Presurgical brain mapping in epilepsy using simultaneous EEG and functional MRI at ultra-high field: feasibility and first results

ObjectivesThe aim of this study was to demonstrate that eloquent cortex and epileptic-related hemodynamic changes can be safely and reliably detected using simultaneous electroencephalography (EEG)–functional magnetic resonance imaging (fMRI) recordings at ultra-high field (UHF) for clinical evaluation of patients with epilepsy.Materials and methodsSimultaneous EEG–fMRI was acquired at 7 T using an optimized setup in nine patients with lesional epilepsy. According to the localization of the lesion, mapping of eloquent cortex (language and motor) was also performed in two patients.ResultsDespite strong artifacts, efficient correction of intra-MRI EEG could be achieved with optimized artifact removal algorithms, allowing robust identification of interictal epileptiform discharges. Noise-sensitive topography-related analyses and electrical source localization were also performed successfully. Localization of epilepsy-related hemodynamic changes compatible with the lesion were detected in three patients and concordant with findings obtained at 3 T. Local loss of signal in specific regions, essentially due to B1 inhomogeneities were found to depend on the geometric arrangement of EEG leads over the cap.ConclusionThese results demonstrate that presurgical mapping of epileptic networks and eloquent cortex is both safe and feasible at UHF, with the benefits of greater spatial resolution and higher blood-oxygenation-level-dependent sensitivity compared with the more traditional field strength of 3 T.

[1]  K. Uğurbil,et al.  Microvascular BOLD contribution at 4 and 7 T in the human brain: Gradient‐echo and spin‐echo fMRI with suppression of blood effects , 2003, Magnetic resonance in medicine.

[2]  Kenneth Hugdahl,et al.  Realignment parameter-informed artefact correction for simultaneous EEG–fMRI recordings , 2009, NeuroImage.

[3]  L. Lemieux,et al.  With or without spikes: localization of focal epileptic activity by simultaneous electroencephalography and functional magnetic resonance imaging. , 2011, Brain : a journal of neurology.

[4]  Christoph M. Michel,et al.  Spatiotemporal Analysis of Multichannel EEG: CARTOOL , 2011, Comput. Intell. Neurosci..

[5]  L. Lemieux,et al.  Recording of EEG during fMRI experiments: Patient safety , 1997, Magnetic resonance in medicine.

[6]  B. Condon,et al.  Investigation of the factors responsible for burns during MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[7]  Alberto Leal,et al.  Reduction of EEG artefacts induced by vibration in the MR-environment , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[8]  Karen J. Mullinger,et al.  Identifying the sources of the pulse artefact in EEG recordings made inside an MR scanner , 2013, NeuroImage.

[9]  Tobias Kober,et al.  MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field , 2010, NeuroImage.

[10]  M. Murray,et al.  EEG source imaging , 2004, Clinical Neurophysiology.

[11]  M. Fukunaga,et al.  Negative BOLD-fMRI Signals in Large Cerebral Veins , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[12]  Christoph M. Michel,et al.  The spatio-temporal mapping of epileptic networks: Combination of EEG–fMRI and EEG source imaging , 2009, NeuroImage.

[13]  S. Debener,et al.  Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[14]  João Jorge,et al.  Towards high-quality simultaneous EEG-fMRI at 7T: Detection and reduction of EEG artifacts due to head motion , 2015, NeuroImage.

[15]  Arno Villringer,et al.  Internal ventilation system of MR scanners induces specific EEG artifact during simultaneous EEG-fMRI , 2013, NeuroImage.

[16]  Emery N. Brown,et al.  Motion and Ballistocardiogram Artifact Removal for Interleaved Recording of EEG and EPs during MRI , 2002, NeuroImage.

[17]  Lukas Breuer,et al.  Methods for pulse artefact reduction: Experiences with EEG data recorded at 9.4T static magnetic field , 2014, Journal of Neuroscience Methods.

[18]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.

[19]  Qingfei Luo,et al.  Influence of dense‐array EEG cap on fMRI signal , 2012, Magnetic resonance in medicine.

[20]  Christoph M. Michel,et al.  Electrical neuroimaging based on biophysical constraints , 2004, NeuroImage.

[21]  Siegfried Trattnig,et al.  Differential functional benefits of ultra highfield MR systems within the language network , 2014, NeuroImage.

[22]  Winston X. Yan,et al.  Physical modeling of pulse artefact sources in simultaneous EEG/fMRI , 2009, Human brain mapping.

[23]  R. Kreis,et al.  Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences , 1999, Magnetic resonance in medicine.

[24]  Ravi S. Menon,et al.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[25]  S. Debener,et al.  Effects of simultaneous EEG recording on MRI data quality at 1.5, 3 and 7 tesla. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[26]  R. Turner,et al.  Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI , 1993, Magnetic resonance in medicine.

[27]  C. Michel,et al.  Propagation of Interictal Epileptiform Activity Can Lead to Erroneous Source Localizations: A 128-Channel EEG Mapping Study , 2003, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[28]  M. Verhoye,et al.  Reduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI data. , 2000, Magnetic resonance imaging.

[29]  Tobias Kober,et al.  SA2RAGE: A new sequence for fast B1+‐mapping , 2012, Magnetic resonance in medicine.

[30]  Christoph M. Michel,et al.  Pulse Artifact Detection in Simultaneous EEG–fMRI Recording Based on EEG Map Topography , 2014, Brain Topography.

[31]  Karl J. Friston,et al.  Movement‐Related effects in fMRI time‐series , 1996, Magnetic resonance in medicine.

[32]  Frédéric Grouiller,et al.  A comparative study of different artefact removal algorithms for EEG signals acquired during functional MRI , 2007, NeuroImage.

[33]  Jean-Michel Morel,et al.  A Review of Image Denoising Algorithms, with a New One , 2005, Multiscale Model. Simul..

[34]  Fritz Schick,et al.  Whole-body MRI at high field: technical limits and clinical potential , 2005, European Radiology.

[35]  Siegfried Trattnig,et al.  Clinical fMRI: Evidence for a 7 T benefit over 3 T , 2011, NeuroImage.

[36]  C. Michel,et al.  Noninvasive language mapping in patients with epilepsy or brain tumors. , 2013, Neurosurgery.

[37]  Oliver Kraff,et al.  Subjective acceptance of 7 Tesla MRI for human imaging , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[38]  Bettina Sorger,et al.  Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact , 2007, NeuroImage.

[39]  Graeme D. Jackson,et al.  Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings , 2007, NeuroImage.

[40]  Rami K. Niazy,et al.  Removal of FMRI environment artifacts from EEG data using optimal basis sets , 2005, NeuroImage.

[41]  Christoph M. Michel,et al.  Simultaneous EEG–fMRI at ultra-high field: Artifact prevention and safety assessment , 2015, NeuroImage.

[42]  Christoph M. Michel,et al.  Combination of EEG–fMRI and EEG source analysis improves interpretation of spike-associated activation networks in paediatric pharmacoresistant focal epilepsies , 2009, NeuroImage.

[43]  Sabine Van Huffel,et al.  Removal of BCG artifacts from EEG recordings inside the MR scanner: A comparison of methodological and validation-related aspects , 2010, NeuroImage.

[44]  Jean Gotman,et al.  Reproducibility of interictal EEG‐fMRI results in patients with epilepsy , 2011, Epilepsia.

[45]  J. Belliveau,et al.  Metallic electrodes and leads in simultaneous EEG‐MRI: Specific absorption rate (SAR) simulation studies , 2004, Bioelectromagnetics.

[46]  Peter G. Morris,et al.  fMRI at 1.5, 3 and 7 T: Characterising BOLD signal changes , 2009, NeuroImage.

[47]  Giorgio Bonmassar,et al.  EEG/(f)MRI measurements at 7 Tesla using a new EEG cap (“InkCap”) , 2006, NeuroImage.

[48]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.