An anthropomorphic multimodality (CT/MRI) head phantom prototype for end-to-end tests in ion radiotherapy.

With the increasing complexity of external beam therapy "end-to-end" tests are intended to cover every step from therapy planning through to follow-up in order to fulfill the higher demands on quality assurance. As magnetic resonance imaging (MRI) has become an important part of the treatment process, established phantoms such as the Alderson head cannot fully be used for those tests and novel phantoms have to be developed. Here, we present a feasibility study of a customizable multimodality head phantom. It is initially intended for ion radiotherapy but may also be used in photon therapy. As basis for the anthropomorphic head shape we have used a set of patient computed tomography (CT) images. The phantom recipient consisting of epoxy resin was produced by using a 3D printer. It includes a nasal air cavity, a cranial bone surrogate (based on dipotassium phosphate), a brain surrogate (based on agarose gel), and a surrogate for cerebrospinal fluid (based on distilled water). Furthermore, a volume filled with normoxic dosimetric gel mimicked a tumor. The entire workflow of a proton therapy could be successfully applied to the phantom. CT measurements revealed CT numbers agreeing with reference values for all surrogates in the range from 2 HU to 978 HU (120 kV). MRI showed the desired contrasts between the different phantom materials especially in T2-weighted images (except for the bone surrogate). T2-weighted readout of the polymerization gel dosimeter allowed approximate range verification.

[1]  M. Oldham,et al.  Polymer gel dosimetry. , 2010, Physics in medicine and biology.

[2]  L. Lüdemann,et al.  Use of BANG polymer gel for dose measurements in a 68 MeV proton beam. , 2003, Medical physics.

[3]  Frederik L. Giesel,et al.  3D printing based on imaging data: review of medical applications , 2010, International Journal of Computer Assisted Radiology and Surgery.

[4]  M. Saito Optimized low-kV spectrum of dual-energy CT equipped with high-kV tin filtration for electron density measurements. , 2011, Medical physics.

[5]  Marco Nolden,et al.  The Medical Imaging Interaction Toolkit , 2005, Medical Image Anal..

[6]  S. Savolainen,et al.  Study of the relative dose-response of BANG-3 polymer gel dosimeters in epithermal neutron irradiation. , 2003, Physics in medicine and biology.

[7]  Steffen Greilich,et al.  Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates , 2014, Physics in medicine and biology.

[8]  M. Saito Potential of dual-energy subtraction for converting CT numbers to electron density based on a single linear relationship. , 2012, Medical physics.

[9]  W. Kalender,et al.  Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions , 2000 .

[10]  J. Seco,et al.  Deriving effective atomic numbers from DECT based on a parameterization of the ratio of high and low linear attenuation coefficients , 2013, Physics in medicine and biology.

[11]  A. Berg,et al.  High resolution dosimetry in monoenergetic proton beam therapy on a normoxic polymer gel: the importance of high spatial resolution for reduced Bragg-Peak-quenching , 2013 .

[12]  E. Pedroni,et al.  The calibration of CT Hounsfield units for radiotherapy treatment planning. , 1996, Physics in medicine and biology.