Rectal perflubron: new application in MRI of perirectal fistulae.

PURPOSE Our goal was to determine the efficacy of MRI with rectal administration of perflubron in the evaluation of perirectal and pelvic fistulae, with an emphasis on development of an improved method for fistula visualization. METHOD Fourteen pelvic and/or perirectal fistulae were evaluated in nine patients with MRI after the rectal administration of 200 ml of perflubron. Images were reviewed by two independent readers and evaluated for the presence or absence of fistulae. Qualitative assessment was also performed, rating the examinations for the ability to visualize the fistulae. Comparison was made with the clinical examination and/or operative findings, as well as available preperflubron imaging studies (CT = 10; fluoroscopy = 1; preperflubron MRI = 4). RESULTS MRI with rectal perflubron demonstrated all 14 fistulae (100%), while preperflubron imaging demonstrated only 7 of 14 (50%) fistulae (p < or = 0.008, Wilcoxon signed rank test). In addition, MRI with perflubron resulted in significantly improved qualitative visualization of fistulae (overall very good rating versus poor rating for preperflubron imaging, p < or = 0.006, Wilcoxon signed rank test). CONCLUSION MRI with rectal perflubron is a superior modality for imaging of fistulae, compared with conventional methods, since it allows a noninvasive means of demonstrating the presence of a fistula as well as offers improved qualitative assessment of fistulous disease.

[1]  S. Hussain,et al.  Endoanal coil in MR imaging of anal fistulas. , 1996, AJR. American journal of roentgenology.

[2]  D. Jewell,et al.  Pelvic and perineal complications of Crohn's disease: assessment using magnetic resonance imaging. , 1995, Gut.

[3]  R. Reznek,et al.  Magnetic resonance imaging of fistula-in-ano , 1994, Diseases of the colon and rectum.

[4]  R. Mattrey,et al.  Perflubron as an oral contrast agent for MR imaging: results of a phase III clinical trial. , 1994, Radiology.

[5]  T. Pilgram,et al.  MR imaging of crohn disease: Use of perflubron as a gastrointestinal contrast agent , 1994, Journal of magnetic resonance imaging : JMRI.

[6]  G. Myhr,et al.  Perianal fistulas: use of MR imaging for diagnosis. , 1994, Radiology.

[7]  C. Grandin,et al.  MRI of Complicated Anal Fistulae: Comparison with Digital Examination , 1994, Journal of computer assisted tomography.

[8]  B. Coley,et al.  Value of brominated fluorocarbons for the radiographic diagnosis of small-bowel obstruction: comparison with other contrast agents in rats. , 1993, AJR. American journal of roentgenology.

[9]  D. Carney,et al.  Perfluorooctylbromide as a contrast agent for CT and sonography: preliminary clinical results. , 1993, AJR. American journal of roentgenology.

[10]  M. Schiebler,et al.  Pelvic fistulas: findings on MR images. , 1993, AJR. American journal of roentgenology.

[11]  R. Reznek,et al.  Magnetic resonance imaging of anal fistulae , 1992, The Lancet.

[12]  J. Heiken,et al.  Perfluoroctylbromide as a gastrointestinal contrast agent for MR imaging: use with and without glucagon. , 1991, Radiology.

[13]  J. Martin,et al.  Perfluorochemicals as gastrointestinal contrast agents for MR imaging: preliminary studies in rats and humans. , 1987, AJR. American journal of roentgenology.

[14]  E. Fishman,et al.  CT in the diagnosis of enterovesical fistulae. , 1985, AJR. American journal of roentgenology.

[15]  D. Long,et al.  Efficacy and toxicity studies with radiopaque perfluorocarbon. , 1972, Radiology.

[16]  R. Reznek,et al.  Magnetic resonance imaging of fistula-in-ano: technique, interpretation and accuracy. , 1994, Clinical radiology.

[17]  D. Long,et al.  Perfluoroctylbromide as a diagnostic contrast medium in gastroenterography. , 1977, Radiology.