Intra-aneurysm pressure measurements in successfully excluded abdominal aortic aneurysm after endovascular repair.

PURPOSE This study was performed to determine intra-aneurysm sac pressure of abdominal aortic aneurysm after endovascular aneurysm repair in patients considered successfully treated with aneurysm shrinkage and absence of endovascular leakage. METHODS In 10 patients with median aneurysm shrinkage of 12 mm (range, 7 to 22 mm) and median follow-up of 19 months (range, 14-43 months), a percutaneous translumbar intra-aneurysm pressure measurement was made with a 0.014-inch guide wire-mounted pressure sensor and compared with intra-aortic pressure. RESULTS Median intra-aneurysm systolic/diastolic/mean pressure was 19/18/19 (range, 17-35/13-33/17-31) compared with median intra-aortic pressure of 135/75/99 (range, 126-199/60-95/84-129). Mean intra-aneurysm pressure was 20% of mean intra-aortic pressure (range, 13%-33%). Pulsatility was negligible. CONCLUSION Successful endovascular aneurysm repair of abdominal aortic aneurysm results in considerable pressure reduction in the aneurysm sac. The ability to monitor intra-aneurysm pressure provides hemodynamic information within the sac, which can be used in conjunction with imaging to determine whether a secondary intervention is warranted.

[1]  William Wijns,et al.  Fractional Flow Reserve to Determine the Appropriateness of Angioplasty in Moderate Coronary Stenosis: A Randomized Trial , 2001, Circulation.

[2]  M. Lindh,et al.  Changing aneurysmal morphology after endovascular grafting: relation to leakage or persistent perfusion. , 1997, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[3]  J. H. van Bockel,et al.  Experimental study of the influence of endoleak size on pressure in the aneurysm sac and the consequences of thrombosis , 2000, The British journal of surgery.

[4]  L. Tenerz,et al.  The first surface micromachined pressure sensor for cardiovascular pressure measurements , 1998, Proceedings MEMS 98. IEEE. Eleventh Annual International Workshop on Micro Electro Mechanical Systems. An Investigation of Micro Structures, Sensors, Actuators, Machines and Systems (Cat. No.98CH36176.

[5]  R. Fairman,et al.  Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. , 2001, Journal of vascular surgery.

[6]  I. Loftus,et al.  Quality control during endovascular aneurysm repair: monitoring aneurysmal sac pressure and superficial femoral artery flow velocity. , 1999 .

[7]  S. Hans,et al.  Pressure measurements in closed aneurysmal sac during abdominal aortic aneurysm resection. , 2001, Journal of vascular surgery.

[8]  R. Berguer,et al.  Intra-aneurysmal pressure after incomplete endovascular exclusion. , 2001, Journal of vascular surgery.

[9]  P. Faries,et al.  Chronic intraaneurysmal pressure measurement: an experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion. , 1997, Journal of vascular surgery.

[10]  T. Resch,et al.  Aneurysm pressure following endovascular exclusion. , 1997, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.