Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and image-guided surgical templates: accuracy in human cadavers.

OBJECTIVES In edentulous patients, accurate and stable positioning of a surgical template is impeded by the mobile mucosal tissue. The objective was to evaluate the accuracy of flapless computer-assisted template-guided surgery in an edentulous human cadaver specimen using three fixed oral reference points (FRP) for fixation of the registration mouthpiece and the consecutive surgical template. MATERIAL AND METHODS Oral implants were planned on the computed tomography (CT) of an edentulous human cadaver specimen. Surgical templates have been fabricated using a multipurpose navigation system. Both the registration mouthpiece and consecutive surgical template were supported via three FRP. Study implants were inserted through the guide sleeves and the accuracy was evaluated on a post-surgical CT of the cadaver jaws fused with the pre-surgical planning CT. A Matlab script enabled comparison of the planned surgical path with the study implants. RESULTS In five maxillary and three mandibular edentulous human cadaver specimens, a total of 51 implants (35 implants in the maxilla and 16 implants in the mandible) have been placed. The mean+/-standard deviation total error (Euclidean distance)/lateral error (normal deviation) were 1.1+/-0.6/0.7+/-0.5 mm at the implant base and 1.2+/-0.7/0.9+/-0.7 mm at the implant tip. The mean angular error was 2.8+/-2.2 degrees. CONCLUSIONS Flapless surgery based on FRP-supported image-guided surgical templates may provide similar accuracy as reported for tooth-supported surgical templates or surgical navigation.

[1]  Hom-lay Wang,et al.  Flapless implant surgery in the esthetic region: advantages and precautions. , 2007, The International journal of periodontics & restorative dentistry.

[2]  Franz Kainberger,et al.  Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy. , 2003, Clinical oral implants research.

[3]  Steven D Sudbrink Computer-guided implant placement with immediate provisionalization: a case report. , 2005, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[4]  Daniel van Steenberghe,et al.  Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures: a cohort study of consecutive patients. , 2007, The Journal of prosthetic dentistry.

[5]  Markus B Blatz,et al.  Precision for computer-guided implant placement: using 3D planning software and fixed intraoral reference points. , 2007, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[6]  R. Ewers,et al.  Basic research and 12 years of clinical experience in computer-assisted navigation technology: a review. , 2005, International journal of oral and maxillofacial surgery.

[7]  W. Birkfellner,et al.  Prospective randomized clinical comparison of 2 dental implant navigation systems. , 2007, The International journal of oral & maxillofacial implants.

[8]  Jean Loup Coudert,et al.  Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study. , 2003, The International journal of oral & maxillofacial implants.

[9]  G. Carlsson,et al.  What are the prevalence and incidence of tooth loss in the adult and elderly population in Europe? , 2007, Clinical oral implants research.

[10]  Reinhilde Jacobs,et al.  Imaging technique selection for the preoperative planning of oral implants: a review of the literature. , 2002, Clinical implant dentistry and related research.

[11]  R. Triplett,et al.  Interactive imaging for implant planning, placement, and prosthesis construction. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[12]  Carsten Westendorff,et al.  Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a synthetic edentulous lower jaw model. , 2005, Clinical oral implants research.

[13]  Werner Jaschke,et al.  In vitro accuracy of a novel registration and targeting technique for image-guided template production. , 2005, Clinical oral implants research.

[14]  Markus B Blatz,et al.  Application of interim fixed reference points to maintain the occlusal vertical dimension: a technique for immediate loading protocols in the edentulous mandible. , 2006, The Journal of prosthetic dentistry.

[15]  Paul Suetens,et al.  A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. , 2002, The International journal of oral & maxillofacial implants.

[16]  Eric Blanchet,et al.  Effect of flapless surgery on pain experienced in implant placement using an image-guided system. , 2006, The International journal of oral & maxillofacial implants.

[17]  Michael Figl,et al.  Navigated flapless transmucosal implant placement in the mandible: a pilot study in 20 patients. , 2007, The International journal of oral & maxillofacial implants.

[18]  A. Wagner,et al.  Computer-guided flapless placement and immediate loading of four conical screw-type implants in the edentulous mandible. , 2007, Clinical oral implants research.

[19]  Rudolf Seemann,et al.  Computer-aided navigation in dental implantology: 7 years of clinical experience. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[20]  Georg Eggers,et al.  Accuracy of image-guided implantology. , 2005, Clinical oral implants research.

[21]  G. Schiroli,et al.  Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. , 2009, The International journal of oral & maxillofacial implants.

[22]  Guillaume Champleboux,et al.  Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. , 2002, Clinical oral implants research.

[23]  Harel Simon,et al.  Use of transitional implants to support a surgical guide: enhancing the accuracy of implant placement. , 2002, The Journal of prosthetic dentistry.

[24]  Franz Kainberger,et al.  Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible. , 2002, Clinical oral implants research.

[25]  Werner Jaschke,et al.  Use of a surgical navigation system for CT-guided template production. , 2007, The International journal of oral & maxillofacial implants.

[26]  Ilser Turkyilmaz,et al.  Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. , 2008, Journal of periodontology.

[27]  David P Sarment,et al.  Stereolithographic surgical templates for placement of dental implants in complex cases. , 2003, The International journal of periodontics & restorative dentistry.

[28]  Abbas Azari,et al.  A novel stereolithographic surgical guide template for planning treatment involving a mandibular dental implant. , 2008, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[29]  Filip Schutyser,et al.  A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. , 2005, Clinical implant dentistry and related research.

[30]  Gerlig Widmann,et al.  Accuracy in computer-aided implant surgery--a review. , 2006, The International journal of oral & maxillofacial implants.

[31]  Reinhilde Jacobs,et al.  E.A.O. guidelines fo the use of diagnostic imaging in implant dentistry. A consensus workshop organized by the European Association for Osseointegration in Trinity College Dublin. , 2002, Clinical oral implants research.

[32]  Patricia R Cury,et al.  Clinical application of stereolithographic surgical guides for implant placement: preliminary results. , 2005, Journal of periodontology.

[33]  Computer-guided flapless transmucosal implant placement in the mandible: a new combination of two innovative techniques. , 2006, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[34]  S. Rosenstiel,et al.  Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[35]  Roland Weiger,et al.  Changes in oral health over a 10-yr period in Switzerland. , 2008, European journal of oral sciences.

[36]  Philippe B Tardieu,et al.  Computer-assisted implant placement. A case report: treatment of the mandible. , 2003, The International journal of oral & maxillofacial implants.

[37]  Thomas Rieger,et al.  Multipurpose navigation system-based concept for surgical template production. , 2009, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[38]  M. Strauss,et al.  Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems. , 2008, Clinical oral implants research.

[39]  M. Goldstein,et al.  Histologic evaluation of implants following flapless and flapped surgery: a study in canines. , 2006, Journal of periodontology.

[40]  Gwen Swennen,et al.  Navigated vs. conventional implant insertion for maxillary single tooth replacement. , 2004, Clinical oral implants research.

[41]  H. Iplikçioğlu,et al.  The use of computerized tomography for diagnosis and treatment planning in implant dentistry. , 2002, The Journal of oral implantology.

[42]  S. Holst,et al.  Clinical application of surgical fixation screws in implant prosthodontics--Part I: positioning of radiographic and surgical templates. , 2004, The Journal of prosthetic dentistry.