Mathematical model of modified hybrid pump mechanism for cardiopulmonary resuscitation

BACKGROUND AND OBJECTIVE The "Cardiac pump theory" and "Thoracic pump theory" are representative theories of cardiopulmonary resuscitation (CPR) mechanisms. Based on these theories, many studies on mathematical modeling have been performed to help understand hemodynamics during CPR. However, there are parts that do not yet properly reflect the physiology of CPR. Therefore, this study aims to develop a lumped parameter model of CPR that can more accurately reflect the current CPR physiology. METHODS By adding compartments of the superior and inferior vena cava of the thoracic cavity to the existing CPR model, and the "Hybrid pump" mechanism was applied to simulate CPR. To compare the hemodynamics of the conventional CPR model and the developed CPR model, various conditions, such as active compression-decompression CPR with an impedance threshold valve device (ACD-CPR+ITV), head-up-tilt (HUT), and head-down-tilt (HDT), were simulated. The coronary perfusion pressure (CPP) was compared by modulating the compression ratio of the atrium and ventricle with the thoracic pump factor. RESULTS The result for the comparison of coronary blood flow showed that the existing model is predominant in the compression phase, whereas the developed model is dominant in the relaxation phase. ACD-CPR + ITV results showed that the CPP decreased by 5 % in the existing model, and increased by about 46 % in the developed model, revealing a distinct hemodynamic difference between the two models. Likewise, as a result of comparing the hemodynamic differences of the two models according to the changes in tilt angle, the HUT showed similar trends, while the HDT showed slightly different results. The CPP varied accordingly with the ratio of the ventricular and atrial thoracic pump factor. CONCLUSION Comparison of the hemodynamics with the existing model by simulating various conditions showed that the developed CPR model reflects the CPR physiology better. The model suggests that the hemodynamics may vary depending on the ventricle and atrium compression ratio. This study may provide an important basis for helping understand various situations and patient-specific hemodynamic characteristics during CPR through in-depth research, such as patient-specific model and parameter optimization.

[1]  A. Chalkias,et al.  Anatomical structures underneath the sternum in healthy adults and implications for chest compressions. , 2013, The American journal of emergency medicine.

[2]  Daniel A Beard,et al.  Understanding Guyton's venous return curves. , 2011, American journal of physiology. Heart and circulatory physiology.

[3]  S Scarsoglio,et al.  Impaired coronary blood flow at higher heart rates during atrial fibrillation: Investigation via multiscale modelling , 2019, Comput. Methods Programs Biomed..

[4]  R. Mark,et al.  Computational modeling of cardiovascular response to orthostatic stress. , 2002, Journal of applied physiology.

[5]  Charles F Babbs,et al.  Design of near-optimal waveforms for chest and abdominal compression and decompression in CPR using computer-simulated evolution. , 2006, Resuscitation.

[6]  K. Lurie,et al.  The Physiology of Cardiopulmonary Resuscitation , 2016, Anesthesia and analgesia.

[7]  J. Karemaker,et al.  Mathematical modeling of gravitational effects on the circulation: importance of the time course of venous pooling and blood volume changes in the lungs. , 2006, American journal of physiology. Heart and circulatory physiology.

[8]  Jesper Mehlsen,et al.  Patient-specific modelling of head-up tilt. , 2014, Mathematical medicine and biology : a journal of the IMA.

[9]  Trygve Sjoberg,et al.  Evaluation of coronary blood flow velocity during cardiac arrest with circulation maintained through mechanical chest compressions in a porcine model , 2011, BMC cardiovascular disorders.

[10]  A. Bardají,et al.  Understanding the Adverse Hemodynamic Effects of Serious Thoracic Injuries During Cardiopulmonary Resuscitation: A Review and Approach Based on the Campbell Diagram , 2019, Front. Physiol..

[11]  Wanchun Tang,et al.  Evolution of the stone heart after prolonged cardiac arrest. , 2002, Chest.

[12]  T. Xanthos,et al.  Use of the impedance threshold device in cardiopulmonary resuscitation. , 2010, World journal of cardiology.

[13]  C F Babbs,et al.  CPR techniques that combine chest and abdominal compression and decompression: hemodynamic insights from a spreadsheet model. , 1999, Circulation.

[14]  C. Bartolozzi,et al.  Blood flow maintenance by cardiac massage during cardiopulmonary resuscitation: Classical theories, newer hypotheses, and clinical utility of mechanical devices , 2018, Journal of the Intensive Care Society.

[15]  K. Lee,et al.  Compression of the left ventricular outflow tract during cardiopulmonary resuscitation. , 2009, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[16]  Hee Chan Kim,et al.  Computational simulation of passive leg-raising effects on hemodynamics during cardiopulmonary resuscitation , 2017, Comput. Methods Programs Biomed..

[17]  D. Sabiston,et al.  The physiology of external cardiac massage: high-impulse cardiopulmonary resuscitation. , 1984, Circulation.

[18]  M. Weisfeldt,et al.  Mechanisms of Blood Flow During Cardiopulmonary Resuscitation , 1980, Circulation.

[19]  Charles F Babbs,et al.  Effects of an impedance threshold valve upon hemodynamics in Standard CPR: studies in a refined computational model. , 2005, Resuscitation.

[20]  L. Geddes,et al.  Methods for Calculating Coronary Perfusion Pressure During CPR , 2009, Cardiovascular engineering.

[21]  J. Soar,et al.  Radiological assessment of the adult chest: implications for chest compressions. , 2006, Resuscitation.

[22]  K. Lurie,et al.  Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest. , 2000, Circulation.

[23]  R. Berne,et al.  REGULATION OF CORONARY BLOOD FLOW. , 1964, Physiological reviews.

[24]  T. J. Appleton,et al.  Simultaneous aortic, jugular bulb, and right atrial pressures during cardiopulmonary resuscitation in humans. Insights into mechanisms. , 1989, Circulation.

[25]  G. Ewy The mechanism of blood flow during chest compressions for cardiac arrest is probably influenced by the patient's chest configuration , 2018, Acute medicine & surgery.

[26]  J. Kramer-Johansen,et al.  Radiological assessment of chest compression point and achievable compression depth in cardiac patients , 2016, Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine.

[27]  T. J. Appleton,et al.  Coronary perfusion pressure and the return of spontaneous circulation in human cardiopulmonary resuscitation. , 1990, JAMA.

[28]  Aortic diameter and pressure-flow sequence identify mechanism of blood flow during external chest compression in dogs. , 1989, Journal of the American College of Cardiology.

[29]  A. Metzger,et al.  Tilting for perfusion: head-up position during cardiopulmonary resuscitation improves brain flow in a porcine model of cardiac arrest. , 2015, Resuscitation.

[30]  D. Sabiston,et al.  Effect of Cardiac Contraction on Coronary Blood Flow , 1957, Circulation.

[31]  Kyuseok Kim,et al.  Is the inter-nipple line the correct hand position for effective chest compression in adult cardiopulmonary resuscitation? , 2007, Resuscitation.

[32]  Monique L. Anderson,et al.  Part 6: Alternative Techniques and Ancillary Devices for Cardiopulmonary Resuscitation: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. , 2015, Circulation.

[33]  J. Karemaker,et al.  Abdominal counter pressure in CPR: what about the lungs? An in silico study. , 2012, Resuscitation.

[34]  M. Eriksen,et al.  Haemodynamic outcomes during piston-based mechanical CPR with or without active decompression in a porcine model of cardiac arrest , 2018, Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine.

[35]  A. Noordergraaf,et al.  The influence of nonlinear intra-thoracic vascular behaviour and compression characteristics on cardiac output during CPR. , 2011, Resuscitation.

[36]  K. Lurie,et al.  The effect of resuscitation position on cerebral and coronary perfusion pressure during mechanical cardiopulmonary resuscitation in porcine cardiac arrest model. , 2017, Resuscitation.