Integrated Optic Surface Plasmon Resonance Measurements in a Borosilicate Glass Substrate

The surface plasmon resonance (SPR) technique is a well-known optical method that can be used to measure the refractive index of organic nano-layers adsorbed on a thin metal film. Although there are many configurations for measuring biomolecular interactions, SPR-based techniques play a central role in many current biosensing experiments, since they are the most suited for sensitive and quantitative kinetic measurements. Here we give some results from the analysis and numerical elaboration of SPR data from integrated optics experiments in a particular borosilicate glass, chosen for its composition offering the rather low refractive index of 1.4701 at 633 nm wavelength. These data regard the flow over the sensing region (metal window) of different solutions with refractive indexes in the range of interest (1.3÷1.5) for the detection of contaminants in aqueous solutions. After a discussion of the principles of SPR, of the metal window design optimization by means of optical interaction numerical modeling, and of waveguide fabrication techniques, we give a description of system setup and experimental results. Optimum gold film window thickness and width in this guided-wave configuration has been for the first time derived and implemented on an integrated optic prototype device. Its characterization is given by means of the real time waveguide output intensity measurements, which correspond to the interaction between the sensing gold thin film window and the flowing analyte. The SPR curve was subsequently inferred. Finally, a modified version of the device is reported, with channel waveguides arranged in a Y-junction optical circuit, so that laser source stability requirements are lowered by a factor of 85 dB, making possible the use of low cost sources in practical applications.

[1]  B. Eggins Chemical Sensors and Biosensors , 2002 .

[2]  Günter Gauglitz,et al.  Surface plasmon resonance sensors: review , 1999 .

[3]  Ramu V. Ramaswamy,et al.  Ion-exchanged glass waveguides: a review , 1988 .

[4]  J. C. Abanulo,et al.  Waveguide surface plasmon resonance sensor for electrochemically controlled surface reactions. , 2001, Applied optics.

[5]  J. Homola On the sensitivity of surface plasmon resonance sensors with spectral interrogation , 1997 .

[6]  A. Plant,et al.  Biotechnological applications of surface plasmon resonance , 1997 .

[7]  Radan Slavik,et al.  Single-mode optical fiber surface plasmon resonance sensor , 1999 .

[8]  B. Liedberg,et al.  Biosensing with surface plasmon resonance--how it all started. , 1995, Biosensors & bioelectronics.

[9]  D Wong,et al.  Chemical and Biochemical Sensing with Optical Fibers and Waveguides , 1997 .

[10]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[11]  J. Wilkinson,et al.  Waveguide surface plasmon resonance sensors , 1995 .

[12]  Ying Mu,et al.  An Optical Biosensor for Monitoring Antigen Recognition Based on Surface Plasmon Resonance Using Avidin-Biotin System , 2001 .

[13]  H. Raether Surface Plasmons on Smooth and Rough Surfaces and on Gratings , 1988 .

[14]  J. Homola Present and future of surface plasmon resonance biosensors , 2003, Analytical and bioanalytical chemistry.

[15]  Rebecca L Rich,et al.  Survey of the year 2003 commercial optical biosensor literature , 2005, Journal of molecular recognition : JMR.

[16]  Jiří Homola,et al.  A surface plasmon resonance based integrated optical sensor , 1997 .

[17]  K. Tsuei,et al.  The impact of the concept of a surface plasmon , 1995 .