A low-energy-consumption electroactive valveless hydrogel micropump for long-term biomedical applications.

Stimuli-responsive hydrogels have attracted considerable interest in the field of microfluidics due to their ability to transform electrical energy directly into mechanical work through swelling, bending, and other deformations. In particular, electroactive hydrogels hold great promise for biomedical micropumping applications such as implantable drug delivery systems. In such applications, energy consumption rate and durability are key properties. Here, we developed a valveless micropump system that utilizes a hydrogel as the main actuator, and tested its performance over 6 months of continuous operation. The proposed micropump system, powered by a single 1.5 V commercial battery, expended very little energy (less than 750 μWs per stroke) while pumping 0.9 wt% saline solution under a low voltage (less than 1 V), and remained fully functional after 6 months. CFD simulations were conducted to improve the microchannel geometry so as to minimize the backflow caused by the valveless mechanism of the system. Based on the simulation results, an asymmetric geometry and a stop post were introduced to enhance the pumping performance. To demonstrate the feasibility of the proposed system as a drug delivery pump, an anti-cancer drug (adriamycin) was perfused to human breast cancer cells (MCF-7) using the pump. The present study showed that the proposed system can operate continuously for long periods with low energy consumption, powered by a single 1.5 V battery, making it a promising candidate for an implantable drug delivery system.

[1]  Seoung Gil Yoon,et al.  Electrical sensitive behavior of poly(vinyl alcohol)/poly (diallyldimethylammonium chloride) IPN hydrogel , 2003 .

[2]  A. Hoffman Hydrogels for Biomedical Applications , 2001, Advanced drug delivery reviews.

[3]  Dominique Teyssié,et al.  Conducting polymer artificial muscle fibres: toward an open air linear actuation. , 2010, Chemical communications.

[4]  Nam-Trung Nguyen,et al.  MEMS-Micropumps: A Review , 2002 .

[5]  T. Boehm,et al.  Fibrinogen-Neutrophil Interactions in Response to fMLP and Porphyromonas gingivalis Fimbrial Peptides , 2006, Immunological investigations.

[6]  S. Hussey,et al.  Differential regulation of neutrophil chemotaxis to IL‐8 and fMLP by GM‐CSF: lack of direct effect of oestradiol , 2006, Immunology.

[7]  A. K. Agarwal,et al.  Adaptive liquid microlenses activated by stimuli-responsive hydrogels , 2006, Nature.

[8]  R. Hill,et al.  Electric-field-enhanced transport in polyacrylamide hydrogel nanocomposites. , 2007, Journal of colloid and interface science.

[9]  Y. Osada,et al.  A polymer gel with electrically driven motility , 1992, Nature.

[10]  Andrew A. O. Tay,et al.  A Low Cost Polymer Based Piezo-actuated Micropump For Drug Delivery System , 2004 .

[11]  Hua Li,et al.  Modeling and simulation of chemo-electro-mechanical behavior of pH-electric-sensitive hydrogel , 2007, Analytical and bioanalytical chemistry.

[12]  S. Murdan Electro-responsive drug delivery from hydrogels. , 2003, Journal of controlled release : official journal of the Controlled Release Society.

[13]  G. Whitesides,et al.  Soft lithography in biology and biochemistry. , 2001, Annual review of biomedical engineering.

[14]  Masaki Fuchiwaki,et al.  Planate conducting polymer actuator based on polypyrrole and its application , 2009 .

[15]  Y. Huang,et al.  Synergistic antitumor effect of TRAIL and adriamycin on the human breast cancer cell line MCF-7. , 2009, Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas.

[16]  F Solzbacher,et al.  Free swelling and confined smart hydrogels for applications in chemomechanical sensors for physiological monitoring. , 2009, Sensors and actuators. B, Chemical.

[17]  Anthony Guiseppi-Elie,et al.  Electroconductive hydrogels: synthesis, characterization and biomedical applications. , 2010, Biomaterials.

[18]  M. Madou,et al.  Genetically engineered protein in hydrogels tailors stimuli-responsive characteristics , 2005, Nature Materials.

[19]  M. Frisk,et al.  Biomimetic soft multifunctional miniature aquabots. , 2008, Small.

[20]  Y. Naka,et al.  A micropump driven by a polypyrrole‐based conducting polymer soft actuator , 2010 .

[21]  Jinn-Cherng Yang,et al.  Low Power Consumption PZT Actuated Micro-Pump , 2006, 2006 International Microsystems, Package, Assembly Conference Taiwan.

[22]  Robin H. Liu,et al.  Functional hydrogel structures for autonomous flow control inside microfluidic channels , 2000, Nature.

[23]  W. Yim,et al.  An artificial muscle actuator for biomimetic underwater propulsors , 2007, Bioinspiration & biomimetics.

[24]  Dermot Diamond,et al.  Performance characteristics of a polypyrrole modified polydimethylsiloxane (PDMS) membrane based microfluidic pump , 2008 .

[25]  Nam Seo Goo,et al.  Development of a Peristaltic Micropump for Bio-Medical Applications Based on Mini LIPCA , 2008, ArXiv.

[26]  Takashi Miyata,et al.  A reversibly antigen-responsive hydrogel , 1999, Nature.

[27]  Anuvat Sirivat,et al.  Electric field assisted transdermal drug delivery from salicylic acid-loaded polyacrylamide hydrogels , 2009, Drug delivery.

[28]  Wouter Olthuis,et al.  Stimulus-sensitive hydrogels and their applications in chemical (micro)analysis. , 2003, The Analyst.

[29]  Robin H. Liu,et al.  Microfluidic tectonics: a comprehensive construction platform for microfluidic systems. , 2000, Proceedings of the National Academy of Sciences of the United States of America.