Calibration of Elasto-Magnetic Sensors on In-Service Cable-Stayed Bridges for Stress Monitoring

The recent developments in measurement technology have led to the installation of efficient monitoring systems on many bridges and other structures all over the world. Nowadays, more and more structures have been built and instrumented with sensors. However, calibration and installation of sensors remain challenging tasks. In this paper, we use a case study, Adige Bridge, in order to present a low-cost method for the calibration and installation of elasto-magnetic sensors on cable-stayed bridges. Elasto-magnetic sensors enable monitoring of cable stress. The sensor installation took place two years after the bridge construction. The calibration was conducted in two phases: one in the laboratory and the other one on site. In the laboratory, a sensor was built around a segment of cable that was identical to those of the cable-stayed bridge. Then, the sample was subjected to a defined tension force. The sensor response was compared with the applied load. Experimental results showed that the relationship between load and magnetic permeability does not depend on the sensor fabrication process except for an offset. The determination of this offset required in situ calibration after installation. In order to perform the in situ calibration without removing the cables from the bridge, vibration tests were carried out for the estimation of the cables’ tensions. At the end of the paper, we show and discuss one year of data from the elasto-magnetic sensors. Calibration results demonstrate the simplicity of the installation of these sensors on existing bridges and new structures.

[1]  Seunghee Park,et al.  Real-Time NDE of Steel Cable Using Elasto-Magnetic Sensors Installed in a Cable Climbing Robot , 2011 .

[2]  George M. Lloyd,et al.  Magnetoelastic permeability measurement for stress monitoring in steel tendons and cables , 2000, Smart Structures.

[3]  Hiroshi Zui,et al.  Practical Formulas for Estimation of Cable Tension by Vibration Method , 1996 .

[4]  A. P,et al.  Mechanical Vibrations , 1948, Nature.

[5]  Yang Zhao,et al.  Steel stress monitoring sensor based on elasto-magnetic effect and using magneto-electric laminated composite , 2012 .

[6]  Ming L. Wang,et al.  MONITORING OF CABLE FORCES USING MAGNETO-ELASTIC SENSORS , 1999 .

[7]  J. E. Indacochea,et al.  Detection and Monitoring of Corrosion in Structural Carbon Steels Using Electromagnetic Sensors , 2008 .

[8]  J. E. Indacochea,et al.  Sensing creep evolution in 410 stainless steel by magnetic measurements , 2010 .

[9]  Ming L. Wang,et al.  ELASTO-MAGNETIC SENSOR UTILIZATION ON STEEL CABLE STRESS MEASUREMENT , 2002 .

[10]  Ming L. Wang,et al.  APPLICATION OF EM STRESS SENSORS IN LARGE STEEL CABLES , .

[11]  Ming L. Wang Long term health monitoring of post-tensioning box girder bridges , 2008 .

[12]  Weimin Chen,et al.  Study of a steel strand tension sensor with difference single bypass excitation structure based on the magneto-elastic effect , 2008 .

[13]  Ming L. Wang,et al.  Fast EM stress sensors for large steel cables , 2008, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[14]  Raimond Grimberg,et al.  Magnetic sensor used for the determination of fatigue state in ferromagnetic steels , 2000 .

[15]  Sunaryo Sumitro,et al.  Monitoring based maintenance utilizing actual stress sensory technology , 2005 .

[16]  R. A. Langman,et al.  The effect of stress on the magnetization of mild steel at moderate field strengths , 1985 .

[17]  B Kvasnica,et al.  Highly precise non-contact instrumentation for magnetic measurement of mechanical stress in low-carbon steel wires , 1996 .

[18]  David L. Atherton,et al.  CORRIGENDUM: Theory of the magnetisation process in ferromagnets and its application to the magnetomechanical effect , 1984 .

[19]  Ru Zhang,et al.  Smart elasto-magneto-electric (EME) sensors for stress monitoring of steel structures in railway infrastructures , 2011 .

[20]  Taehyo Park,et al.  Estimation of cable tension force using the frequency-based system identification method , 2007 .

[21]  George M. Lloyd,et al.  TED-AJ03-596 Effects of Temperature and Corrosion Thickness and Composition on Magnetic Measurements of Structural Steel Wires , 2004 .

[22]  A. Jarosevic,et al.  Magnetoelastic Method of Stress Measurement in Steel , 1999 .