Detect of Escherichia coli O157:H7 in ground beef samples using piezoelectric excited millimeter-sized cantilever (PEMC) sensors.
暂无分享,去创建一个
Shu-I Tu | Raj Mutharasan | G. Campbell | R. Mutharasan | J. Uknalis | S. Tu | Gossett A Campbell | Joe Uknalis
[1] P. Irwin,et al. A 6×6 drop plate method for simultaneous colony counting and MPN enumeration of Campylobacter jejuni, Listeria monocytogenes, and Escherichia coli , 2003 .
[2] L. Slutsker,et al. Escherichia coli O157 and Salmonella Infections Associated with Sprouts in California, 19961998 , 2001, Annals of Internal Medicine.
[3] Raj Mutharasan,et al. Detection of Bacillus anthracis spores and a model protein using PEMC sensors in a flow cell at 1 mL/min. , 2006, Biosensors & bioelectronics.
[4] Raj Mutharasan,et al. Escherichia coli O157:H7 detection limit of millimeter-sized PZT cantilever sensors is 700 cells/mL. , 2005, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.
[5] A. Gehring,et al. IMMUNO‐MAGNETIC BEAD MASS TRANSPORT AND CAPTURE EFFICIENCY AT LOW TARGET CELL DENSITIES IN PHOSPHATE‐BUFFERED SALINE1 , 2002 .
[6] Raj Mutharasan,et al. Detection of pathogen Escherichia coli O157:H7 using self-excited PZT-glass microcantilevers. , 2005, Biosensors & bioelectronics.
[7] Genomic analysis using pulsed-field gel electrophoresis of Escherichia coli O157: H7 isolated from dairy calves during the United State National Dairy Heifer Evaluation Project (1992-1992). , 1996, Veterinary microbiology.
[8] H Wang,et al. An immuno-capturing and concentrating procedure forEscherichia coliO157:H7 and its detection by epifluorescence microscopy , 1998 .
[9] Shu-I Tu,et al. THE CAPTURE OF ESCHERICHIA COLI O157:H7 FOR LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR (LAPS) USING TWO DIFFERENT TYPES OF MAGNETIC BEADS1 , 2002 .
[10] Shu-I Tu,et al. THE USE OF TIME‐RESOLVED FLUOROIMMUNOASSAY TO SIMULTANEOUSLY DETECT ESCHERICHIA COLI O157:H7, SALMONELLA ENTERICA SEROVAR TYPHIMURIUM AND SALMONELLA ENTERICA SEROVAR ENTERIDITIS IN FOODS1 , 2007 .
[11] Y. Zhao,et al. Influence of surface stress on frequency of microcantilever-based biosensors , 2004 .
[12] Shu-I Tu,et al. FACTORS AFFECTING THE BACTERIAL CAPTURE EFFICIENCY OF IMMUNO BEADS: A COMPARISON BETWEEN BEADS WITH DIFFERENT SIZE AND DENSITY1 , 2003 .
[13] Linda S. L. Yu,et al. THE USE OF STREPTAVIDIN COATED MAGNETIC BEADS FOR DETECTING PATHOGENIC BACTERIA BY LIGHT ADDRESSABLE POTENTIOMETRIC SENSOR (LAPS) , 2000 .
[14] A. E. Greenberg,et al. Standard methods for the examination of water and wastewater : supplement to the sixteenth edition , 1988 .