Are external fixators as effective as volar plates in multi-fragmented radius distal intra-articular fractures (AO type C)?

[1]  Jae Hoon Lee,et al.  Complications associated with volar locking plate fixation for distal radius fractures in 1955 cases: A multicentre retrospective study , 2020, International Orthopaedics.

[2]  H. M. Özdemir,et al.  Comparison of three surgical methods in the treatment of intraarticular comminuted distal radius fractures: Volar locking plate, non-bridging external fixator, and bridging external fixator. , 2019, Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery.

[3]  X. Shao,et al.  Volar locking plate versus external fixation with optional additional K-wire for treatment of AO type C2/C3 fractures: a retrospective comparative study , 2019, Journal of Orthopaedic Surgery and Research.

[4]  Michael Thomas,et al.  Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis , 2018, The Journal of hand surgery, European volume.

[5]  Xuelei Wei,et al.  Is volar locking plate superior to external fixation for distal radius fractures? A comprehensive meta-analysis , 2018, Acta orthopaedica et traumatologica turcica.

[6]  M. Rongières Is the external fixator yet useful for treating fractures of the distal radius? , 2018, European Journal of Orthopaedic Surgery & Traumatology.

[7]  Q. Liu,et al.  Complications following open reduction and internal fixation versus external fixation in treating unstable distal radius fractures: Grading the evidence through a meta-analysis. , 2017, Orthopaedics & traumatology, surgery & research : OTSR.

[8]  G. Baek,et al.  A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures. , 2015, The Journal of hand surgery.

[9]  Sanjay Meena,et al.  Fractures of Distal Radius: An Overview , 2014, Journal of family medicine and primary care.

[10]  G. Baek,et al.  Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report , 2014, Clinics in orthopedic surgery.

[11]  J. Dias,et al.  Complications after volar locking plate fixation of distal radius fractures. , 2014, Injury.

[12]  G. Marco,et al.  Is it really necessary to restore radial anatomic parameters after distal radius fractures? , 2014, Injury.

[13]  E. Schemitsch,et al.  External fixation versus open reduction with plate fixation for distal radius fractures: a meta-analysis of randomised controlled trials. , 2013, Injury.

[14]  H. Kvernmo,et al.  Treatment of distal radius fractures. , 2013, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke.

[15]  L. Kucuk,et al.  Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures , 2014, European Journal of Orthopaedic Surgery & Traumatology.

[16]  M. Paavola,et al.  Värttinäluun distaalisten murtumien nykyhoito , 2012 .

[17]  R. Arora,et al.  A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. , 2011, The Journal of bone and joint surgery. American volume.

[18]  H. Abbaszadegan,et al.  Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year , 2011, Acta orthopaedica.

[19]  T. Messer,et al.  Complications of Volar Plate Fixation for Managing Distal Radius Fractures , 2009, The Journal of the American Academy of Orthopaedic Surgeons.

[20]  Блажо Боев,et al.  MAKEDONSKA AKADEMIJA NA NAUKITE I UMETNOSTITE , 2009 .

[21]  M. Walsh,et al.  Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial. , 2008, The Journal of bone and joint surgery. British volume.

[22]  M. Rizzo,et al.  Contemporary evaluation and treatment of distal radius fractures. , 2007, Hand clinics.

[23]  Edgar Erdfelder,et al.  G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences , 2007, Behavior research methods.

[24]  S. Trigg Functional Outcome of Unstable Distal Radius Fractures: ORIF With a Volar Fixed-Angle Tine Plate Versus External FixationWright TW, Horodyski MB, Smith DW (Univ of Florida, Gainesville; Univ of Texas School of Medicine, Houston) J Hand Surg [Am] 30A:289–299, 2005§ , 2006 .

[25]  K. Chung,et al.  A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. , 2005, The Journal of hand surgery.

[26]  T. Wright,et al.  Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation. , 2005, The Journal of hand surgery.

[27]  M. Swiontkowski,et al.  Consistency of AO fracture classification for the distal radius. , 1996, The Journal of bone and joint surgery. British volume.

[28]  F. C. King,et al.  Treatment of comminuted distal radius fractures: an approach based on pathomechanics. , 1994, Orthopedics.

[29]  Z. Yangb,et al.  Complications following open reduction and internal fixation versus external fixation in treating unstable distal radius fractures: Grading the evidence through a meta-analysis , 2022 .