Successful Preliminary Walking Experiments on a Transtibial Amputee Fitted with a Powered Prosthesis

This paper presents the results of preliminary walking experiments on a transtibial amputee wearing a powered prosthesis. The prosthesis prototype serves as a proof-of-concept implementation for investigating the potential of pleated pneumatic artificial muscles to power a transtibial prosthesis. The device is equipped with pleated pneumatic artificial muscles, and tethered to a laboratory pressure source. The prosthesis is capable of providing the amputee with 100% of the required push-off torque and it can adapt its joint stiffness to the walking speed. This study supports the hypothesis that a powered transtibial prosthesis with adaptable stiffness might be beneficial to the amputee.

[1]  Blake Hannaford,et al.  Muscle-Like Pneumatic Actuators for Below-Knee Prostheses, , 2000 .

[2]  Matthew M. Williamson,et al.  Series elastic actuators , 1995, Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots.

[3]  Blake Hannaford,et al.  Development of Powered Prosthetic Lower Limb , 1998 .

[4]  J Perry,et al.  Efficiency of dynamic elastic response prosthetic feet. , 1993, Journal of rehabilitation research and development.

[5]  Richard A. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[6]  F. Steinberg,et al.  Prosthetic rehabilitation of geriatric amputee patients: a follow-up study. , 1985, Archives of physical medicine and rehabilitation.

[7]  Dirk Lefeber,et al.  The Concept and Design of Pleated Pneumatic Artificial Muscles , 2001 .

[8]  Hugh M. Herr,et al.  An ankle-foot emulation system for the study of human walking biomechanics , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[9]  J. Perry,et al.  Gait Analysis , 2024 .

[10]  S.K. Au,et al.  Powered Ankle-Foot Prosthesis for the Improvement of Amputee Ambulation , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Daniel P. Ferris,et al.  Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis. , 2006, Journal of biomechanics.

[12]  S. Naumann,et al.  ANALYSIS OF MECHANICAL AND METABOLIC FACTORS IN THE GAIT OF CONGENITAL BELOW KNEE AMPUTEES: A Comparison of the SACH and Seattle Feet , 1992, American journal of physical medicine & rehabilitation.

[13]  Thomas G. Sugar,et al.  The SPARKy (Spring Ankle With Regenerative Kinetics) Project: Design and Analysis of a Robotic Transtibial Prosthesis With Regenerative Kinetics , 2007 .

[14]  Alfred D. Grant Gait Analysis: Normal and Pathological Function , 2010 .

[15]  Hugh M. Herr,et al.  Powered ankle-foot prosthesis to assist level-ground and stair-descent gaits , 2008, Neural Networks.

[16]  M. Goldfarb,et al.  Design and energetic characterization of a proportional-injector monopropellant-powered actuator , 2006, IEEE/ASME Transactions on Mechatronics.

[17]  S. Gard,et al.  The human ankle during walking: implications for design of biomimetic ankle prostheses. , 2004, Journal of biomechanics.

[18]  J. Perry,et al.  Prosthetic weight acceptance mechanics in transtibial amputees wearing the Single Axis, Seattle Lite, and Flex Foot. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[19]  Bram Vanderborght,et al.  Exploiting adaptable passive behaviour to influence natural dynamics applied to legged robots , 2005, Robotica.

[20]  M. Goldfarb,et al.  Design, control, and energetic characterization of a solenoid-injected monopropellant-powered actuator , 2006, IEEE/ASME Transactions on Mechatronics.