Multi-channel metabolic imaging, with SENSE reconstruction, of hyperpolarized [1-(13)C] pyruvate in a live rat at 3.0 tesla on a clinical MR scanner.

We report metabolic images of (13)C, following injection of a bolus of hyperpolarized [1-(13)C] pyruvate in a live rat. The data were acquired on a clinical scanner, using custom coils for volume transmission and array reception. Proton blocking of all carbon resonators enabled proton anatomic imaging with the system body coil, to allow for registration of anatomic and metabolic images, for which good correlation was achieved, with some anatomic features (kidney and heart) clearly visible in a carbon image, without reference to the corresponding proton image. Parallel imaging with sensitivity encoding was used to increase the spatial resolution in the SI direction of the rat. The signal to noise ratio in was in some instances unexpectedly high in the parallel images; variability of the polarization among different trials, plus partial volume effects, are noted as a possible cause of this.

[1]  Ileana Hancu,et al.  Accelerated spectroscopic imaging of hyperpolarized C‐13 pyruvate using SENSE parallel imaging , 2009, NMR in biomedicine.

[2]  S. Nelson Analysis of volume MRI and MR spectroscopic imaging data for the evaluation of patients with brain tumors , 2001, Magnetic resonance in medicine.

[3]  Jan H. Ardenkjær-Larsen,et al.  Molecular imaging with endogenous substances , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[4]  Spatial dependence of a differential shading artifact in images from coil arrays with reactive cross-talk at 1.5 T. , 2001, Journal of magnetic resonance.

[5]  K. Derby,et al.  The loss of signal to noise due to imperfect isolation between the channels of a quadrature nuclear magnetic resonance probe , 1991 .

[6]  E. M. Jones,et al.  Microwave Filters, Impedance-Matching Networks, and Coupling Structures , 1980 .

[7]  S. Sugiura,et al.  A dual‐tuned probe and multiband receiver front end for X‐nucleus spectroscopy with proton scout imaging in vivo , 1989, Magnetic resonance in medicine.

[8]  Jiafeng Zhou MICROWAVE FILTERS , 2001, Microwave Circuit Design.

[9]  John M Pauly,et al.  Double spin-echo sequence for rapid spectroscopic imaging of hyperpolarized 13C. , 2007, Journal of magnetic resonance.

[10]  Christopher J. Hardy,et al.  Electronic decoupling of surface-coil receivers for NMR imaging and spectroscopy , 1986 .

[11]  John M Pauly,et al.  Design of flyback echo‐planar readout gradients for magnetic resonance spectroscopic imaging , 2005, Magnetic resonance in medicine.

[12]  Adolf Pfefferbaum,et al.  Application of subsecond spiral chemical shift imaging to real‐time multislice metabolic imaging of the rat in vivo after injection of hyperpolarized 13C1‐pyruvate , 2009, Magnetic resonance in medicine.

[13]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[14]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[15]  John M Pauly,et al.  Hyperpolarized C‐13 spectroscopic imaging of the TRAMP mouse at 3T—Initial experience , 2007, Magnetic resonance in medicine.

[16]  S J Kohler,et al.  Imaging considerations for in vivo 13C metabolic mapping using hyperpolarized 13C‐pyruvate , 2009, Magnetic resonance in medicine.

[17]  S. Banerjee,et al.  Partially Parallel MR Spectroscopic Imaging of Gliomas at 3T , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.