Assessment of the Accuracy of Stereotactic Target Localization Using Magnetic Resonance Imaging: A Phantom Study

Magnetic resonance imaging is a valuable technique for brain target visualization and localization for stereotactically guided open surgery, stereotactic biopsy, or stereotactic radiosurgery. However, questions remain regarding the extent of image distortion (caused mainly by inhomogeneity of the constant magnetic field induced by the imaged object and nonlinearities in the gradient fields) and its effect on the accuracy of stereotactic localization. A phantom study has been carried out to assess the accuracy of stereotactic localization using spin echo T1-weighted, T2-weighted, proton density, and gradient echo three-dimensional magnetic resonance imaging. A special cubical perspex phantom with the insert of an array of 81 solid perspex rods (2 mm in diameter and spaced 15 mm) was constructed and attached to the base of a Leksell sterotactic frame. The deviations between sterotactic coordinates based on magnetic resonance imaging determined in the treatment planning system and real geometrical position given by the construction of an array of perspex rods within the phantom were evaluated in a series of axial and coronal images for the above-mentioned four sequences. No dependence of the extent of deviations on the investigation sequences was observed. The image orientation and spatial position of measured points in the volume of cubical phantom were also not significantly influenced. The maximal deviation was observed for T1-weighted coronal study, 1.8 mm in the Z coordinate. However, average deviations in all of the eight performed studies were less than or equal to 0.6 mm. Phantom measurements proved minimal distortion effects for all investigated modalities and therefore no special corrections were applied for stereotactic localization.

[1]  W. J. Lorenz,et al.  Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations. , 1992, Magnetic resonance imaging.

[2]  M Kessler,et al.  Image correlation of MRI and CT in treatment planning for radiosurgery of intracranial vascular malformations. , 1991, International journal of radiation oncology, biology, physics.

[3]  R D Bucholz,et al.  Variables affecting the accuracy of stereotactic localization using computerized tomography. , 1993, Journal of neurosurgery.

[4]  Quality assessment of magnetic resonance stereotactic localization for Gamma Knife radiosurgery. , 1995, Stereotactic and functional neurosurgery.

[5]  L Walton,et al.  Stereotactic localization using magnetic resonance imaging. , 1995, Stereotactic and functional neurosurgery.

[6]  R. Meuli,et al.  Assessment of MR image deformation for stereotactic neurosurgery using a tagging sequence. , 1994, AJNR. American journal of neuroradiology.

[7]  L. Schad,et al.  Three dimensional image correlation of CT, MR, and PET studies in radiotherapy treatment planning of brain tumors. , 1987, Journal of computer assisted tomography.

[8]  U Haverkamp,et al.  Comparison of imaging accuracy at different MRI units based on phantom measurements. , 1995, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  Alfred L. Horowitz MRI Physics for Radiologists: A Visual Approach , 1993 .

[10]  G. Glover,et al.  Characterization of spatial distortion in magnetic resonance imaging and its implications for stereotactic surgery. , 1994, Neurosurgery.

[11]  V Sturm,et al.  Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy. , 1987, Journal of computer assisted tomography.

[12]  E Kanal,et al.  A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination. , 1992, Neurosurgery.

[13]  L Walton,et al.  A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system. , 1996, Neurosurgery.

[14]  S Napel,et al.  Quantifying MRI geometric distortion in tissue , 1994, Magnetic resonance in medicine.