Fluorescence imaging of cardiac propagation: spectral properties and filtering of optical action potentials.

Fluorescence imaging using voltage-sensitive dyes is an important tool for studying electrical propagation in the heart. Yet, the low amplitude of the voltage-sensitive component in the fluorescence signal and high acquisition rates dictated by the rapid propagation of the excitation wave front make it difficult to achieve recordings with high signal-to-noise ratios. Although spatially and temporally filtering the acquired signals has become de facto one of the key elements of optical mapping, there is no consensus regarding their use. Here we characterize the spatiotemporal spectra of optically recorded action potentials and determine the distortion produced by conical filters of different sizes. On the basis of these findings, we formulate the criteria for rational selection of filter characteristics. We studied the evolution of the spatial spectra of the propagating wave front after epicardial point stimulation of the isolated, perfused right ventricular free wall of the pig heart stained with di-4-ANEPPS. We found that short-wavelength (<3 mm) spectral components represent primarily noise and surface features of the preparation (coronary vessels, fat, and connective tissue). The time domain of the optical action potential spectrum also lacks high-frequency components (>100 Hz). Both findings are consistent with the reported effect of intrinsic blurring caused by light scattering inside the myocardial wall. The absence of high-frequency spectral components allows the use of aggressive low-pass spatial and temporal filters without affecting the optical action potential morphology. We show examples where the signal-to-noise ratio increased up to 150 with <3% distortion. A generalization of our approach to the rational filter selection in various applications is discussed.

[1]  J P Wikswo,et al.  Quatrefoil Reentry in Myocardinm: An Optical Imaging Study of the Induction Mechanism , 1999, Journal of cardiovascular electrophysiology.

[2]  D. Field,et al.  Visual sensitivity, blur and the sources of variability in the amplitude spectra of natural scenes , 1997, Vision Research.

[3]  A. Garfinkel,et al.  Effects of amiodarone on wave front dynamics during ventricular fibrillation in isolated swine right ventricle. , 2002, American journal of physiology. Heart and circulatory physiology.

[4]  A. Panfilov,et al.  Nonstationary vortexlike reentrant activity as a mechanism of polymorphic ventricular tachycardia in the isolated rabbit heart. , 1995, Circulation.

[5]  R. Gray,et al.  What Exactly Are Optically Recorded “Action Potentials”? , 1999, Journal of cardiovascular electrophysiology.

[6]  R. Guyton,et al.  Coronary sinus pressure and arterial venting do not affect retrograde cardioplegia distribution. , 1994, The Annals of thoracic surgery.

[7]  J Jalife,et al.  Distribution of excitation frequencies on the epicardial and endocardial surfaces of fibrillating ventricular wall of the sheep heart. , 2000, Circulation research.

[8]  G. Salama,et al.  Optical Imaging of the Heart , 2004, Circulation research.

[9]  Igor Efimov,et al.  Optical Mapping of Cardiac Stimulation: Fluorescent Imaging with a Photodiode Array , 2002 .

[10]  Frederick J Vetter,et al.  Optical Action Potential Upstroke Morphology Reveals Near-Surface Transmural Propagation Direction , 2005, Circulation research.

[11]  N. Grzywacz,et al.  Power spectra and distribution of contrasts of natural images from different habitats , 2003, Vision Research.

[12]  G. Salama,et al.  A naphthyl analog of the aminostyryl pyridinium class of potentiometric membrane dyes shows consistent sensitivity in a variety of tissue, cell, and model membrane preparations , 1992, The Journal of Membrane Biology.

[13]  P D Wolf,et al.  Existence of both fast and slow channel activity during the early stages of ventricular fibrillation. , 1992, Circulation research.

[14]  R. Ideker,et al.  Mechanism of Ventricular Defibrillation for Near-Defibrillation Threshold Shocks: A Whole-Heart Optical Mapping Study in Swine , 2001, Circulation.

[15]  Lawrence O'Gorman,et al.  Practical Algorithms for Image Analysis with CD-ROM , 2008 .

[16]  William L. Ditto,et al.  A method for visualization of ventricular fibrillation: Design of a cooled fiberoptically coupled image intensified CCD data acquisition system incorporating wavelet shrinkage based adaptive filtering. , 1998, Chaos.

[17]  José Jalife,et al.  Synthesis of voltage-sensitive fluorescence signals from three-dimensional myocardial activation patterns. , 2003, Biophysical journal.

[18]  Jian Huang,et al.  Restitution Properties During Ventricular Fibrillation in the In Situ Swine Heart , 2004, Circulation.

[19]  Candido Cabo,et al.  Quantitative cardiac electrophysiology , 2002 .

[20]  Robert W. Mills,et al.  Phase Shifting Prior to Spatial Filtering Enhances Optical Recordings of Cardiac Action Potential Propagation , 2001, Annals of Biomedical Engineering.

[21]  I R Efimov,et al.  Evidence of Three‐Dimensional Scroll Waves with Ribbon‐Shaped Filament as a Mechanism of Ventricular Tachycardia in the Isolated Rabbit Heart , 1999, Journal of cardiovascular electrophysiology.

[22]  A. Skanes,et al.  Spatiotemporal periodicity during atrial fibrillation in the isolated sheep heart. , 1998, Circulation.

[23]  V. Fast,et al.  Microscopic conduction in cultured strands of neonatal rat heart cells measured with voltage-sensitive dyes. , 1993, Circulation research.