A new sensor for detection of coolant leakage in nuclear power plants using off-axis integrated cavity output spectroscopy

Abstract A new sensor based on laser absorption spectroscopy was developed for the detection of coolant leakage which may happen in pressurized heavy water reactor (PHWR). Off-axis integrated output spectroscopy (OA-ICOS) technique was adopted for developing a simple and robust sensor with sufficient sensitivity. Leak events could be monitored by detecting a small change in semi-heavy water (HDO) concentration induced by the exchange reaction of leaked heavy water (D 2 O) with light water (H 2 O). From the results of feasibility tests, we have shown that the measured area of absorption features was linearly correlated with HDO concentration, and the minimum detectable change of HDO concentration with the developed sensor was evaluated as 3.2 ppm. This new sensor is expected to be a reliable and promising device for the detection of coolant leakage since it has some advantages on real-time monitoring and early detection for nuclear safety.

[1]  J. G. Kim,et al.  The Temperature Dependence of the Quantum Transition Properties of the Quasi-two-dimensional System in Quasi-two-dimensional Semiconductors , 2010 .

[2]  B. Bechtold,et al.  New generation of monitoring systems with on-line diagnostics , 1995 .

[3]  I. Hwang,et al.  New leak detection technique using ceramic humidity sensor for water reactors , 2001 .

[4]  G. Lim,et al.  Laser-based sensor for a coolant leak detection in a nuclear reactor , 2010 .

[5]  James J. Scherer,et al.  cw Integrated cavity output spectroscopy , 1999 .

[6]  J G Anderson,et al.  Ultrasensitive absorption spectroscopy with a high-finesse optical cavity and off-axis alignment. , 2001, Applied optics.

[7]  F. Keutsch,et al.  Ultrasensitive near-infrared integrated cavity output spectroscopy technique for detection of CO at 1.57 microm: new sensitivity limits for absorption measurements in passive optical cavities. , 2006, Applied optics.

[8]  A. Knohl,et al.  Water vapor δ 2 H and δ 18 O measurements using off-axis integrated cavity output spectroscopy , 2009 .

[9]  A. O’Keefe,et al.  Cavity ring‐down optical spectrometer for absorption measurements using pulsed laser sources , 1988 .

[10]  Rudy Peeters,et al.  Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy , 1998 .

[11]  K. Ko,et al.  Reduction of Fringe Noise in a Multi-pass Absorption Cell by Using the Wavelength Modulation Technique , 2010 .

[12]  Kyeongsook Kim,et al.  Feasibility of Fourier Transform (FT) Infrared spectroscopy for monitoring heavy water concentration in pressurized heavy water reactor , 2003 .

[13]  Frank K Tittel,et al.  Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection. , 2004, Applied optics.

[14]  U. Kunze Experience with the acoustic leakage monitoring system ALUES in 17 vVER plants , 1999 .

[15]  Herwig Kogelnik,et al.  Off-Axis Paths in Spherical Mirror Interferometers , 1964 .