A fuzzy-controlled versatile system for harmonics, unbalance and voltage sag compensation

In this paper, a proposed system comprising of a series active filter and passive branches tuned at some characteristic harmonics is introduced. The system is capable of compensating current and voltage harmonics, three-phase voltage unbalance, reactive power and voltage sags and swells in distribution networks supplying nonlinear loads. It combines the features of both the universal power quality conditioner and the dynamic voltage restorer. The series active filter is current-controlled to force the drawn current to be sinusoidal in phase with the mains voltage. A fuzzy logic-based controller is adopted to adjust the reference signal for the system. Thus, the source current and voltage waveforms are almost sinusoidal and in phase. Meanwhile, load voltage magnitude is fixed under a wide range of faulty and healthy operating conditions. Moreover, the compensation capacity of the proposed system is compared to the conventionally-controlled series active filter. The integrity and efficacy of the system are verified through simulation results.

[1]  M. M. Elkateb,et al.  Comparative study of parallel hybrid filters in resonance damping , 1999, PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376).

[2]  Math Bollen,et al.  Experimental investigation of voltage sag mitigation by an advanced static VAr compensator , 1998 .

[3]  G. Joos,et al.  Distribution system voltage regulation under fault conditions using static series regulators , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[4]  Mauricio Aredes,et al.  An universal active power line conditioner , 1998 .

[5]  A. Elmitwally,et al.  Universal power quality manager with a new control scheme , 2000 .

[6]  R. S. Weissbach,et al.  Dynamic voltage compensation on distribution feeders using flywheel energy storage , 1999 .

[7]  Juan W. Dixon,et al.  A series active power filter based on a sinusoidal current-controlled voltage-source inverter , 1997, IEEE Trans. Ind. Electron..

[8]  Hirofumi Akagi,et al.  The unified power quality conditioner: the integration of series- and shunt-active filters , 1998 .

[9]  Prasad N. Enjeti,et al.  A fast active power filter to correct line voltage sags , 1994, IEEE Trans. Ind. Electron..

[10]  R. Spee,et al.  Voltage sag ride-through for adjustable speed drives with active rectifiers , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.