A Wearable Combined Wrist Pulse Measurement System Using Airbags for Pressurization

The pulse measurement instrument is based on traditional Chinese medicine (TCM) and is used to collect the pulse of patients to assist in diagnosis and treatment. In the existing pulse measurement system, desktop devices have large volumes, complex pressure adjusting operations, and unstable pressurization. Wearable devices tend to have no pressurization function or the function to pressurize three channels separately, which are not consistent with the diagnostic method in TCM. This study constructs a wearable pulse measurement system using airbags for pressurization. This system uses guide plates, guide grooves, and positioning screws to adjust the relative position of the wristband and locate Cun, Guan and Chi regions. The pulse signal measured by the sensor is collected and sent to a computer by microcontroller unit. In experiments, this system successfully obtains the best pulse-taking pressure, its pulse waveform under continuous decompression, and the pulse waveform of three regions under light, medium, and heavy pressure. Compared with the existing technology, the system has the advantages of supporting single-region and three-region pulse acquisition, independent pressure adjustment, and position adjustment. It meets the needs of home, medical, and experimental research, and it is convenient and comfortable to wear and easy to carry.

[1]  Wang Yiqin,et al.  Research on a Novel Three-Channel Self-pressurized Wrist Pulse Acquisition System , 2015, BIOSTEC 2015.

[2]  Emma King,et al.  The Reliable Measurement of Radial Pulse Characteristics , 2002, Acupuncture in medicine : journal of the British Medical Acupuncture Society.

[3]  Jeon Lee,et al.  A Study on Correlation between BMI and Oriental Medical Pulse Diagnosis Using Ultrasonic Wave , 2009 .

[4]  Yiqin Wang Progress and prospect of objectivity study on four diagnostic methods in Traditional Chinese Medicine , 2010, 2010 IEEE International Conference on Bioinformatics and Biomedicine Workshops (BIBMW).

[5]  David Zhang,et al.  An Optimal Pulse System Design by Multichannel Sensors Fusion , 2016, IEEE Journal of Biomedical and Health Informatics.

[6]  M.D. Fox,et al.  No touch pulse measurement by optical interferometry , 1994, IEEE Transactions on Biomedical Engineering.

[7]  David Zhang,et al.  Design and implementation of a multi-channel pulse signal acquisition system , 2012, 2012 5th International Conference on BioMedical Engineering and Informatics.

[8]  Rui Guo,et al.  Analysis of TCM Pulse Instrument Development Progress , 2016 .

[9]  Ching-Hsing Luo,et al.  Using an array sensor to determine differences in pulse diagnosis—Three positions and nine indicators , 2014 .

[10]  Ki H. Chon,et al.  Multi-channel pulse oximetry for wearable physiological monitoring , 2013, 2013 IEEE International Conference on Body Sensor Networks.

[11]  Robert C. Roberts,et al.  MEMS pressure sensor array wearable for Traditional Chinese Medicine pulse-taking , 2017, 2017 IEEE 14th International Conference on Wearable and Implantable Body Sensor Networks (BSN).

[12]  T. Hsu,et al.  The ventricular-arterial coupling system can be analyzed by the eigenwave modes of the whole arterial system , 2008 .

[13]  Rong-Seng Chang,et al.  A Non-Contact Pulse Automatic Positioning Measurement System for Traditional Chinese Medicine , 2015, Sensors.

[14]  Baoyan Liu,et al.  The basic theory, diagnostic, and therapeutic system of traditional Chinese medicine and the challenges they bring to statistics , 2012, Statistics in medicine.

[15]  V. K. Jayaraman,et al.  Nadi Tarangini: A Pulse Based Diagnostic System , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Yu-Feng Chung,et al.  Possibility of quantifying TCM finger-reading sensations: II. An example of health standardization , 2012 .

[17]  Young Ju Jeon,et al.  Novel Diagnostic Algorithm for the Floating and Sunken Pulse Qualities and Its Clinical Test , 2011, Evidence-based complementary and alternative medicine : eCAM.

[18]  Minvydas Ragulskis,et al.  Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis , 2013, Sensors.

[19]  Ling Y. Wei,et al.  Spectrum Analysis of Human Pulse , 1983, IEEE Transactions on Biomedical Engineering.

[20]  Joe-Air Jiang,et al.  A Novel Pulse Measurement System by Using Laser Triangulation and a CMOS Image Sensor , 2007, Sensors.

[21]  Ki H. Chon,et al.  Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph , 2016, Sensors.

[22]  U. Rajendra Acharya,et al.  Automated diagnosis of Coronary Artery Disease affected patients using LDA, PCA, ICA and Discrete Wavelet Transform , 2013, Knowl. Based Syst..