The suitability of Tedlar bags for breath sampling in medical diagnostic research

Tedlar bags are tested for their suitability for breath sampling for medical diagnostic purposes. Proton-transfer reaction-mass spectrometry was used to monitor the changes in composition of various mixtures contained in custom-made black-layered Tedlar bags. Characteristic ions at m/z 88 and 95 amu reflect considerable pollution from the bag material. The pollutant found on m/z 88 amu is most probably N,N-dimethylacetamide, a latent solvent used in the production of Tedlar film. Gas composition losses during filling were found to range from 5 to 47%, depending on the compound. Once stored, the half-lives of methanol, acetaldehyde, acetone, isoprene, benzene, toluene and styrene were estimated between 5 and 13 days. Losses from breath samples (52 h after filling) were found to be less than 10%. No observable decrease was found for ethylene over 3 days, using laser-based photoacoustic detection. For the use of Tedlar bags, a standardized protocol is advised, where the time point of analysis is fixed for all samples and should be kept as close as possible to the time of sampling.

[1]  P. Monks,et al.  Proton-transfer reaction mass spectrometry. , 2009, Chemical reviews.

[2]  P. Scheepers,et al.  On-line monitoring of UV-induced lipid peroxidation products from human skin in vivo using proton-transfer reaction mass spectrometry , 2006 .

[3]  David Smith,et al.  A longitudinal study of methanol in the exhaled breath of 30 healthy volunteers using selected ion flow tube mass spectrometry, SIFT-MS , 2006, Physiological measurement.

[4]  David Smith,et al.  A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS , 2006, Physiological measurement.

[5]  David Smith,et al.  A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry. , 2006, Rapid communications in mass spectrometry : RCM.

[6]  P. Španěl,et al.  A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS) , 2006, Physiological measurement.

[7]  M. Alexander,et al.  On-line analysis of organic compounds in diesel exhaust using a proton transfer reaction mass spectrometer (PTR-MS) , 2005 .

[8]  T. Märk,et al.  Unambiguous identification of volatile organic compounds by proton-transfer reaction mass spectrometry coupled with GC/MS. , 2005, Analytical Chemistry.

[9]  Herbert Tilg,et al.  Headspace screening of fluid obtained from the gut during colonoscopy and breath analysis by proton transfer reaction-mass spectrometry: A novel approach in the diagnosis of gastro-intestinal diseases , 2005 .

[10]  T. Worthington,et al.  The proton transfer reaction mass spectrometer and its use in medical science: applications to drug assays and the monitoring of bacteria , 2004 .

[11]  Simona M. Cristescu,et al.  Trace gas detection from fermentation processes in apples; an intercomparison study between proton-transfer-reaction mass spectrometry and laser photoacoustics , 2004 .

[12]  Tianshu Wang,et al.  A selected ion flow tube study of the reactions of H3O+, NO+ and O2+• with some phenols, phenyl alcohols and cyclic carbonyl compounds in support of SIFT-MS and PTR-MS , 2004 .

[13]  X. Zhang,et al.  Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[14]  Peter Werle,et al.  Diode-Laser Sensors for In-Situ Gas Analysis , 2004 .

[15]  P. Scheepers,et al.  Pharmacokinetics of ethylene in man by on-line laser photoacoustic detection. , 2003, Toxicology and applied pharmacology.

[16]  C. N. Hewitt,et al.  The application of proton transfer reaction-mass spectrometry (PTR-MS) to the monitoring and analysis of volatile organic compounds in the atmosphere. , 2003, Journal of environmental monitoring : JEM.

[17]  R. Fall,et al.  Sensitivity and specificity of atmospheric trace gas detection by proton-transfer-reaction mass spectrometry , 2003 .

[18]  S. Jonsson,et al.  Quantification of volatile sulfur compounds in complex gaseous matrices by solid-phase microextraction. , 2002, Journal of chromatography. A.

[19]  R. Fall,et al.  Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling. , 2001, Journal of applied physiology.

[20]  M. Grasserbauer,et al.  Investigation of the storage stability of selected volatile sulfur compounds in different sampling containers. , 2001, Journal of chromatography. A.

[21]  P. Španěl,et al.  A new 'online' method to measure increased exhaled isoprene in end-stage renal failure. , 2001, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[22]  P. Crutzen,et al.  Emissions of volatile organic compounds from Quercus ilex L. measured by Proton Transfer Reaction Mass Spectrometry under different environmental conditions , 2000 .

[23]  Z. Zadák,et al.  Determination of isoprene in human expired breath using solid-phase microextraction and gas chromatography-mass spectrometry. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[24]  F. Biasioli,et al.  PTR-MS real time monitoring of the emission of volatile organic compounds during postharvest aging of berryfruit , 1999 .

[25]  F. Harren,et al.  On-line laser photoacoustic detection of ethene in exhaled air as biomarker of ultraviolet radiation damage of the human skin , 1999 .

[26]  T. Karl,et al.  Quantification of passive smoking using proton-transfer-reaction mass spectrometry , 1998 .

[27]  A. Hansel,et al.  On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research , 1998 .

[28]  Werner Lindinger,et al.  Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels , 1998 .

[29]  Yunje Kim,et al.  Gas chromatographic–mass spectrometric analysis of mercaptan odorants in liquefied petroleum gas and liquefied natural gas , 1997 .

[30]  R. Kelly,et al.  Sources of variability in cation analysis for a quantitative exfoliation corrosion resistance test , 1996 .

[31]  A. Hansel,et al.  Proton transfer reaction mass spectrometry (PTR-MS): propanol in human breath , 1996 .

[32]  Investigation of organic vapor losses to condensed water vapor in Tedlar bags used for exhaled-breath sampling. , 1996, American Industrial Hygiene Association journal.

[33]  A. Hansel,et al.  Acetonitrile and benzene in the breath of smokers and non-smokers investigated by proton transfer reaction mass spectrometry (PTR-MS) , 1995 .

[34]  C. Kneepkens,et al.  The potential of the hydrocarbon breath test as a measure of lipid peroxidation. , 1994, Free radical biology & medicine.

[35]  M. Phillips,et al.  Breath tests in medicine. , 1992, Scientific American.

[36]  M. Phillips,et al.  Method for the collection and analysis of volatile compounds in the breath. , 1991, Journal of chromatography.

[37]  E. Woltering,et al.  Laser photoacoustics: a novel method for ethylene determination in plant physiological studies. , 1989 .

[38]  Y. Lau Measurement of sulphur gases in ambient air , 1989, Environmental monitoring and assessment.

[39]  M. Phillips,et al.  A new highly sensitive assay for breath acetaldehyde: detection of endogenous levels in humans. , 1981, Analytical biochemistry.