Multiple site electromyograph amplitude estimation

Temporal whitening of individual surface electromyograph (EMG) waveforms and spatial combination of multiple recording sites have separately been demonstrated to improve the performance of EMG amplitude estimation. This investigation combined these two techniques by first whitening, then combining the data from multiple EMG recording sites to form an EMG amplitude estimate. A phenomenological mathematical model of multiple sites of the surface EMG waveform, with analytic solution for an optimal amplitude estimate, is presented. Experimental surface EMG waveforms were then sampled from multiple sites during nonfatiguing, constant-force, isometric contractions of the biceps or triceps muscles, over the range of 10-75% maximum voluntary contraction. A signal-to-noise ratio (SNR) was computed from each amplitude estimate (deviations about the mean value of the estimate were considered as noise). Results showed that SNR performance: 1) increased with the number of EMG sites, 2) was a function of the sampling frequency, 3) was predominantly invariant to various methods of determining spatial uncorrelation filters, 4) was not sensitive to the intersite correlations of the electrode configuration investigated, and 5) was best at lower levels of contraction. A moving average root mean square estimator (245-ms window) provided an average /spl plusmn/ standard deviation (A/spl plusmn/SD) SNR of 10.7/spl plusmn/3.3 for single site unwhitened recordings. Temporal whitening and four combined sites improved the A/spl plusmn/SD SNR to 24.6/spl plusmn/10.4. On one subject, eight whitened combined sites were achieved, providing an A/spl plusmn/SD SNR of 35.0/spl plusmn/13.4.<<ETX>>

[1]  J. Saunders,et al.  Relation of human electromyogram to muscular tension. , 1952, Electroencephalography and clinical neurophysiology.

[2]  E. Müller,et al.  Physiological methods of increasing human physical work capacity. , 1965, Ergonomics.

[3]  H. Kwatny,et al.  An application of signal processing techniques to the study of myoelectric signals. , 1970, IEEE transactions on bio-medical engineering.

[4]  P. Herberts The Control of upper-extremity prostheses and orthoses , 1974 .

[5]  Robert W. Mann,et al.  Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part I: Derivation of the Optimal Myoprocessor , 1980, IEEE Transactions on Biomedical Engineering.

[6]  Neville Hogan,et al.  Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography - Part II: Experimental Demonstration of Optimal Myoprocessor Performance , 1980, IEEE Transactions on Biomedical Engineering.

[7]  M I Harba,et al.  Optimizing the acquisition and processing of surface electromyographic signals. , 1981, Journal of biomedical engineering.

[8]  Gian Carlo Filligoi,et al.  Some Theoretic Results on a Digital EMG Signal Processor , 1984, IEEE Transactions on Biomedical Engineering.

[9]  T D'Alessio Some results on the optimization of a digital processor for surface EMG signals. , 1984, Electromyography and clinical neurophysiology.

[10]  W R Murray,et al.  An optimal real-time digital processor for the electric activity of muscle. , 1985, Medical instrumentation.

[11]  William H. Press,et al.  Numerical Recipes in FORTRAN - The Art of Scientific Computing, 2nd Edition , 1987 .

[12]  F. A. Seiler,et al.  Numerical Recipes in C: The Art of Scientific Computing , 1989 .

[13]  S. Thusneyapan,et al.  A practical electrode-array myoprocessor for surface electromyography , 1989, IEEE Transactions on Biomedical Engineering.

[14]  Neville Hogan,et al.  EMG Amplitude Estimation From Temporally Whitened, Spatially Uncorrelated Multiple Channel EMG , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  A. Edward Stochastic modeling of the relationship between the surface electromyogram and muscle torque , 1991 .

[16]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[17]  N. Hogan,et al.  Single site electromyograph amplitude estimation , 1994, IEEE Transactions on Biomedical Engineering.