Chemical Shift Artifact Correction in MREIT

Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

[1]  R. Henkelman,et al.  Sensitivity of magnetic-resonance current-density imaging , 1992 .

[2]  Eung Je Woo,et al.  Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging , 2008, Physiological measurement.

[3]  Jean A. Tkach,et al.  Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon technique , 1995, Journal of magnetic resonance imaging : JMRI.

[4]  Byung Il Lee,et al.  Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography. , 2003, Physics in medicine and biology.

[5]  Norbert J Pelc,et al.  Cramér–Rao bounds for three‐point decomposition of water and fat , 2005, Magnetic resonance in medicine.

[6]  Michael Markl,et al.  Multicoil Dixon chemical species separation with an iterative least‐squares estimation method , 2004, Magnetic resonance in medicine.

[7]  Q. Xiang,et al.  Water‐fat imaging with direct phase encoding , 1997, Journal of magnetic resonance imaging : JMRI.

[8]  G H Glover,et al.  Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction , 1991, Magnetic resonance in medicine.

[9]  Jingfei Ma Dixon techniques for water and fat imaging , 2008, Journal of magnetic resonance imaging : JMRI.

[10]  Jingfei Ma,et al.  Method for efficient fast spin echo Dixon imaging , 2002, Magnetic resonance in medicine.

[11]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[12]  Eung Je Woo,et al.  Local Harmonic $B_z$ Algorithm With Domain Decomposition in MREIT: Computer Simulation Study , 2008, IEEE Transactions on Medical Imaging.

[13]  Byung Il Lee,et al.  Noise analysis in magnetic resonance electrical impedance tomography at 3 and 11 T field strengths. , 2005, Physiological measurement.

[14]  Byung Il Lee,et al.  Measurement of induced magnetic flux density using injection current nonlinear encoding (ICNE) in MREIT. , 2007, Physiological measurement.

[15]  J. Felmlee,et al.  Proton MR chemical shift imaging using double and triple phase contrast acquisition methods. , 1989, Journal of computer assisted tomography.

[16]  R M Henkelman,et al.  Measurement of nonuniform current density by magnetic resonance. , 1991, IEEE transactions on medical imaging.

[17]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[18]  Ohin Kwon,et al.  Reconstruction of conductivity and current density images using only one component of magnetic field measurements , 2003, IEEE Transactions on Biomedical Engineering.

[19]  Y. Birgül,et al.  Use of the Magnetic Field Generated by the Internal Distribution of Injected Currents for Electrical Impedance Tomography (MR-EIT) , 1998 .

[20]  Eung Je Woo,et al.  Impedance tomography using internal current density distribution measured by nuclear magnetic resonance , 1994, Optics & Photonics.

[21]  Byung Il Lee,et al.  Conductivity imaging of canine brain using a 3 T MREIT system: postmortem experiments , 2007, Physiological measurement.

[22]  Eung Je Woo,et al.  CoReHA: conductivity reconstructor using harmonic algorithms for magnetic resonance electrical impedance tomography (MREIT) , 2009 .

[23]  J Szumowski,et al.  Two‐point Dixon technique for water‐fat signal decomposition with B0 inhomogeneity correction , 1997, Magnetic resonance in medicine.