Temperature Sensing Optimization for Home Thermostat Retrofit

Most existing residential buildings adopt one single-zone thermostat to control the heating of rooms with different thermal conditions. This solution often provides poor thermal comfort and inefficient use of energy. The current market proposes smart thermostats and thermostatic radiator valves (TRVs) as cheap and relatively easy-to-install retrofit solutions. These systems provide increased freedom of installation, due to the use of wireless communication; however, the uncertainty of the measured air temperature, considering the thermostat placement, could impact the final heating performance. This paper presents a sensing optimization approach for a home thermostat, in order to determine the optimal retrofit configuration to reduce the sensing uncertainty, thus achieving the required comfort level and minimizing the retrofit’s payback period. The methodology was applied to a real case study—a dwelling located in Italy. The measured data and a simulation model were used to create different retrofit scenarios. Among these, the optimal scenario was achieved through thermostat repositioning and a setpoint of 21 °C, without the use of TRVs. Such optimization provided an improvement of control performance due to sensor location, with consequent energy savings of 7% (compared to the baseline). The resulting payback period ranged from two and a half years to less than a year, depending on impact of the embedded smart thermostat algorithms.

[1]  D. Vuuren,et al.  Modeling global residential sector energy demand for heating and air conditioning in the context of climate change , 2009 .

[2]  Thomas Kasper,et al.  Turning up the heat on obsolete thermostats: A simulation-based comparison of intelligent control approaches for residential heating systems , 2017 .

[3]  Marianne F. Touchie,et al.  Residential smart thermostat use: An exploration of thermostat programming, environmental attitudes, and the influence of smart controls on energy savings , 2021 .

[4]  Xu Han,et al.  An optimization platform based on coupled indoor environment and HVAC simulation and its application in optimal thermostat placement , 2019, Energy and Buildings.

[5]  Francesco D’Ettorre,et al.  On the assessment and control optimisation of demand response programs in residential buildings , 2020, Renewable and Sustainable Energy Reviews.

[6]  Fergus Nicol,et al.  Comfort and energy use in buildings—Getting them right , 2007 .

[7]  Paul Raftery,et al.  A review of methods to match building energy simulation models to measured data , 2014 .

[8]  Verena Tiefenbeck,et al.  Field Evaluation of Programmable Thermostats , 2012 .

[9]  Tobias W. Rehm,et al.  Smart Home Field Test – Investigation of Heating Energy Savings in Residential Buildings , 2018, 2018 7th International Energy and Sustainability Conference (IESC).

[10]  David M. Auslander,et al.  Multi-Sensor Single-Actuator Control of HVAC Systems , 2002 .

[11]  Gian Marco Revel,et al.  A tool for the optimal sensor placement to optimize temperature monitoring in large sports spaces , 2016 .

[12]  Kiyoshi Takahashi,et al.  Global climate targets and future consumption level : an evaluation of the required GHG intensity , 2016 .

[13]  Edgar G. Hertwich,et al.  Global Climate targets and future consumption level: An evaluation of the required GHG intensity , 2013 .

[14]  Enrico Fabrizio,et al.  Impact of low investment strategies for space heating control: Application of thermostatic radiators valves to an old residential building , 2015 .

[15]  Paul Cooper,et al.  Existing building retrofits: Methodology and state-of-the-art , 2012 .

[16]  A. Marian,et al.  Conditions for a cost-effective application of smart thermostat systems in residential buildings , 2020 .

[17]  Jin Woo Moon,et al.  Thermostat strategies impact on energy consumption in residential buildings , 2011 .

[18]  Constantinos A. Balaras,et al.  Actual energy savings from the use of thermostatic radiator valves in residential buildings – Long term field evaluation , 2017 .