Fiber optic monitoring of carbamate pesticides using porous glass with covalently bound chlorophenol red.
暂无分享,去创建一个
F. Baldini | M. Moreno-Bondi | A. Falai | F Baldini | M C Moreno-Bondi | M. Marazuela | M P Xavier | B Vallejo | M D Marazuela | A Falai | B. Vallejo | M. P. Xavier
[1] Félix Pariente,et al. Determination of Organophosphorus and Carbamate Pesticides Using a Piezoelectric Biosensor , 1998 .
[2] D. Barceló,et al. Comparison of different clean-up procedures for the determination of N-methylcarbamate insecticides in vegetable matrices by high-performance liquid chromatography with UV detection , 1998 .
[3] R Narayanaswamy,et al. Fibre-optic pesticide biosensor based on covalently immobilized acetylcholinesterase and thymol blue. , 1997, Talanta: The International Journal of Pure and Applied Analytical Chemistry.
[4] A. Amirav,et al. Pesticide analysis with the pulsed-flame photometer detector and a direct sample introduction device. , 1997, Analytical chemistry.
[5] A. N. Díaz,et al. Sol-gel cholinesterase biosensor for organophosphorus pesticide fluorimetric analysis , 1997 .
[6] Salvador Alegret,et al. Determination of organophosphorus and carbamate pesticides using a biosensor based on a polishable, 7,7,8,8-tetracyanoquino-dimethane-modified, graphite—epoxy biocomposite , 1997 .
[7] M. Mascini,et al. Determination of anticholinesterase pesticides in real samples using a disposable biosensor , 1997 .
[8] Kathrin Stein,et al. Flow injection analysis of paraoxon with the use of an immobilized acetylcholinesterase reactor , 1996 .
[9] D. Barceló,et al. On-line sample handling strategies for the trace-level determination of pesticides and their degradation products in environmental waters , 1995 .
[10] G. Palleschi,et al. Evaluation of the use of free and immobilised acetylcholinesterase for paraoxon detection with an amperometric choline oxidase based biosensor , 1995 .
[11] Félix Pariente,et al. Amperometric flow-through biosensor for the determination of pesticides , 1995 .
[12] Ursula Bilitewski,et al. Characterisation of inhibitors of acetylcholinesterase by an automated amperometric flow-injection system , 1995 .
[13] Nicole Jaffrezic-Renault,et al. Conductometric biosensors based on cholinesterases for sensitive detection of pesticides , 1994 .
[14] A. Roda,et al. Chemiluminescent flow sensor for the determination of Paraoxon and Aldicarb pesticides , 1994 .
[15] Gerhard J. Mohr,et al. Optical sensors for a wide pH range based on azo dyes immobilized on a novel support , 1994 .
[16] A. Townshend,et al. Flow-injection study of inhibition and reactivation of immobilized acetylcholinesterase: determination of the pesticides paraoxon and carbamoylcholine , 1993 .
[17] Francesco Baldini,et al. Optical-fibre sensors by silylation techniques☆ , 1993 .
[18] Otto S. Wolfbeis,et al. Fiber-optic remote detection of pesticides and related inhibitors of the enzyme acetylcholine esterase☆ , 1993 .
[19] G. Schwedt,et al. Comparison of immobilization methods for the development of an acetylcholinesterase biosensor , 1993 .
[20] Jean-Louis Marty,et al. Biosensor for detection of organophosphate and carbamate insecticides , 1992 .
[21] Mauro Bacci,et al. Spectroscopic Behavior of Acid-Base Indicators after Immobilization on Glass Supports , 1991 .
[22] K R Rogers,et al. Acetylcholinesterase fiber-optic biosensor for detection of anticholinesterases. , 1991, Fundamental and applied toxicology : official journal of the Society of Toxicology.
[23] K. Hassall. The Biochemistry and Uses of Pesticides: Structure, Metabolism, Mode of Action and Uses in Crop Protection , 1990 .
[24] Rolf Schmid,et al. Biosensors: Applications in Medicine, Environmental Protection, and Process Control , 1989 .
[25] S R Goldstein,et al. Fiber optic pH probe for physiological use. , 1980, Analytical chemistry.
[26] R. Murray,et al. Spectrophotometric study of coverage and acid-base equilibrium of a chemically bonded base , 1977 .
[27] G. Harper. Reusable glass-bound pH indicators , 1975 .
[28] K. Courtney,et al. A new and rapid colorimetric determination of acetylcholinesterase activity. , 1961, Biochemical pharmacology.
[29] M. D. Luque de Castro,et al. Strategies for solid sample treatment , 1997 .
[30] C Cremisini,et al. Anticholinesterase activity measurement by a choline biosensor: application in water analysis. , 1993, Biosensors & bioelectronics.
[31] J. Polster,et al. 048 Fiber optic biosensor for pesticides based on acetylcholine esterase , 1992 .
[32] A. Townshend,et al. Determination of organophosphorus and carbamate pesticide standards by liquid chromatography with detection by inhibition of immobilized acetylcholinesterase , 1991 .
[33] P C Pandey,et al. Studies on acetylcholine sensor and its analytical application based on the inhibition of cholinesterase. , 1990, Biosensors & bioelectronics.
[34] C. Cámara,et al. Analytical performance of an optical pH sensor for acid-base titration , 1990 .
[35] A. Townshend,et al. Flow-injection determination of paraoxon by inhibition of immobilized acetylcholinesterase , 1990 .