Line power quality improvement for ESP systems using multi-pulse and active filter concepts

A simple way to improve the line power quality in Electrostatic Precipitator (ESP) applications by using both the characteristics of its electrical installation and the typical ESP high power supply is presented in this work. A multi-pulse system is built by selecting a combination of suitable MV/LV distribution transformers, preserving the simplicity and reliability of the typical ESP installation. In addition, processing only about 10% of the total system apparent power, shunts Active Filters (AFs) are placed on the low voltage side of the transformer (LV) for high order harmonic-current-mitigation (>7th harmonic). In case of imbalance in the transformer loading, the AFs can also act to adjust the current 5th and 7th harmonics, which are then effectively eliminated by the multipulse system. The theory presented in this work is verified experimentally by a 12 pulse system comprising two passive rectifiers and a designed 12kVAr active filter.

[1]  N. Grass Fuzzy logic-optimising IGBT inverter for electrostatic precipitators , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[2]  F. Blaabjerg,et al.  Evaluation of harmonic detection methods for active power filter applications , 2005, Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005..

[3]  Satoru Sone,et al.  Switching loss minimised space vector PWM method for IGBT three-level inverter , 1997 .

[4]  P. W. Lefley,et al.  Breathe easy [electrostatic precipitator] , 2006 .

[5]  P. Ranstad,et al.  Three elements resonant converter: the LCC topology by using MATLAB , 2000, 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018).

[6]  P. Ranstad,et al.  On cascading of the series loaded resonant converter , 2008, 2008 IEEE Power Electronics Specialists Conference.

[7]  M. Schweizer,et al.  Comparison and implementation of a 3-level NPC voltage link back-to-back converter with SiC and Si diodes , 2010, 2010 Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[8]  P. Ranstad,et al.  Design of a high power pulse voltage generator for electrostatic precipitators using magnetic switching technique , 1997, Proceedings of APEC 97 - Applied Power Electronics Conference.

[9]  Per Ranstad,et al.  On experiences of the application of high-frequency power converters for ESP energisation , 2004 .