Material decomposition in an arbitrary number of dimensions using noise compensating projection

Purpose. Multi-energy CT (e.g., dual energy or photon counting) facilitates the identification of certain compounds via data decomposition. However, the standard approach to decomposition (i.e., solving a system of linear equations) yields negative values for material concentrations if—due to noise—a region of interest’s (ROI) CT values falls outside the boundary of CT values describing all possible pure or mixed basis materials. This may be addressed geometrically by projecting these points (the CT values of the ROI in question) onto the closest point on this boundary (the space of allowable CT values). However, when acquiring four (or more) energy volumes, the space bounded by three (or more) materials that may be found in the human body (either naturally or through injection) can be quite small. Noise may significantly limit the number of those voxels to be included within. Therefore, projection onto the boundary becomes an important option. But, projection in higher than three dimensional space is not possible with standard vector algebra: the cross-product is not defined. Methods. We describe a technique which employs Clifford algebra to perform projection in an arbitrary number of dimensions. Clifford algebra describes a manipulation of vectors that incorporates the concepts of addition, subtraction, multiplication, and division. Thereby, vectors may be operated on like scalars forming a true algebra. Results. We tested our approach on a phantom containing inserts of calcium, gadolinium, iodine, gold nanoparticles and mixtures of pairs thereof. Images were acquired on a prototype photon counting CT scanner under a range of energy threshold combinations. Comparisons of the accuracy of different threshold combinations versus ground truth are presented. Conclusions. Material decomposition is possible with three or more materials and four or more energy thresholds using Clifford algebra projection to mitigate noise.

[1]  Franz Pfeiffer,et al.  Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography. , 2017, Radiology.

[2]  Julien Milles,et al.  Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT , 2017, European Radiology.

[3]  C. McCollough,et al.  Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications. , 2015, Radiology.

[4]  M. Kachelriess,et al.  Performance of today's dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study. , 2015, Medical physics.

[5]  Peng He,et al.  Material Discrimination Based on K-edge Characteristics , 2013, Comput. Math. Methods Medicine.

[6]  K. Taguchi,et al.  Vision 20/20: Single photon counting x-ray detectors in medical imaging. , 2013, Medical physics.

[7]  Karl Stierstorfer,et al.  Multi-energy performance of a research prototype CT scanner with small-pixel counting detector , 2013, Medical Imaging.

[8]  Thorsten M. Buzug,et al.  Threshold optimization for efficient contrast imaging with quantum counting CT detectors , 2013, Medical Imaging.

[9]  L. MacDonald,et al.  Quantitative material characterization from multi-energy photon counting CT. , 2013, Medical physics.

[10]  Benjamin M Yeh,et al.  In vivo differentiation of complementary contrast media at dual-energy CT. , 2012, Radiology.

[11]  Axel Thran,et al.  An early investigation of ytterbium nanocolloids for selective and quantitative "multicolor" spectral CT imaging. , 2012, ACS nano.

[12]  Katsuyuki Taguchi,et al.  Material separation in x-ray CT with energy resolved photon-counting detectors , 2011, Medical Imaging.

[13]  S. Wildermuth,et al.  Dual- and multi-energy CT: approach to functional imaging , 2011, Insights into imaging.

[14]  Axel Thran,et al.  Note: This Copy Is for Your Personal, Non-commercial Use Only. to Order Presentation-ready Copies for Distribution to Your Colleagues or Clients, Contact Us at Www.rsna.org/rsnarights. Atherosclerotic Plaque Composition: Analysis with Multicolor Ct and Targeted Gold Nanoparticles 1 Materials and Met , 2022 .

[15]  Elmar Kotter,et al.  Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study. , 2010, Radiology.

[16]  A. Butler,et al.  Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE , 2010, European Radiology.

[17]  J. Dinten,et al.  Dual-Energy X-Ray Imaging: Benefits and Limits , 2007 .

[18]  Timo Berkus,et al.  Empirical dual energy calibration (EDEC) for cone-beam computed tomography. , 2007 .

[19]  Don Coppersmith,et al.  Matrix multiplication via arithmetic progressions , 1987, STOC.

[20]  W. Massey Cross products of vectors in higher dimensional euclidean spaces , 1983 .

[21]  Syen Jien Nik,et al.  Optimising the benefits of spectral x-ray imaging in material decomposition , 2013 .

[22]  D. J. H. Garling,et al.  Clifford Algebras: An Introduction: Introduction , 2011 .

[23]  Norbert J. Pelc,et al.  Sufficient Statistics as a Generalization of Binning in Spectral X-ray Imaging , 2011, IEEE Transactions on Medical Imaging.