Miniaturization of a biomedical gas sensor.

In a previous study, we concluded that a conductivity based PCO2 sensor is an attractive solution for early detection of ischemia and presented two design geometries. For organ surface measurements, the planar design was suitable but it was difficult to insert the sensor into the tissue. A cylindrical design solution was favored for insertion due to the large membrane contact area and easy placement in a medical catheter. Since the previous cylindrical prototype was large and could damage the tissue, a more miniaturized sensor was needed. In the current paper, we present a miniaturized sensor with an outer diameter of 1 mm. The applied technology for manufacturing the sensor was a combination of mechanical turning, excimer laser drilling and conventional molding technique. The materials applied were PEEK (polyetherether ketone), PI (polyimide) with gold layers and polysiloxane. The membrane had to be gas permeable while acting as a barrier for ion transport, and was made of polysiloxane and had a thickness of 100-150 microm. The miniaturized sensor was tested for calibration, response time, drifting and pressure sensitivity. The results show that the miniaturized PCO2 sensor is capable of rapid and stable measurements both in vitro and ex vivo. The result from this study will be applied for the industrial manufacturing of such a biomedical sensor as a clinical product.

[1]  M. Brand,et al.  Conductimetric gas sensor for carbon dioxide , 1978 .

[2]  K. Foster,et al.  Dielectric properties of tissues and biological materials: a critical review. , 1989, Critical reviews in biomedical engineering.

[3]  Clifford D. Ferris,et al.  Four‐Electrode Null Techniques for Impedance Measurement with High Resolution , 1968 .

[4]  N. D. Rooij,et al.  Integrated Blood-Gas Sensor for pO2, pCO2 and pH , 1993 .

[5]  J. Severinghaus,et al.  Electrodes for blood pO2 and pCO2 determination. , 1958, Journal of applied physiology.

[6]  T. Tønnessen,et al.  PCO2 electrodes at the surface of the kidney detect ischaemia , 1996, Acta anaesthesiologica Scandinavica.

[7]  Sverre Grimnes,et al.  Bioimpedance and Bioelectricity Basics , 2000 .

[8]  T. Tønnessen Biological basis for PCO2 as a detector of ischemia. , 1997, Acta anaesthesiologica Scandinavica.

[9]  Stow Rw,et al.  Rapid measurement of the tension of carbon dioxide in blood. , 1957 .

[10]  R. Stow,et al.  Rapid measurement of the tension of carbon dioxide in blood. , 1957, Archives of physical medicine and rehabilitation.

[11]  W. M. Haynes CRC Handbook of Chemistry and Physics , 1990 .

[12]  R. C. Weast CRC Handbook of Chemistry and Physics , 1973 .

[13]  D. Lübbers,et al.  APCO2 surface electrode working on the principle of electrical conductivity , 1979, Pflügers Archiv.

[14]  T. I. Tøosnnessen Biological basis for PCO2 as a detector of ischemia , 1997 .

[15]  B. Onaral,et al.  Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies , 1982, Medical and Biological Engineering and Computing.

[16]  H P Schwan,et al.  ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS * , 1968, Annals of the New York Academy of Sciences.

[17]  R. Schlichtig,et al.  Distinguishing between aerobic and anaerobic appearance of dissolved CO2 in intestine during low flow. , 1994, Journal of applied physiology.

[18]  T. Tønnessen,et al.  Detection of organ ischemia during hemorrhagic shock , 2003, Acta anaesthesiologica Scandinavica.

[19]  Peyman Mirtaheri,et al.  A new biomedical sensor for measuring PCO2. , 2004, Physiological measurement.

[20]  Peyman Mirtaheri,et al.  Detection of ischemia by Pco2 before adenosine triphosphate declines in skeletal muscle , 2004, Critical care medicine.