Improvements in high resolution ultrasound for postoperative investigation of capillary microperfusion after free tissue transfer.

INTRODUCTION High resolution ultrasound (US) techniques as implemented in the latest generation of US machines provide imminently better resolution compared to previous high resolution models. This improvement is based on advanced transducer technologies as well as updated post-processing procedures. Furthermore, matrix linear transducers providing frequencies from 6 to 15 MHz are now available. The aim of the study was the evaluation of these new techniques for the immediate postoperative investigation of microcirculation after free tissue transfer by supplemental use of Contrast-Enhanced Ultrasound Imaging (CEUS). PATIENTS AND METHODS To this end, we investigated 12 patients who underwent free tissue transfer in order to cover tissue defects in various body regions. We utilized the new GE Logiq E9 equipped with a linear 6-9 MHz and a matrix 6-15 MHz probe as well as the GE Logiq 9 with the previous version of the linear 6-9 MHz probe. Both machines provide the modalities of SRI, Cross Beam and THI. The perfusion curves were quantitatively analyzed using digital cine sequences (Qontrast, Bracco, Italy). Furthermore, two independent investigators evaluated the digitally recorded images with respect to the resolution of details based on a scale ranging from 0 to 5, and after application of 2.4 ml SonoVue (Bracco, Italy), evaluated the image quality regarding the representation of tissue perfusion. RESULTS None of the free flaps showed clinical or laboratory signs of flap failure during the hospital stay. Several flaps showed typical perfusion patterns relating to the flap type. The combination of SRI, Cross Beam and THI allows, in most cases, a more exact differentiation of tissue graft outlines and tissue composition, in particular the tissue texture, compared to the use of B-scan only. In addition, the high resolution matrix technology combined with the broader spectrum of 6-15 MHz considerably improves the representation of image details compared to multifrequency probes with 6-9 MHz. The use of updated post-processing procedures as well as new transducer technologies in CEUS also results in improved resolution and thus achieves a higher score compared to previous models. CONCLUSION At present, these new US technologies combined with the updated 6-9 MHz probe provide the optimal assessment of perfusion in cutaneous, subcutaneous and deeper tissue layers. The additional use of new multifrequency 6-15 MHz matrix probes improves the resolution in the B-mode to an even higher degree.

[1]  M. Gallegos,et al.  Contrast enhanced harmonic ultrasound for differentiating breast tumors - first results. , 2005, Clinical hemorheology and microcirculation.

[2]  E. Jung,et al.  Vascularization and perfusion of hepatocellular carcinoma: assessment with contrast-enhanced ultrasound using perflutren protein-type A microspheres. , 2005, Clinical hemorheology and microcirculation.

[3]  E. Jung,et al.  Value of high resolution ultrasound and contrast enhanced US pulse inversion imaging for the evaluation of the vascular integrity of free-flap grafts. , 2007, Clinical hemorheology and microcirculation.

[4]  Alexander Schramm,et al.  Color duplex sonography for the monitoring of vascularized free bone flaps , 2003, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[5]  C J Green,et al.  The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery. , 1998, British journal of plastic surgery.

[6]  D A Hidalgo,et al.  Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases. , 1999, Plastic and reconstructive surgery.

[7]  A. Halim,et al.  Method optimization on the use of postocclusive hyperemia model to assess microvascular function. , 2008, Clinical hemorheology and microcirculation.

[8]  P Lamby,et al.  Contrast harmonic ultrasound and indocyanine-green fluorescence video angiography for evaluation of dermal and subdermal microcirculation in free parascapular flaps. , 2008, Clinical hemorheology and microcirculation.

[9]  D. Karakitsos,et al.  Blood Perfusion of the Free Anterolateral Thigh Perforator Flap: Its Beneficial Effect in the Reconstruction of Infected Wounds in the Lower Extremity , 2006, World Journal of Surgery.

[10]  F. Siemers,et al.  Flap Perfusion after Free Musculocutaneous Tissue Transfer: The Impact of Postoperative Complications , 2000, Plastic and reconstructive surgery.

[11]  B. Stack,et al.  Color Doppler Ultrasonography is a Reliable Predictor of Free Tissue Transfer Outcomes in Head and Neck Reconstruction , 2006, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[12]  J. Legagneux,et al.  [Vascular microsurgery and progress of free flap surgery]. , 2001, Annales de Chirurgie.

[13]  Sukru Mehmet Erturk,et al.  Benign and malignant breast lesions: efficacy of real time contrast-enhanced ultrasound vs. magnetic resonance imaging. , 2007, Ultraschall in der Medizin.

[14]  M. Kıyak,et al.  Review of monitoring free muscle flap transfers in reconstructive surgery: role of 99mTc sestamibi scintigraphy , 2006, Nuclear medicine communications.

[15]  P Lamby,et al.  Evaluation of the vascular integrity of free flaps based on microcirculation imaging techniques. , 2008, Clinical hemorheology and microcirculation.

[16]  H. Weskott Emerging roles for contrast-enhanced ultrasound. , 2008, Clinical hemorheology and microcirculation.

[17]  E. Jung,et al.  Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison). , 2006, Clinical hemorheology and microcirculation.