Can concentric tube robots follow the leader?

Continuum robots have opened a broad array of applications to robotics in general, and the concentric tube continuum robots promise many benefits in medicine. Many people intuitively assume that these robots can deploy along a curved trajectory, in such a way that the curved shape of the robot's shaft remains unchanged as the tip progresses forward (i.e. “follow-the-leader” deployment). This capability would be useful in advancing along winding lumens (e.g. blood vessels, lung bronchi, etc.), as well as when the device is embedded in soft tissue and used as a steerable needle. However, in this paper we show that deploying in a follow-the-leader manner is not possible except in very special cases of tube precurvatures, combined with specific deployment sequences. We also show that follow-the-leader deployment is not possible even for many of the “simple” cases where one might intuitively expect it to be. Fortunately, useful special cases of perfect follow-the-leader behavior do exist, and we provide examples and describe the conditions that must be satisfied for this to be possible. We also study approximate follow-the-leader behavior, proposing a metric to quantify the similarity of a general deployment to a follow-the-leader deployment.

[1]  Robert J. Webster,et al.  Mechanics of Precurved-Tube Continuum Robots , 2009, IEEE Transactions on Robotics.

[2]  D. Caleb Rucker,et al.  A Geometrically Exact Model for Externally Loaded Concentric-Tube Continuum Robots , 2010, IEEE Transactions on Robotics.

[3]  Pierre E. Dupont,et al.  Design optimization of concentric tube robots based on task and anatomical constraints , 2011, 2011 IEEE International Conference on Robotics and Automation.

[4]  H. Choset,et al.  Highly articulated robotic probe for minimally invasive surgery , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Tomer Anor,et al.  Algorithms for design of continuum robots using the concentric tubes approach: A neurosurgical example , 2011, 2011 IEEE International Conference on Robotics and Automation.

[6]  Gregory S. Chirikjian,et al.  Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..

[7]  D. Caleb Rucker,et al.  The ACUSITT ultrasonic ablator: the first steerable needle with an integrated interventional tool , 2010, Medical Imaging.

[8]  Pierre E. Dupont,et al.  Stiffness Control of Surgical Continuum Manipulators , 2011, IEEE Transactions on Robotics.

[9]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[10]  Jessica Burgner,et al.  An Autoclavable Steerable Cannula Manual Deployment Device: Design and Accuracy Analysis. , 2012, Journal of medical devices.

[11]  D. Caleb Rucker,et al.  Parsimonious Evaluation of Concentric-Tube Continuum Robot Equilibrium Conformation , 2009, IEEE Transactions on Biomedical Engineering.

[12]  Pierre E. Dupont,et al.  Friction modeling in concentric tube robots , 2011, 2011 IEEE International Conference on Robotics and Automation.

[13]  Robert Rohling,et al.  Hand-held steerable needle device , 2003, IEEE/ASME Transactions on Mechatronics.

[14]  Robert J. Webster,et al.  Planning active cannula configurations through tubular anatomy , 2010, 2010 IEEE International Conference on Robotics and Automation.

[15]  D. Caleb Rucker,et al.  A bimanual teleoperated system for endonasal skull base surgery , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[16]  Gregory S. Chirikjian,et al.  Equilibrium Conformations of Concentric-tube Continuum Robots , 2010, Int. J. Robotics Res..

[17]  Kyle B. Reed,et al.  Robot-Assisted Needle Steering , 2011, IEEE Robotics & Automation Magazine.

[18]  Ron Alterovitz,et al.  Motion planning for concentric tube robots using mechanics-based models , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[19]  Howie Choset,et al.  A Follow-the-Leader Approach to Serpentine Robot Motion Planning , 1999 .

[20]  Koji Ikuta,et al.  Shape memory alloy servo actuator system with electric resistance feedback and application for active endoscope , 1988, Proceedings. 1988 IEEE International Conference on Robotics and Automation.

[21]  Robert J. Webster,et al.  Motion planning for active cannulas , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[22]  Robert J. Webster,et al.  Task-oriented design of concentric tube robots using mechanics-based models , 2012, 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[23]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.