Electrode-Skin contact impedance: In vivo measurements on an ovine model

The problem of electrical impedance between the skin and the electrode is an on-going challenge in bio-electronics. This is particularly true in the case of Electrical Impedance Tomography (EIT), which uses a large number of skin-contact electrodes and is very sensitive to noise. In the present article, contact impedance is measured and compared for a range of electrodes placed on the thorax of an ovine model. The study has been approved by the Westmead Hospital Animal Ethics Committee. The electrode models that were employed in the research are Ag/AgCl electrodes (E1), commonly used for ECG and EIT measurements in both humans and animal models, stainless steel crocodile clips (E2), typically used on animal models, and novel multi-point dry electrodes in two modifications: bronze plated (E3) and nickel plated (E4). Further, since the contact impedance is mostly attributed to the acellular outer layer of the skin, in our experiment, we attempted to study the effect of this layer by comparing the results when the skin is intact and when electrodes are introduced underneath the skin through small cuts. This boundary effect was assessed by comparison of measurements obtained during E2 skin surface contact, and sub-cutaneous contact (E5). Twelve gauge intradermal needles were also tested as an electrode (E6). The full impedance spectrum, from 500 Hz to 300 kHz, was recorded, analysed and compared. As expected, the contact impedance in the more invasive cases, i.e the electrodes under the skin, is significantly lower than in the non-invasive cases. At the frequency of 50 kHz which is commonly used in lung EIT acquisition, electrodes E3, E4 and E6 demonstrated contact impedance of less than 200 Ω, compared to more than 400 Ω measured for electrodes E1, E2 and E5. In conclusion, the novel multipoint electrodes proved to be best suited for EIT purposes, because they are non-invasive and have lower contact impedance than Ag/AgCl and crocodile clips, in both invasive and non-invasive cases. This further prompted us to design a flexible electrode belt using the novel multi-point electrodes for lung EIT on animal models.

[1]  Yongqin Li,et al.  Identifying potentially shockable rhythms without interrupting cardiopulmonary resuscitation* , 2008, Critical care medicine.

[2]  P S Hamilton,et al.  Effect of adaptive motion-artifact reduction on QRS detection. , 2000, Biomedical instrumentation & technology.

[3]  Stephen E. Rose,et al.  Rapid EEG changes indicate reperfusion after tissue plasminogen activator injection in acute ischaemic stroke , 2006, Clinical Neurophysiology.

[4]  H. Jongsma,et al.  Electrical properties of tissues involved in the conduction of foetal ECG , 1989, Medical and Biological Engineering and Computing.

[5]  L. Kirkup,et al.  A direct comparison of wet, dry and insulating bioelectric recording electrodes. , 2000, Physiological measurement.

[6]  Alistair McEwan,et al.  Electrode contact impedance sensitivity to variations in geometry. , 2012, Physiological measurement.

[7]  R Bayford,et al.  Design and calibration of a compact multi-frequency EIT system for acute stroke imaging. , 2006, Physiological measurement.

[8]  D S Holder,et al.  A review of errors in multi-frequency EIT instrumentation , 2007, Physiological measurement.

[9]  T. Yamamoto,et al.  Characteristics of skin admittance for dry electrodes and the measurement of skin moisturisation , 2006, Medical and Biological Engineering and Computing.

[10]  S E Moulton,et al.  Electrode-Cellular Interface , 2009, Science.

[11]  Heinz Jäckel,et al.  Continuous Monitoring of Electrode--Skin Impedance Mismatch During Bioelectric Recordings , 2008, IEEE Transactions on Biomedical Engineering.