Experimental study of impinging heat transfer along rib-roughened walls by using transient liquid crystal technique

Abstract The objective of this work is to examine the detailed heat transfer coefficient distributions over a ribbed surface under impingement of in-line and staggered jet arrays by using a liquid crystal thermograph technique. In-line and staggered jet arrays with different exit flow orientations were considered. Three jet-to-target spacing Z of 3, 6 and 9 with in-line and staggered jet arrays were considered at jet Reynolds numbers of Re = 1500, 3000 and 4500 with three different exit flow orientations. In addition, the effects of rib configuration on the heat transfer distributions were discussed in detail. Results show that the local heat transfer rates over the ribbed surface are characterized by obvious periodic-type variation of Nusselt number distributions. The downstream peaks are diminished for increasing cross flow effect. Compared to the results without ribs, the heat transfer over the ribbed surface may be enhanced or retarded. Whereas, among the test angled-rib arrangements, the best heat transfer performance is obtained with a surface with 45° angled ribs.

[1]  Je-Chin Han,et al.  Impingement heat transfer on dimpled surfaces using a transient liquid crystal technique , 2000 .

[2]  Je-Chin Han,et al.  Detailed heat transfer distributions under an array of orthogonal impinging jets , 1998 .

[3]  Raymond Viskanta,et al.  Effect of jet-jet spacing on convective heat transfer to confined, impinging arrays of axisymmetric air jets , 1994 .

[4]  Je-Chin Han,et al.  Heat transfer enhancement in channels with turbulence promoters , 1984 .

[5]  Chyi-Yeou Soong,et al.  EXPERIMENTAL STUDY OF IMPINGING HEAT TRANSFER OF INLINE AND STAGGERED JET ARRAYS BY TRANSIENT LIQUID CRYSTAL TECHNIQUE , 2003 .

[6]  Je-Chin Han,et al.  Heat Transfer Characteristics of Turbulent Flow in a Square Channel With Angled Discrete Ribs , 1991 .

[7]  C. Tien Annual Review of Heat Transfer , 1993 .

[8]  B. W. Webb,et al.  The Effect of Drainage Configuration on Heat Transfer Under an Impinging Liquid Jet Array , 1999 .

[9]  Je-Chin Han,et al.  Heat Transfer and Friction in Channels With Two Opposite Rib-Roughened Walls , 1984 .

[10]  T. V. Jones,et al.  Detailed Measurements of Local Heat Transfer Coefficient and Adiabatic Wall Temperature Beneath an Array of Impinging Jets , 1993 .

[11]  C. Soong,et al.  Measurement of detailed heat transfer on a surface under arrays of impinging elliptic jets by a transient liquid crystal technique , 2004 .

[12]  John H. Lienhard,et al.  LIQUID JET IMPINGEMENT , 1995 .

[13]  Chie Gau,et al.  Surface Curvature Effect on Slot-Air-Jet Impingement Cooling Flow and Heat Transfer Process , 1991 .

[14]  Je-Chin Han,et al.  Local heat/mass transfer distributions around sharp 180 deg turns in two-pass smooth and rib-roughened channels , 1988 .

[15]  C. Gau,et al.  Impingement cooling flow structure and heat transfer along rib-roughened walls , 1992 .

[16]  L. W. Florschuetz,et al.  Streamwise Flow and Heat Transfer Distributions for Jet Array Impingement with Crossflow , 1981 .

[17]  Je-Chin Han,et al.  High performance heat transfer ducts with parallel broken and V-shaped broken ribs , 1992 .

[18]  Wei-Mon Yan,et al.  Experimental Study of Surface-Mounted Obstacle Effects on Heat Transfer Enhancement by Using Transient Liquid Crystal Thermograph , 2002 .