Noninvasive structural and microvascular anatomy of oral mucosae using handheld optical coherence tomography.

In this study, we demonstrated the feasibility of using a handheld optical coherence tomography (OCT) for in vivo visualizations of the microstructural and microvascular features of various oral mucosal types. To scan arbitrary locations of the oral mucosa, a scanning probe was developed, composed of a probe body fabricated by a 3D printer, miniaturized two-axis galvanometer, relay lenses, and reflective prism. With a 3D printing technique, the probe weight and the system volume were greatly reduced, enabling the effective improvement of imaging artifacts from unconscious motion and system complexity. Additionally, in our design, the distal end of the probe can be switched to fit various oral conditions, and the optical parameters of the probe, such as the transverse resolution, working distance, and probe length can be easily varied. The results showed that the epithelium and lamina propria layers, as well as the fungiform papilla and salivary gland, were differentiated. Moreover, various microcirculation features at different mucosal sites were identified that are potentially effective indicators for the diagnosis of premalignant lesions. The demonstrated results indicate that the developed OCT system is a promising tool for noninvasive imaging of oral mucosae.

[1]  Ann M Gillenwater,et al.  Confocal microscopy for real-time detection of oral cavity neoplasia. , 2003, Clinical cancer research : an official journal of the American Association for Cancer Research.

[2]  Jun Zhang,et al.  Advances in oral cancer detection using optical coherence tomography , 2005, IEEE Journal of Selected Topics in Quantum Electronics.

[3]  Zhongping Chen,et al.  Noninvasive imaging of oral premalignancy and malignancy. , 2005, Journal of biomedical optics.

[4]  Sina Farsiu,et al.  Coherence revival multiplexed, buffered swept source optical coherence tomography: 400 kHz imaging with a 100 kHz source. , 2014, Optics letters.

[5]  Liang Liu,et al.  Handheld optical coherence tomography angiography. , 2017, Biomedical optics express.

[6]  Meng-Tsan Tsai,et al.  Feasibility of ablative fractional laser-assisted drug delivery with optical coherence tomography. , 2014, Biomedical optics express.

[7]  Martin F. Kraus,et al.  Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror. , 2013, Biomedical optics express.

[8]  Zhongping Chen,et al.  Real-time phase-resolved optical coherence tomography and optical Doppler tomography. , 2002, Optics Express.

[9]  Ruikang K. Wang,et al.  Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography. , 2010, Optics letters.

[10]  Yu-Hsuan Liu,et al.  Acoustic-actuated optical coherence angiography. , 2016, Optics letters.

[11]  Ruikang K. Wang,et al.  In vivo imaging of functional microvasculature within tissue beds of oral and nasal cavities by swept-source optical coherence tomography with a forward/side-viewing probe , 2014, Biomedical optics express.

[12]  S Silverman,et al.  Early diagnosis of oral cancer , 1988, Cancer.

[13]  Pierre Lane,et al.  Wide-field in vivo oral OCT imaging. , 2015, Biomedical optics express.

[14]  J. Gluckman,et al.  Tumor angiogenesis as a prognostic indicator in T2‐T4 oral cavity squamous cell carcinoma: A clinical‐pathologic correlation , 1997, Head & neck.

[15]  Martin J Leahy,et al.  Cellular phone‐based photoplethysmographic imaging , 2011, Journal of biophotonics.

[16]  P. Messina,et al.  Oral microcirculation in post-menopause: a possible correlation with periodontitis. , 2012, Gerodontology.

[17]  Rodrigo Cuenca,et al.  Reflectance confocal endomicroscope with optical axial scanning for in vivo imaging of the oral mucosa. , 2014, Biomedical optics express.

[18]  Mohammad Sultan Mahmud,et al.  Review of speckle and phase variance optical coherence tomography to visualize microvascular networks , 2013, Journal of biomedical optics.

[19]  Hsiang-Chieh Lee,et al.  Effective indicators for diagnosis of oral cancer using optical coherence tomography. , 2008, Optics express.

[20]  Adrian Mariampillai,et al.  Speckle variance detection of microvasculature using swept-source optical coherence tomography. , 2008, Optics letters.

[21]  Chi-Kuang Sun,et al.  Characterization of oral squamous cell carcinoma based on higher‐harmonic generation microscopy , 2012, Journal of biophotonics.

[22]  Zhongping Chen,et al.  In vivo optical coherence tomography for the diagnosis of oral malignancy , 2004, Lasers in surgery and medicine.

[23]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[24]  Adrian Bradu,et al.  Dual instrument for in vivo and ex vivo OCT imaging in an ENT department , 2012, Biomedical optics express.

[25]  Chih-Jen Yu,et al.  High speed interferometric ellipsometer. , 2008, Optics express.

[26]  M. Leahy,et al.  Correlation mapping method for generating microcirculation morphology from optical coherence tomography (OCT) intensity images , 2010, Journal of biophotonics.

[27]  Jeroen J. Bax,et al.  Non-invasive assessment of microcirculation by sidestream dark field imaging as a marker of coronary artery disease in diabetes , 2013, Diabetes & vascular disease research.

[28]  M. Chan,et al.  Simultaneous 0.8, 1.0, and 1.3 μm multispectral and common-path broadband source for optical coherence tomography. , 2014, Optics letters.

[29]  Ruikang K. Wang,et al.  Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds. , 2010, Optics express.

[30]  Martin Leahy,et al.  In vivo imaging of the microcirculation of the volar forearm using correlation mapping optical coherence tomography (cmOCT) , 2011, Biomedical optics express.

[31]  Jeehyun Kim,et al.  Handheld Optical Coherence Tomography Scanner for Primary Care Diagnostics , 2011, IEEE Transactions on Biomedical Engineering.

[32]  Bernard Choi,et al.  Intensity-based modified Doppler variance algorithm: application to phase instable and phase stable optical coherence tomography systems , 2011, Optics express.

[33]  E. Sturgis,et al.  Squamous cell carcinoma of the head and neck in nonsmokers: clinical and biologic characteristics and implications for management , 2001, Current opinion in oncology.

[34]  R. Gandour-Edwards,et al.  Multimodal in vivo imaging of oral cancer using fluorescence lifetime, photoacoustic and ultrasound techniques. , 2013, Biomedical optics express.

[35]  B. Wong,et al.  In vivo optical coherence tomography of the human oral cavity and oropharynx. , 2006, Archives of otolaryngology--head & neck surgery.

[36]  W. Arnold,et al.  The oral mucosal surface and blood vessels , 2013, Head & Face Medicine.

[37]  Pierre Lane,et al.  A high-efficiency fiber-based imaging system for co-registered autofluorescence and optical coherence tomography. , 2014, Biomedical optics express.

[38]  A. Jemal,et al.  Cancer statistics, 2015 , 2015, CA: a cancer journal for clinicians.

[39]  J. Gluckman,et al.  Tumor angiogenesis in T1 oral cavity squamous cell carcinoma: Role in predicting tumor aggressiveness , 1996, Head & neck.

[40]  G. Gynther,et al.  Direct oral microscopy and its value in diagnosing mucosal lesions: a pilot study. , 2000, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[41]  C A Squier,et al.  Biology of oral mucosa and esophagus. , 2001, Journal of the National Cancer Institute. Monographs.

[42]  Hsiang-Chieh Lee,et al.  Delineation of an oral cancer lesion with swept-source optical coherence tomography. , 2008, Journal of biomedical optics.

[43]  S. Weed,et al.  Multi-photon Imaging of Tumor Cell Invasion in an Orthotopic Mouse Model of Oral Squamous Cell Carcinoma , 2011, Journal of visualized experiments : JoVE.

[44]  Bahar Davoudi,et al.  Noninvasive in vivo structural and vascular imaging of human oral tissues with spectral domain optical coherence tomography , 2012, Biomedical optics express.

[45]  Ruikang K. Wang,et al.  High speed spectral domain optical coherence tomography for retinal imaging at 500,000 A‑lines per second , 2011, Biomedical optics express.

[46]  J. Fujimoto,et al.  High-precision, high-accuracy ultralong-range swept-source optical coherence tomography using vertical cavity surface emitting laser light source. , 2013, Optics letters.