Flow visualization in the outflow cannula of an axial blood pump.

The properties of blood flow in the outflow cannula of an axial blood pump play a critical role in potential thrombus formation and vascular injury. In this study, an in vitro flow visualization technique using particle image velocimetry (PIV) was applied to investigate the flow characteristics in the outflow cannula of a FW-2 model axial pump. The two-dimensional (2-D) flow field in the axial central section and the three-dimensional (3-D) flow field in the whole outflow cannula were examined with the PIV system. Tests were carried out with a blood-mimic working fluid in the axial pump at a rotational speed of 8500 ± 20 rpm with a flow rate of 5 L/min. The velocity distribution in the outflow cannula was analyzed to evaluate the flow characteristics. There was no backflow or stagnant flow in the tested area, while the flow velocity rapidly increased outside the boundary layer. A spiral flow was observed near the boundary layer, but this was worn off within the tested area. Based on the results, hemolysis and thrombus formation in the cannula, and injury to aortic endothelium are unlikely to occur due to spiral flow.

[1]  Keefe B Manning,et al.  Flow through an outlet cannula of a rotary ventricular assist device. , 2002, Artificial organs.

[2]  Xinwei Song,et al.  Inlet and outlet devices for rotary blood pumps. , 2004, Artificial organs.

[3]  Steven W Day,et al.  PIV measurements of flow in a centrifugal blood pump: time-varying flow. , 2005, Journal of biomechanical engineering.

[4]  Wei Jiang,et al.  Computational Design and Experimental Performance Testing of an Axial-Flow Pediatric Ventricular Assist Device , 2005, ASAIO journal.

[5]  Wolfgang Schröder,et al.  Computational fluid dynamics and digital particle image velocimetry study of the flow through an optimized micro-axial blood pump. , 2006, Artificial organs.

[6]  H Zhang,et al.  Design and performance testing of an axial-flow ventricular assist device developed at the Fu Wai Hospital in Beijing , 2008, The International journal of artificial organs.

[7]  Evaluation of the impeller shroud performance of an axial flow ventricular assist device using computational fluid dynamics. , 2010, Artificial organs.

[8]  Ulrich Steinseifer,et al.  Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch. , 2010, Artificial organs.

[9]  Xiao-Chen Yang,et al.  Computational fluid dynamics-based hydraulic and hemolytic analyses of a novel left ventricular assist blood pump. , 2011, Artificial organs.

[10]  E. Tatsumi,et al.  Flow visualization for different port angles of a pulsatile ventricular assist device , 2012, Journal of Artificial Organs.

[11]  Computational fluid dynamic analysis to prevent aortic root and valve clots during left ventricular assist device support. , 2012, The journal of extra-corporeal technology.

[12]  X. Gui,et al.  Particle image velocimetry experimental and computational investigation of a blood pump , 2012 .

[13]  Nishant R. Shah,et al.  Transthoracic echocardiography of the HeartWare left ventricular assist device. , 2011, Journal of cardiac failure.

[14]  M. Loebe,et al.  Influence of LVAD Cannula Outflow Tract Location on Hemodynamics in the Ascending Aorta: A Patient-Specific Computational Fluid Dynamics Approach , 2012, ASAIO journal.

[15]  Marissa Miller,et al.  Long-term mechanical circulatory support (destination therapy): on track to compete with heart transplantation? , 2012, The Journal of thoracic and cardiovascular surgery.

[16]  A. Dispenzieri,et al.  Left ventricular device implantation for advanced cardiac amyloidosis. , 2013, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[17]  K. Muthiah,et al.  Centrifugal Continuous-Flow Left Ventricular Assist Device in Patients With Hypertrophic Cardiomyopathy: A Case Series , 2013, ASAIO journal.

[18]  P. McCarthy,et al.  Complex HeartMate II Infection Treated with Pump Exchange to HeartWare HVAD , 2013, ASAIO journal.