Chiral analysis by mass spectrometry using the kinetic method in flow systems.

Chiral analysis is an important task of analytical chemistry. Besides separation techniques, mass spectrometry can be applied in this field. One mass spectrometric approach is based on Cooks' kinetic method. The method was successfully applied in a static system in which the concentration of the analyte as well as the chiral selector solution was constant during the experiment. The application of the kinetic method in dynamic systems (changing concentration of analyte) is presented. Such systems allow the speeding up of the analytical process (flow injection analysis (FIA)) or the use of the kinetic method for chiral detection after liquid chromatographic separation. The influence of the concentration of the components of the chiral selector solution as well as its flow rate on the recognition of enantiomers was evaluated. A new procedure for correction for the differences between ratio of enantiomers in the liquid phase and their observed ratio in the gas phase is also described. A significant improvement in accuracy using this procedure was achieved. Applicability of the method was demonstrated in the analysis of amino acids using FIA as well as HPLC/MS. After an achiral separation of leucine and isoleucine, chiral mass spectrometric detection was successfully used for enantiomeric recognition.

[1]  K. Lemr,et al.  Isomeric discrimination of arginine-containing dipeptides using electrospray ionization-ion trap mass spectrometry and the kinetic method , 2004, Journal of the American Society for Mass Spectrometry.

[2]  Maurizio Speranza,et al.  Enantioselectivity in gas-phase ion–molecule reactions , 2004 .

[3]  R. Cooks,et al.  Recognition and quantification of binary and ternary mixtures of isomeric peptides by the kinetic method: metal ion and ligand effects on the dissociation of metal-bound complexes , 2003, Journal of the American Society for Mass Spectrometry.

[4]  R. Cooks,et al.  Chiral analysis using the kinetic method with optimized fixed ligands: applications to some antibiotics. , 2003, Analytical chemistry.

[5]  W. Tao,et al.  Chiral analysis by MS. , 2003, Analytical chemistry.

[6]  W. Tao,et al.  Quantitative chiral analysis of sugars by electrospray ionization tandem mass spectrometry using modified amino acids as chiral reference compounds. , 2002, Analytical chemistry.

[7]  H. Aboul‐Enein,et al.  Recent applications of stereoselective chromatography. , 2002, Chirality.

[8]  J. Begley,et al.  Rapid enantiomeric quantification of an antiviral nucleoside agent (D,L-FMAU, 2'-fluoro-5-methyl-beta,D,L-arabinofurano-syluracil) by mass spectrometry. , 2001, Journal of medicinal chemistry.

[9]  P. Höglund,et al.  Clinical pharmacology of thalidomide , 2001, European Journal of Clinical Pharmacology.

[10]  R. Cooks,et al.  Differentiation and quantitation of isomeric dipeptides by low-energy dissociation of copper(II)-bound complexes , 2001, Journal of the American Society for Mass Spectrometry.

[11]  F. Gozzo,et al.  Mass spectrometric quantitation of chiral drugs by the kinetic method. , 2001, Analytical chemistry.

[12]  R. Cooks,et al.  Parallel Reactions for Enantiomeric Quantification of Peptides by Mass Spectrometry This work was supported by the U.S. Department of Energy, Office of Energy Research. W.A.T. acknowledges fellowship support from Triangle Pharmaceuticals. , 2001, Angewandte Chemie.

[13]  W. Tao,et al.  Copper(II)-Assisted Enantiomeric Analysis of D,L-Amino Acids Using the Kinetic Method: Chiral Recognition and Quantification in the Gas Phase , 2000 .

[14]  W. Tao,et al.  Rapid enantiomeric determination of α-hydroxy acids by electrospray ionization tandem mass spectrometry , 2000 .

[15]  W. Tao,et al.  Kinetic Resolution of d,l-Amino Acids Based on Gas-Phase Dissociation of Copper(II) Complexes. , 1999, Analytical chemistry.

[16]  M. Sawada Chiral recognition detected by fast atom bombardment mass spectrometry. , 1997, Mass spectrometry reviews.