Mobile-bearing Knees Reduce Rotational Asymmetric Wear
暂无分享,去创建一个
Jiann-Jong Liau | J. Liau | Chun‐Hsiung Huang | F. Ho | Chun-Hsiung Huang | Hon-Ming Ma | Fang-Yuan Ho | Hon-Ming Ma | Chuan-Ren Yeh | C.-R. Yeh
[1] T. Wright,et al. Wear of polyethylene in total joint replacements. Observations from retrieved PCA knee implants. , 1992, Clinical orthopaedics and related research.
[2] S. Matsuda,et al. Knee Kinematics of Posterior Cruciate Ligament Sacrificed Total Knee Arthroplasty , 1997, Clinical orthopaedics and related research.
[3] J O Galante,et al. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. , 1994, Clinical orthopaedics and related research.
[4] J. Liau,et al. Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties—a comparison between mobile bearing and fixed bearing knees , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[5] L. Whiteside. Effect of Porous‐Coating Configuration on Tibial Osteolysis After Total Knee Arthroplasty , 1995, Clinical orthopaedics and related research.
[6] Chun‐Hsiung Huang,et al. Long-Term Results of Low Contact Stress Mobile-Bearing Total Knee Replacements , 2003, Clinical orthopaedics and related research.
[7] R. Malhotra,et al. A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. , 2005, The Journal of bone and joint surgery. American volume.
[8] A H Burstein,et al. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. , 1983, Journal of biomedical materials research.
[9] Buechel Ff,et al. New Jersey low contact stress knee replacement system. Ten-year evaluation of meniscal bearings. , 1989 .
[10] G. Engh,et al. Osteolysis after total knee arthroplasty without cement. , 1992, The Journal of bone and joint surgery. American volume.
[11] S. Banks,et al. A kinematic comparison of fixed- and mobile-bearing knee replacements. , 2006, The Journal of bone and joint surgery. British volume.
[12] Y. Kim,et al. Osteolysis around cementless porous-coated anatomic knee prostheses. , 1995, The Journal of bone and joint surgery. British volume.
[13] T. Bauer,et al. Relationship between wear debris particles and polyethylene surface damage in primary total knee arthroplasty. , 1999, The Journal of arthroplasty.
[14] M. Porter,et al. A study of the effect of tibial tray rotation on a specific mobile bearing total knee arthroplasty. , 2005, The Journal of arthroplasty.
[15] Mohamed R Mahfouz,et al. Mobile-Bearing Total Knee Arthroplasty: Do the Polyethylene Bearings Rotate? , 2005, Clinical orthopaedics and related research.
[16] H. Cotta. [On the physiology of joints]. , 1966, Langenbecks Archiv fur Chirurgie.
[17] J. O'Connor,et al. Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis. , 1986, Clinical orthopaedics and related research.
[18] S. Gallannaugh,et al. The Roper-Tuke total elbow arthroplasty. 4- to 10-year results of an unconstrained prosthesis. , 2000, The Journal of bone and joint surgery. British volume.
[19] R. E. Jensen,et al. Analysis of the Failure of 122 Polyethylene Inserts From Uncemented Tibial Knee Components , 1991, Clinical orthopaedics and related research.
[20] J. Liau,et al. Osteolysis in Failed Total Knee Arthroplasty: A Comparison of Mobile-Bearing and Fixed-Bearing Knees , 2002, The Journal of bone and joint surgery. American volume.
[21] J. Callaghan,et al. Cemented rotating-platform total knee replacement. a concise follow-up, at a minimum of fifteen years, of a previous report. , 2005, The Journal of bone and joint surgery. American volume.
[22] L. Whiteside,et al. Effect of polyethylene quality on wear in total knee arthroplasty. , 1995, Clinical orthopaedics and related research.
[23] Jiann-Jong Liau,et al. The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses--a biomechanical study. , 2003, Clinical biomechanics.
[24] L Ryd,et al. Wear in retrieved condylar knee arthroplasties. A comparison of wear in different designs of 280 retrieved condylar knee prostheses. , 1997, The Journal of arthroplasty.
[25] L. Lidgren,et al. Polyethylene wear in knee arthroplasty. A review. , 1992, Acta orthopaedica Scandinavica.
[26] D. Bartel,et al. The problem of surface damage in polyethylene total knee components. , 1986, Clinical orthopaedics and related research.
[27] J. Liau,et al. Late Dislocation of Rotating Platform in New Jersey Low-Contact Stress Knee Prosthesis , 2002, Clinical orthopaedics and related research.
[28] L. Lidgren,et al. Polyethylene wear in knee arthroplasty , 1992 .
[29] J. Limbeek,et al. Mobile bearing vs fixed bearing prostheses for total knee arthroplasty for post-operative functional status in patients with osteoarthritis and rheumatoid arthritis. , 2001, The Cochrane database of systematic reviews.
[30] J. Fisher,et al. Quantification of third body damage to the tibial counterface in mobile bearing knees , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[31] S. Goodman,et al. Effects of polyethylene particles on tissue surrounding knee arthroplasties in rabbits. , 1998, Journal of biomedical materials research.
[32] R C Johnston,et al. Cemented Rotating-Platform Total Knee Replacement: A Nine to Twelve-Year Follow-up Study* , 2000, The Journal of bone and joint surgery. American volume.
[33] J. Galante,et al. Bone resorption activity of particulate‐stimulated macrophages , 1993, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.