Diffracting aperture based differential phase contrast for scanning X-ray microscopy.

It is demonstrated that in a zone plate based scanning X-ray microscope, used to image low absorbing, heterogeneous matter at a mesoscopic scale, differential phase contrast (DPC) can be implemented without adding any additional optical component to the normal scheme of the microscope. The DPC mode is simply generated by an appropriate positioning and alignment of microscope apertures. Diffraction from the apertures produces a wave front with a non-uniform intensity. The signal recorded by a pinhole photo diode located in the intensity gradient is highly sensitive to phase changes introduced by the specimen to be recorded. The feasibility of this novel DPC technique was proven with the scanning X-ray microscope at the ID21 beamline of the European Synchrotron Radiation facility (ESRF) operated at 6 keV photon energy. We observe a differential phase contrast, similar to Nomarski's differential interference contrast for the light microscope, which results in a tremendous increase in image contrast of up to 20 % when imaging low absorbing specimen.

[1]  Burkhard Kaulich,et al.  Differential interference contrast x-ray microscopy with twin zone plates. , 2003, Journal of the Optical Society of America. A, Optics, image science, and vision.

[2]  J. Susini,et al.  Differential interference contrast x-ray microscopy with twin zone plates , 2002 .

[3]  Burkhard Kaulich,et al.  Differential interference contrast x-ray microscopy with submicron resolution , 2001 .

[4]  J. Susini,et al.  Current status of the Scanning X-ray Microscope at the ESRF , 2000 .

[5]  J. Susini,et al.  The X-ray microscopy facility at the ESRF: A status report , 2000 .

[6]  J. Susini,et al.  High-efficiency multilevel zone plates for keV X-rays , 1999, Nature.

[7]  D. Joyeux,et al.  An interferometric determination of the refractive part of optical constants for carbon and silver across soft X-ray absorption edges , 1999 .

[8]  G. Schneider,et al.  Cryo X-ray microscopy with high spatial resolution in amplitude and phase contrast. , 1998, Ultramicroscopy.

[9]  D. Joyeux,et al.  Applications of wavefront division interferometers in soft x rays , 1995 .

[10]  Henry N. Chapman,et al.  Applications of a CCD detector in scanning transmission x‐ray microscope , 1995 .

[11]  Ping-chin Cheng,et al.  X-Ray Microscopy: Instrumentation and Biological Applications , 1987 .

[12]  U. Bonse,et al.  AN X‐RAY INTERFEROMETER , 1965 .

[13]  Amruth N. Kumar,et al.  Links , 1999, INTL.

[14]  B. Niemann,et al.  Differential Phase Contrast X-Ray Microscopy , 1998 .

[15]  G. Schmahl,et al.  Proposal for a Phase Contrast X-ray Microscope , 1987 .