Seismic design, modelling and assessment of self-centering steel frames using post-tensioned connections with web hourglass shape pins

A new self-centering steel post-tensioned connection using web hourglass shape pins (WHPs) has been recently developed and experimentally validated. The connection isolates inelastic deformations in WHPs, avoids damage in other connection parts as well as in beams and columns, and eliminates residual drifts. WHPs do not interfere with the composite slab and can be very easily replaced without bolting or welding, and so, the connection enables non-disruptive repair and rapid return to building occupancy in the aftermath of a strong earthquake. This paper presents a simplified nonlinear model for the connection and the associated beams and columns that consists of nonlinear beam-column elements, and hysteretic and contact zero-length spring elements appropriately placed in the beam-column interface. The model was calibrated against experimental results and found to accurately simulate the connection behaviour. A prototype building was selected and designed as a conventional steel moment-resisting frame (MRF) according to Eurocode 8 or as a self-centering steel MRF (SC-MRF) using the connection with WHPs. Seismic analyses results show that the conventional MRF and the SC-MRF have comparable peak storey drifts, and highlight the inherent potential of the SC-MRF to eliminate damage in beams and residual drifts. The paper also shows that repair of damage in the conventional MRF will be costly and disruptive after the design basis earthquake, and, not financially viable after the maximum considered earthquake due to large residual drifts.

[1]  Keh-Chyuan Tsai,et al.  Evaluating performance of post‐tensioned steel connections with strands and reduced flange plates , 2006 .

[2]  James M. Ricles,et al.  Experimental evaluation of the seismic performance of steel MRFs with compressed elastomer dampers using large-scale real-time hybrid simulation , 2011 .

[3]  Keh-Chyuan Tsai,et al.  Seismic self‐centering steel beam‐to‐column moment connections using bolted friction devices , 2008 .

[4]  J. McCormick,et al.  PERMISSIBLE RESIDUAL DEFORMATION LEVELS FOR BUILDING STRUCTURES CONSIDERING BOTH SAFETY AND HUMAN ELEMENTS , 2008 .

[5]  Chung-Che Chou,et al.  Post-tensioned self-centering moment connections with beam bottom flange energy dissipators , 2009 .

[6]  George Vasdravellis,et al.  Steel Post-Tensioned Connections with Web Hourglass Pins: Towards Earthquake Resilient Steel Structures , 2015 .

[7]  Richard Sause,et al.  Posttensioned Seismic-Resistant Connections for Steel Frames , 2001 .

[8]  Theodore L. Karavasilis,et al.  Hysteretic model for steel energy dissipation devices and evaluation of a minimal-damage seismic design approach for steel buildings , 2012 .

[9]  Johnny Sun,et al.  Development of Ground Motion Time Histories for Phase 2 of the FEMA/SAC Steel Project , 1997 .

[10]  Keh-Chyuan Tsai,et al.  Self‐centering steel connections with steel bars and a discontinuous composite slab , 2009 .

[11]  Richard Sause,et al.  Behavior and Design of Posttensioned Steel Frame Systems , 2007 .

[12]  Andre Filiatrault,et al.  Posttensioned Energy Dissipating Connections for Moment-Resisting Steel Frames , 2002 .

[13]  Brian Uy,et al.  Large-Scale Experimental Validation of Steel Posttensioned Connections with Web Hourglass Pins , 2013 .

[14]  Luís Simões da Silva,et al.  Design of Steel Structures: Eurocode 3: Design of Steel Structures, Part 1-1: General Rules and Rules for Buildings , 2010 .

[15]  Richard Sause,et al.  Experimental Study of a Self-Centering Beam–Column Connection with Bottom Flange Friction Device , 2009 .

[16]  Richard Sause,et al.  Experimental Evaluation of Earthquake Resistant Posttensioned Steel Connections , 2002 .

[17]  Hyung-Joon Kim,et al.  Seismic design procedure and seismic response of post‐tensioned self‐centering steel frames , 2009 .

[18]  Hyung J. Kim,et al.  Friction Damped Posttensioned Self-Centering Steel Moment-Resisting Frames , 2008 .

[19]  Martin S. Williams,et al.  A Comparison of Viscous Damper Placement Methods for Improving Seismic Building Design , 2012 .

[20]  Richard Sause,et al.  Seismic Performance of Post-tensioned Steel Moment Resisting Frames With Friction Devices , 2005 .

[21]  Richard Sause,et al.  Experimental studies of full-scale posttensioned steel connections , 2005 .

[22]  Theodore L. Karavasilis,et al.  Seismic structural and non-structural performance evaluation of highly damped self-centering and conventional systems , 2011 .