Local heat transfer measurements of an orthogonally rotating square duct with angled rib turbulators

Abstract The effect of angled rib turbulators on the heat transfer of an orthogonally rotating square duct were experimentally investigated. The Reynolds and rotation numbers were varied in 10,000–20,000 and 0–0.08, respectively. The leading and trailing walls were rib-roughened with angles of 90° and 60°. The results showed that the rotation induced a peripheral variation of the heat transfer and the higher heat transfer was seen using the 60° angled rib; judging from the local heat transfer variation, the skewed secondary flow induced by the angled rib seemed to result in additional heat transfer enhancement.

[1]  M. Taslim,et al.  Darryl E. Metzger Memorial Session Paper: Experimental Heat Transfer and Friction in Channels Roughened With Angled, V-Shaped, and Discrete Ribs on Two Opposite Walls , 1996 .

[2]  R. Zerkle,et al.  Prediction of Turbulent Flow and Heat Transfer in a Ribbed Rectangular Duct With and Without Rotation , 1993 .

[3]  Mohammad E. Taslim,et al.  Rib Heat Transfer Coefficient Measurements in a Rib-Roughened Square Passage , 1996 .

[4]  M. Taslim,et al.  EXPERIMENTAL HEAT TRANSFER AND FRICTION IN CHANNELS ROUGHENED WITH ANGLED, V-SHAPED AND DISCRETE RIBS ON TWO OPPOSITE WALLS , 1994 .

[5]  Je-Chin Han,et al.  Detailed heat transfer distributions in two-pass square channels with rib turbulators , 1997 .

[6]  Hector Iacovides,et al.  Developing Buoyancy-Modified Turbulent Flow in Ducts Rotating in Orthogonal Mode , 1995 .

[7]  Sadanari Mochizuki,et al.  Effects of Rib Arrangements on Pressure Drop and Heat Transfer in a Rib-Roughened Channel With a Sharp 180 deg Turn , 1997 .

[8]  B. Lakshminarayana Fluid dynamics and heat transfer of turbomachinery , 1995 .

[9]  J. C. Han,et al.  Effect of Rib-Angle Orientation on Local Mass Transfer Distribution in a Three-Pass Rib-Roughened Channel , 1991 .

[10]  Bassam A. Younis,et al.  A second-moment closure study of rotating channel flow , 1987, Journal of Fluid Mechanics.

[11]  M. Taslim,et al.  Effects of turbulator profile and spacing on heat transfer and friction in a channel , 1994 .

[12]  S. Mochizuki,et al.  Heat Transfer in Serpentine Flow Passages with Rotation , 1992 .

[13]  A. Murata,et al.  DETAILED MEASUREMENT OF LOCAL HEAT TRANSFER IN A SQUARE-CROSS-SECTION DUCT WITH A SHARP 180-DEG TURN , 1994 .

[14]  Sadanari Mochizuki,et al.  Detailed Measurement of Convective Heat Transfer in Rotating Two-Pass Rib-Roughened Coolant Channels , 1996 .

[15]  J. Whitelaw,et al.  Convective heat and mass transfer , 1966 .