Stability and Dynamic Analyses of Transmission Tower-Line Systems Subjected to Conductor Breaking

Ice loads exerted on the transmission line can increase the probability of conductor breaking, which will lead to the stability failure of transmission towers. In this paper, a transmission tower-line system is established for two towers and three span lines. Then the nonlinear static stability analysis and nonlinear dynamic stability analysis induced by the conductor breaking are carried out to obtain the load versus displacement curves, while studying the failure modes of the transmission tower-line system. Moreover, the ice load and initial eccentricity are considered in the numerical simulation. In addition, a parametric analysis is performed to investigate the influence of span, insulator length and initial tension force on the stability failure of the system. The results show that the dynamic instability will occur earlier than the static instability due to the dynamic impact effect and conductor breaking with ice loads can lead to the progressive collapse of the transmission tower-line system. Fina...

[1]  Gang Li,et al.  Fragility analysis and estimation of collapse status for transmission tower subjected to wind and rain loads , 2016 .

[2]  J.D. Mozer,et al.  Longitudinal load analysis of transmission line systems , 1977, IEEE Transactions on Power Apparatus and Systems.

[3]  William Wood,et al.  Broken Wire Tests on a Model Transmission Line System , 1981, IEEE Transactions on Power Apparatus and Systems.

[4]  Hong-Nan Li,et al.  The Numerical Analysis of Transmission Tower-Line System Wind-Induced Collapsed Performance , 2013 .

[5]  Li Li STUDY ON WIRE BREAKING-INDUCED VIBRATIONS OF ELECTRIC TRANSMISSION LINE , 2008 .

[6]  David B. Campbell Unbalanced Tensions in Transmission Lines , 1970 .

[7]  Steven A. Orszag,et al.  Stability and Lyapunov stability of dynamical systems: A differential approach and a numerical method , 1987 .

[8]  Jacob Aboudi,et al.  The Lyapunov exponents as a quantitative criterion for the dynamic buckling of composite plates , 2002 .

[9]  Hong-Nan Li,et al.  Progressive Collapse of Power Transmission Tower-Line System Under Extremely Strong Earthquake Excitations , 2016 .

[10]  Shen Shi-zhao Analysis method of dynamic stability of single-layer reticulated domes , 2003 .

[11]  Alain H. Peyrot,et al.  Dynamic Response of Ruptured Conductors in Transmission Lines , 1982, IEEE Transactions on Power Apparatus and Systems.

[12]  A. H. Shah,et al.  Galloping of Bundle Conductor , 2000 .

[13]  Bo Yan,et al.  Numerical Simulation Study on Jump Height of Iced Transmission Lines After Ice Shedding , 2013, IEEE Transactions on Power Delivery.

[14]  Matthew S. Mason,et al.  Comparison of Responses of Guyed and Freestanding Transmission Line Towers Under Conductor Breakage Loading , 2015 .

[15]  Xing Hai-jun Experiments and numerical simulation on the broken conductors in transmission lines , 2012 .

[16]  René Tinawi,et al.  Mathematical modeling of the transient response of electric transmission lines due to conductor breakage , 1987 .

[17]  Jun Lee,et al.  Longitudinal Loads From Broken Conductors and Broken Insulators and Their Effect on Transmission Lines , 1980, IEEE Transactions on Power Apparatus and Systems.

[18]  Liang Zheng DYNAMIC RESPONSE OF TRANSMISSION TOWER WITH RUPTURED WIRES , 2007 .

[19]  Li Zheng-liang Analysis of the Transmission Tower-line System in Heavy Ice Regions Subjected to Cable Rupture , 2010 .