A (short) history of image-guided radiotherapy.

Progress in radiotherapy is guided by the need to realize improved dose distributions, i.e. the ability to reduce the treatment volume toward the target volume and still ensuring coverage of that target volume in all dimensions. Poor ability to control the tumour's location limits the accuracy with which radiation can be delivered to tumour-bearing tissue. Image-guided radiation therapy (IGRT) aims at in-room imaging guiding the radiation delivery based on instant knowledge of the target location and changes in tumour volume during treatment. Advancements are usually not to be attributed to a single event, but rather a combination of many small improvements that together enable a superior result. Image-guidance is an important link in the treatment chain and as such a major factor in this synergetic process. A historic review shows that many of the so-called new developments are not so new at all, but did not make it into mainstream radiotherapy practice at that time. Recent developments in improved IT infrastructures, novel irradiation techniques, and better knowledge of functional and morphologic information may have created the need and optimal environment to revive the interest in IGRT.

[1]  C. Perez,et al.  Principles and Practice of Radiation Oncology , 1987 .

[2]  C. Ma,et al.  Dosimetry and preliminary acute toxicity in the first 100 men treated for prostate cancer on a randomized hypofractionation dose escalation trial. , 2006, International journal of radiation oncology, biology, physics.

[3]  P J Biggs,et al.  A diagnostic X ray field verification device for a 10 MV linear accelerator. , 1984, International journal of radiation oncology, biology, physics.

[4]  R. K. Münch,et al.  A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. , 2000, Physics in medicine and biology.

[5]  D Verellen,et al.  Optimal control of set-up margins and internal margins for intra- and extracranial radiotherapy using stereoscopic kilovoltage imaging. , 2006, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.

[6]  M van Herk,et al.  A matrix ionisation chamber imaging device for on-line patient setup verification during radiotherapy. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  P. Munro,et al.  Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58. , 2001, Medical physics.

[8]  G E Hanks,et al.  Patterns of care study: Hodgkin's disease relapse rates and adequacy of portals , 1983, Cancer.

[9]  Daniela Thorwarth,et al.  Hypoxia dose painting by numbers: a planning study. , 2007, International journal of radiation oncology, biology, physics.

[10]  A Boxwala,et al.  Core-based portal image registration for automatic radiotherapy treatment verification. , 1995, International journal of radiation oncology, biology, physics.

[11]  F. V. Heuvel,et al.  Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging , 1995 .

[12]  R S Fields,et al.  Technique for verifying treatment fields using portal images with diagnostic quality. , 1987, International journal of radiation oncology, biology, physics.

[13]  D Verellen,et al.  Target localization and treatment verification for intensity modulated conformal radiation therapy of the head and neck region. The AZ-VUB experience. Akademisch Ziekenhuis-Vrije Universiteit Brussel. , 1998, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al].

[14]  M van Herk,et al.  Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images. , 1991, Physics in medicine and biology.

[15]  M. Goitein,et al.  Accuracy of radiation field alignment in clinical practice. , 1985, International journal of radiation oncology, biology, physics.

[16]  M van Herk,et al.  Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data. , 1996, Medical physics.

[17]  D Followill,et al.  Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy. , 1997, International journal of radiation oncology, biology, physics.

[18]  J. Diamond,et al.  Patterns of change in the physics and technical support of radiation therapy in the USA 1975-1986. , 1989, International journal of radiation oncology, biology, physics.

[19]  J. Deasy Partial tumor boosts: even more attractive than theory predicts? , 2001, International journal of radiation oncology, biology, physics.

[20]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[21]  A Fenster,et al.  Daily monitoring and correction of radiation field placement using a video-based portal imaging system: a pilot study. , 1992, International journal of radiation oncology, biology, physics.

[22]  P. Munro,et al.  X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays. , 1998, Medical physics.

[23]  A G Haus,et al.  The effect of immobilisation on localisation error in the radiotherapy of head and neck cancer. , 1976, Clinical radiology.

[24]  J. Sham,et al.  Xerostomia and quality of life after intensity-modulated radiotherapy vs. conventional radiotherapy for early-stage nasopharyngeal carcinoma: initial report on a randomized controlled clinical trial. , 2006, International journal of radiation oncology, biology, physics.

[25]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[26]  J. Pouliot,et al.  Evaluation of ultrasound-based prostate localization for image-guided radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[27]  P M Evans,et al.  The application of transit dosimetry to precision radiotherapy. , 1996, Medical physics.

[28]  F. Lohr,et al.  Stereotactic single-dose radiation therapy of liver tumors: results of a phase I/II trial. , 2001, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[29]  Quynh-Thu Le,et al.  The effectiveness of breath-holding to stabilize lung and pancreas tumors during radiosurgery. , 2002, International journal of radiation oncology, biology, physics.

[30]  Steven D Chang,et al.  Image-guided robotic radiosurgery for spinal metastases. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  Joos V Lebesque,et al.  Dose-response in radiotherapy for localized prostate cancer: results of the Dutch multicenter randomized phase III trial comparing 68 Gy of radiotherapy with 78 Gy. , 2006, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[32]  K. Forster,et al.  Image-guided radiosurgery for the spine and pancreas. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[33]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[34]  M O Leach,et al.  Applications of magnetic resonance spectroscopy in radiotherapy treatment planning. , 2006, The British journal of radiology.

[35]  E. Hall,et al.  Radiation oncology: a century of achievements , 2004, Nature Reviews Cancer.

[36]  Joos V Lebesque,et al.  Inclusion of geometric uncertainties in treatment plan evaluation. , 2002, International journal of radiation oncology, biology, physics.

[37]  M Coghe,et al.  Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couch. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[38]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[39]  A G Visser,et al.  Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams. , 1998, Medical physics.

[40]  Mark P. Carol,et al.  Peacock™: A system for planning and rotational delivery of intensity‐modulated fields , 1995, Int. J. Imaging Syst. Technol..

[41]  G T Chen,et al.  Correlation of projection radiographs in radiation therapy using open curve segments and points. , 1992, Medical physics.

[42]  K Parodi,et al.  Dose quantification from in-beam positron emission tomography. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[43]  Dirk Verellen,et al.  Setup accuracy of stereoscopic X-ray positioning with automated correction for rotational errors in patients treated with conformal arc radiotherapy for prostate cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[44]  A. Brahme,et al.  Biologically Optimized 3-Dimensional In Vivo Predictive Assay-based Radiation Therapy Using Positron Emission Tomography-Computerized Tomography Imaging , 2003, Acta oncologica.

[45]  Søren M Bentzen,et al.  Theragnostic imaging for radiation oncology: dose-painting by numbers. , 2005, The Lancet. Oncology.

[46]  D Verellen,et al.  A computerized remote table control for fast on-line patient repositioning: implementation and clinical feasibility. , 2000, Medical physics.

[47]  L. Muren,et al.  CT-guided intensity-modulated radiotherapy for bladder cancer: isocentre shifts, margins and their impact on target dose. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[48]  C. Jonsson,et al.  Development of dose delivery verification by PET imaging of photonuclear reactions following high energy photon therapy , 2006, Physics in medicine and biology.

[49]  D. Verellen,et al.  Innovations in image-guided radiotherapy , 2007, Nature Reviews Cancer.

[50]  A. Brahme,et al.  An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion. , 1998, Physics in medicine and biology.

[51]  R. Jeraj,et al.  Re-optimization in adaptive radiotherapy. , 2002, Physics in medicine and biology.

[52]  L. Xing,et al.  Overview of image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[53]  Radhe Mohan,et al.  Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system. , 2003, Medical physics.

[54]  E. Hall,et al.  Intensity-modulated radiation therapy, protons, and the risk of second cancers. , 2006, International journal of radiation oncology, biology, physics.

[55]  Jean Pouliot,et al.  Positional stability of electromagnetic transponders used for prostate localization and continuous, real-time tracking. , 2007, International journal of radiation oncology, biology, physics.

[56]  C. J. Karzmark,et al.  The Stanford medical linear accelerator. II. Installation and physical measurements. , 1959, Radiology.

[57]  D. Low,et al.  A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT. , 2006, Medical physics.

[58]  E. Hall,et al.  Radiation-induced second cancers: the impact of 3D-CRT and IMRT. , 2003, International journal of radiation oncology, biology, physics.

[59]  A. Haus,et al.  A technique for imaging patient treatment area during a therapeutic radiation exposure. , 1970, Radiology.

[60]  Masahiro Hiraoka,et al.  Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frame. , 2005, International journal of radiation oncology, biology, physics.

[61]  Steve B. Jiang,et al.  The management of imaging dose during image-guided radiotherapy: report of the AAPM Task Group 75. , 2007, Medical physics.

[62]  C Clifton Ling,et al.  From IMRT to IGRT: frontierland or neverland? , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[63]  H. E. Johns,et al.  A precision cobalt 60 unit for fixed field and rotation therapy. , 1959, The American journal of roentgenology, radium therapy, and nuclear medicine.

[64]  Dirk Verellen,et al.  Breathing-synchronized irradiation using stereoscopic kV-imaging to limit influence of interplay between leaf motion and organ motion in 3D-CRT and IMRT: Dosimetric verification and first clinical experience , 2006 .

[65]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[66]  D. Verellen,et al.  Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region. , 1997, International journal of radiation oncology, biology, physics.

[67]  Anne Traynor,et al.  Feasibility report of image guided stereotactic body radiotherapy (IG-SBRT) with tomotherapy for early stage medically inoperable lung cancer using extreme hypofractionation , 2006, Acta oncologica.

[68]  M van Herk,et al.  A liquid ionisation detector for digital radiography of therapeutic megavoltage photon beams. , 1985, Physics in medicine and biology.

[69]  M van Herk,et al.  Optimization of automatic portal image analysis. , 1995, Medical physics.

[70]  L. Antonuk Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research. , 2002, Physics in medicine and biology.

[71]  J. Cox,et al.  Weekly localization films and detection of field placement errors. , 1978, International journal of radiation oncology, biology, physics.

[72]  M. Murphy An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgery. , 1997, Medical physics.

[73]  C C Ling,et al.  Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality. , 2000, International journal of radiation oncology, biology, physics.

[74]  T E Schultheiss,et al.  A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer. , 1999, International journal of radiation oncology, biology, physics.

[75]  Hypofractionation reduces the therapeutic ratio in early glottic carcinoma. , 1988, International journal of radiation oncology, biology, physics.

[76]  Hassan Mostafavi,et al.  Development of a new linear accelerator mounted with dual X-Ray fluoroscopy using amorphous silicon flat panel X-Ray sensors to detect a gold seed in a tumor at real treatment position , 2001 .

[77]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[78]  Frank Van den Heuvel,et al.  Clinical application of a repositioning scheme, using gold markers and electronic portal imaging. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[79]  D. Verellen,et al.  Phase II study of preoperative helical tomotherapy for rectal cancer. , 2008, International journal of radiation oncology, biology, physics.

[80]  Daniel M Aebersold,et al.  Daily organ tracking in intensity-modulated radiotherapy of prostate cancer using an electronic portal imaging device with a dose saving acquisition mode. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[81]  M Goitein,et al.  Precise positioning of patients for radiation therapy. , 1982, International journal of radiation oncology, biology, physics.

[82]  Maarten L P Dirkx,et al.  Dosimetric pre-treatment verification of IMRT using an EPID; clinical experience. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[83]  G T Chen,et al.  A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy. , 1996, International journal of radiation oncology, biology, physics.

[84]  Dirk Verellen,et al.  Quality assurance of a system for improved target localization and patient set-up that combines real-time infrared tracking and stereoscopic X-ray imaging. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[85]  M Kono,et al.  Intrafractional tumor position stability during computed tomography (CT)-guided frameless stereotactic radiation therapy for lung or liver cancers with a fusion of CT and linear accelerator (FOCAL) unit. , 2000, International journal of radiation oncology, biology, physics.

[86]  U Oppitz,et al.  Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frame. , 2000, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[87]  J. Fowler,et al.  Selective boosting of tumor subvolumes. , 2000, International journal of radiation oncology, biology, physics.

[88]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[89]  K. Nakagawa,et al.  An integrated radiotherapy treatment system and its clinical application. , 1987, Radiation medicine.

[90]  M. V. van Herk,et al.  Anatomy changes in radiotherapy detected using portal imaging. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[91]  R E Vijlbrief,et al.  Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device. , 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[92]  J. Balter,et al.  Imaging and alignment for image-guided radiation therapy. , 2007, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[93]  Frank Van den Heuvel,et al.  Independent verification of ultrasound based image-guided radiation treatment, using electronic portal imaging and implanted gold markers. , 2003, Medical physics.

[94]  Masahiro Hiraoka,et al.  Development of a four-dimensional image-guided radiotherapy system with a gimbaled X-ray head. , 2006, International journal of radiation oncology, biology, physics.

[95]  S. Gambhir Molecular imaging of cancer with positron emission tomography , 2002, Nature Reviews Cancer.

[96]  J. Leong,et al.  Use of digital fluoroscopy as an on-line verification device in radiation therapy. , 1986, Physics in medicine and biology.

[97]  G K Svensson,et al.  Ultrasound image fusion for external beam radiotherapy for prostate cancer. , 1996, International journal of radiation oncology, biology, physics.

[98]  I. Tannock,et al.  Repopulation of cancer cells during therapy: an important cause of treatment failure , 2005, Nature Reviews Cancer.

[99]  A F HOLLOWAY A localising device for a rotating cobalt therapy unit. , 1958, The British journal of radiology.

[100]  J Moseley,et al.  A semiautomatic method for registration of portal images. , 1994, Medical physics.

[101]  Ping Xia,et al.  Low-dose megavoltage cone-beam CT for radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[102]  K. Bratengeier,et al.  Precision required for dose-escalated treatment of spinal metastases and implications for image-guided radiation therapy (IGRT). , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[103]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[104]  D Verellen,et al.  Risk assessment of radiation-induced malignancies based on whole-body equivalent dose estimates for IMRT treatment in the head and neck region. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[105]  D. Verellen,et al.  Assessment of secondary patient motion induced by automated couch movement during on-line 6 dimensional repositioning in prostate cancer treatment. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[106]  Importing measured field fluences into the treatment planning system to validate a breathing synchronized DMLC-IMRT irradiation technique. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[107]  A L Boyer,et al.  Investigation of an FFT-based correlation technique for verification of radiation treatment setup. , 1991, Medical physics.

[108]  Hiroshi Onishi,et al.  A new irradiation unit constructed of self-moving gantry-CT and linac. , 2003, International journal of radiation oncology, biology, physics.

[109]  Thomas Guerrero,et al.  Comparison of outcomes for patients with medically inoperable Stage I non-small-cell lung cancer treated with two-dimensional vs. three-dimensional radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[110]  T R Mackie,et al.  Quality assurance of a helical tomotherapy machine. , 2004, Physics in medicine and biology.

[111]  G. Fletcher Hypofractionation: lessons from complications. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[112]  D. Jaffray,et al.  Advances in image-guided radiation therapy. , 2007, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[113]  B W Raaymakers,et al.  Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field , 2007, Physics in medicine and biology.

[114]  D. Low Image-Guided IMRT. , 2006, Medical physics.