an experienced surgeon in estimating burn depth? , 1984, Journal of Trauma.

[29]  K. Shung,et al.  An approach for measuring ultrasonic backscattering from biological tissues with focused transducers , 1997, IEEE Transactions on Biomedical Engineering.

[30]  B. Pomahac,et al.  Tissue engineering of skin. , 1998, Critical reviews in oral biology and medicine : an official publication of the American Association of Oral Biologists.

[31]  J.A. Johnson,et al.  A High-Frame Rate High-Frequency Ultrasonic System for Cardiac Imaging in Mice , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  R. Dykes,et al.  Sensory perception and neuroanatomical structures in normal and grafted skin of burn survivors. , 2005, Burns : journal of the International Society for Burn Injuries.

[33]  B. Goldberg,et al.  Classification of breast masses in ultrasonic B scans using Nakagami and K distributions , 2003, Physics in medicine and biology.

[34]  O. Jones,et al.  The reliability of digital images when used to assess burn wounds , 2003, Journal of telemedicine and telecare.

[35]  Chien-Cheng Chang,et al.  Feasibility study of using high-frequency ultrasonic Nakagami imaging for characterizing the cataract lens in vitro. , 2007, Physics in medicine and biology.

[36]  J. Cantrell,et al.  Ultrasonic pulse-echo determination of thermal injury in deep dermal burns. , 1977, Medical physics.

[37]  A H Roberts,et al.  Burn depth and its histological measurement. , 2001, Burns : journal of the International Society for Burn Injuries.

[38]  K. Shung,et al.  Variation in ultrasonic backscattering from skeletal muscle during passive stretching , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[39]  R. Lee,et al.  The relative thermal stability of tissue macromolecules and cellular structure in burn injury. , 2005, Burns : journal of the International Society for Burn Injuries.

[40]  M. Berson,et al.  In vivo high-frequency ultrasonic characterization of human dermis , 1999, IEEE Transactions on Biomedical Engineering.

[41]  Sheila MacNeil,et al.  The mechanism of skin graft contraction: an update on current research and potential future therapies. , 2008, Burns : journal of the International Society for Burn Injuries.

[42]  L. Cancio,et al.  Evolution of Burn Resuscitation in Operation Iraqi Freedom , 2006, Journal of burn care & research : official publication of the American Burn Association.

[43]  P. Shankar,et al.  Ultrasound speckle analysis based on the K distribution. , 1991, The Journal of the Acoustical Society of America.

[44]  Salvador Gonzalez,et al.  Quantitative ultrasonic methods for characterization of skin lesions in vivo. , 2003, Ultrasound in medicine & biology.

[45]  C W Hanke,et al.  Quantitative assessment of burn injury in porcine skin with high-frequency ultrasonic imaging. , 1986, Investigative radiology.

[46]  F. Foster,et al.  High-frequency intracoronary ultrasound imaging. , 1997, Seminars in interventional cardiology : SIIC.

[47]  K.K. Shung,et al.  In vivo measurements of ultrasonic backscattering in blood , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[48]  Y P Huang,et al.  High frequency ultrasound assessment of skin fibrosis: clinical results. , 2007, Ultrasound in medicine & biology.

[49]  R. Richard,et al.  Managing superficial burn wounds. , 2002, Advances in skin & wound care.

[50]  K. Shung,et al.  Diagnostic Ultrasound: Imaging and Blood Flow Measurements , 2005 .

[51]  Antoni Nowakowski,et al.  Burn depths evaluation based on active dynamic IR thermal imaging--a preliminary study. , 2006, Burns : journal of the International Society for Burn Injuries.