Intramedullary Headless Screw Fixation of Metacarpal Fractures: A Radiographic Analysis for Optimal Screw Choice

Background: The purpose of this study was to investigate variations in radiographic metacarpal anatomy as it relates to intramedullary (IM) fixation of metacarpal fractures and to compare this anatomy with available headless screw dimensions. Methods: We radiographically analyzed posteroanterior and lateral (LAT) radiographs of 120 metacarpals across 30 patients without structural abnormalities. Primary outcomes included IM isthmus diameter, isthmus location, metacarpal cascade, and head entry point collinear with IM canal. Measurements were compared with a list of commercially available headless screws used for IM fixation. Results: The average largest isthmus diameter was in the small metacarpal (3.4 mm), followed by the index (2.8 mm), long (2.7 mm), and ring (2.7 mm) metacarpals. The average cascade angle between long and index, long and ring, and long and small metacarpals was 0°, 24°, and 27°, respectively. The appropriate head entry point ranged between 25% and 35% from the dorsal surface of the metacarpal head on a LAT view. The retrograde isthmus location of the index and long finger was 39.2 and 38.1 mm, respectively. Twenty-five screws from 7 manufacturers were analyzed with sizes ranging from 1.7 to 4.5 mm. Only 8 of 17 screws between 2.3 and 3.5 mm had a length range above 35 mm. Conclusions: Metacarpal head entry point and cascade angle can help identify the appropriate reduction with the guide pin starting point in the dorsal 25% to 35% of the metacarpal head. Surgeons should be mindful to choose the appropriate fixation system in light of the variations between metacarpal isthmus size, isthmus location, and available screw lengths.

[1]  P. Taub,et al.  Intramedullary Screw Fixation of Metacarpal Fractures Results in Excellent Functional Outcomes: A Literature Review , 2019, Plastic and reconstructive surgery.

[2]  P. Giovanoli,et al.  Retrograde fixation of metacarpal fractures with intramedullary cannulated headless compression screws. , 2018, Hand surgery & rehabilitation.

[3]  Brian K. Lee,et al.  Radiographic and Clinical Assessment of Intramedullary Nail Fixation for the Treatment of Unstable Metacarpal Fractures , 2018, Hand.

[4]  J. Couceiro,et al.  Intramedullary Screws versus Kirschner Wires for Metacarpal Fixation, Functional, and Patient-Related Outcomes , 2018, The Surgery Journal.

[5]  A. Weiss,et al.  Silicone Metacarpophalangeal Arthroplasty for Osteoarthritis: Long-Term Results. , 2017, The Journal of hand surgery.

[6]  O. Kennedy,et al.  Crossed K-Wires Versus Intramedullary Headless Screw Fixation of Unstable Metacarpal Neck Fractures: A Biomechanical Study. , 2018, The Iowa orthopaedic journal.

[7]  F. Dyrna,et al.  Headless Compression Screw Versus Kirschner Wire Fixation for Metacarpal Neck Fractures: A Biomechanical Study. , 2017, The Journal of hand surgery.

[8]  R. Romo-Rodríguez,et al.  [Minimal invasive osteosynthesis with cannulated screws in metacarpal fractures]. , 2017, Acta ortopedica mexicana.

[9]  Ji-Woong Kim,et al.  Open reduction and internal fixation for intraarticular fracture of metacarpal head , 2017, Der Orthopäde.

[10]  D. Tobert,et al.  Intramedullary Fixation of Metacarpal Fractures Using Headless Compression Screws , 2016, Journal of Hand and Microsurgery.

[11]  Pan Hu,et al.  Comparison of AO Titanium Locking Plate and Screw Fixation versus Anterograde Intramedullary Fixation for Isolated Unstable Metacarpal and Phalangeal Fractures , 2016, Orthopaedic surgery.

[12]  A. Ilyas,et al.  Metacarpal Neck Fractures: A Review of Surgical Indications and Techniques , 2016, Archives of trauma research.

[13]  O. Fajolu,et al.  Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K‐Wires and Plate‐Screw Constructs , 2015, Orthopaedic surgery.

[14]  Michael C. Doarn,et al.  Retrograde Headless Intramedullary Screw Fixation for Displaced Fifth Metacarpal Neck and Shaft Fractures: Short Term Results , 2015, Hand.

[15]  L. Cerezal,et al.  Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws. , 2015, The Journal of hand surgery.

[16]  D. Ruchelsman,et al.  Clinical outcomes of limited-open retrograde intramedullary headless screw fixation of metacarpal fractures. , 2014, The Journal of hand surgery.

[17]  W. Hammert,et al.  Metacarpal fractures: treatment and complications , 2014, Hand.

[18]  Peter G. Davison,et al.  Systematic review of the best evidence in intramedullary fixation for metacarpal fractures , 2013, Hand.

[19]  D. Ruchelsman,et al.  Quantitative 3-dimensional CT analyses of intramedullary headless screw fixation for metacarpal neck fractures. , 2013, The Journal of hand surgery.

[20]  D. Morsi,et al.  Sex determination by the length of metacarpals and phalanges: X-ray study on Egyptian population , 2013 .

[21]  Doaa A El Morsi,et al.  Sex determination by the length of metacarpals and phalanges: X-ray study on Egyptian population. , 2013, Journal of forensic and legal medicine.

[22]  B. Owens,et al.  Incidence of metacarpal fractures in the US population , 2012, Hand.

[23]  P. Liverneaux,et al.  Fifth metacarpal neck fracture fixation: Locking plate versus K-wire? , 2010, Orthopaedics & traumatology, surgery & research : OTSR.

[24]  M. Salzler,et al.  Intramedullary cannulated headless screw fixation of a comminuted subcapital metacarpal fracture: case report. , 2010, The Journal of hand surgery.

[25]  M. Bednar,et al.  Complications after the fractures of metacarpal and phalanges. , 2010, Hand clinics.

[26]  C. Eliopoulos,et al.  Sex determination using metacarpal biometric data from the Athens Collection. , 2009, Forensic science international.

[27]  D. McFadden,et al.  Sex and race differences in the relative lengths of metacarpals and metatarsals in human skeletons. , 2009, Early human development.

[28]  Allison E. Williams,et al.  Comparison of intramedullary nailing versus plate-screw fixation of extra-articular metacarpal fractures. , 2008, The Journal of hand surgery.

[29]  K. Chung,et al.  The frequency and epidemiology of hand and forearm fractures in the United States. , 2001, The Journal of hand surgery.

[30]  S. Kozin,et al.  Operative Treatment of Metacarpal and Phalangeal Shaft Fractures , 2000, The Journal of the American Academy of Orthopaedic Surgeons.

[31]  J. Capo,et al.  Metacarpal and phalangeal fractures in athletes. , 1998, Clinics in sports medicine.

[32]  T. Fischer,et al.  Use of a minicondylar plate for metacarpal and phalangeal periarticular injuries. , 1987, Clinical orthopaedics and related research.