Detrended fluctuation analysis for major depressive disorder

Clinical utility of Electroencephalography (EEG) based diagnostic studies is less clear for major depressive disorder (MDD). In this paper, a novel machine learning (ML) scheme was presented to discriminate the MDD patients and healthy controls. The proposed method inherently involved feature extraction, selection, classification and validation. The EEG data acquisition involved eyes closed (EC) and eyes open (EO) conditions. At feature extraction stage, the de-trended fluctuation analysis (DFA) was performed, based on the EEG data, to achieve scaling exponents. The DFA was performed to analyzes the presence or absence of long-range temporal correlations (LRTC) in the recorded EEG data. The scaling exponents were used as input features to our proposed system. At feature selection stage, 3 different techniques were used for comparison purposes. Logistic regression (LR) classifier was employed. The method was validated by a 10-fold cross-validation. As results, we have observed that the effect of 3 different reference montages on the computed features. The proposed method employed 3 different types of feature selection techniques for comparison purposes as well. The results show that the DFA analysis performed better in LE data compared with the IR and AR data. In addition, during Wilcoxon ranking, the AR performed better than LE and IR. Based on the results, it was concluded that the DFA provided useful information to discriminate the MDD patients and with further validation can be employed in clinics for diagnosis of MDD.

[1]  C. Bowden,et al.  A different depression: clinical distinctions between bipolar and unipolar depression. , 2005, Journal of affective disorders.

[2]  S. Leistedt,et al.  Characterization of the sleep EEG in acutely depressed men using detrended fluctuation analysis , 2007, Clinical Neurophysiology.

[3]  H. Begleiter,et al.  Alcoholism and Human Electrophysiology , 2003, Alcohol research & health : the journal of the National Institute on Alcohol Abuse and Alcoholism.

[4]  Roberto Hornero,et al.  A Study on the Possible Usefulness of Detrended Fluctuation Analysis of the Electroencephalogram Background Activity in Alzheimer's Disease , 2008, IEEE Transactions on Biomedical Engineering.

[5]  Thomas Penzel,et al.  Comparison of detrended fluctuation analysis and spectral analysis for heart rate variability in sleep and sleep apnea , 2003, IEEE Transactions on Biomedical Engineering.

[6]  Dae-Jin Kim,et al.  Detrended fluctuation analysis of EEG in sleep apnea using MIT/BIH polysomnography data , 2002, Comput. Biol. Medicine.

[7]  Jing Zhou,et al.  Automatic detection of sleep apnea based on EEG detrended fluctuation analysis and support vector machine , 2015, Journal of Clinical Monitoring and Computing.

[8]  H. Stanley,et al.  Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. , 1995, Chaos.

[9]  Pere Caminal,et al.  Detrended Fluctuation Analysis of EEG as a Measure of Depth of Anesthesia , 2007, IEEE Transactions on Biomedical Engineering.

[10]  D. Segal Diagnostic and Statistical Manual of Mental Disorders (DSM-IV-TR) , 2010 .

[11]  Xavier Bornas,et al.  Long range temporal correlations in EEG oscillations of subclinically depressed individuals: their association with brooding and suppression , 2014, Cognitive Neurodynamics.

[12]  Jang-Han Lee,et al.  Detrended fluctuation analysis of resting EEG in depressed outpatients and healthy controls , 2007, Clinical Neurophysiology.