MLEM algorithm adaptation for improved SPECT scintimammography

Standard MLEM and OSEM algorithms used in SPECT Tc-99m sestamibi scintimammography produce hot-spot artifacts (HSA) at the image support peripheries. We investigated a suitable adaptation of MLEM and OSEM algorithms needed to reduce HSA. Patients with suspicious breast lesions were administered 10 mCi of Tc-99m sestamibi and SPECT scans were acquired for patients in prone position with uncompressed breasts. In addition, to simulate breast lesions, some patients were imaged with a number of breast skin markers each containing 1 μCi of Tc-99m. In order to reduce HSA in reconstruction, we removed from the backprojection step the rays that traverse the periphery of the support region on the way to a detector bin, when their path length through this region was shorter than some critical length. Such very short paths result in a very low projection counts contributed to the detector bin, and consequently to overestimation of the activity in the peripheral voxels in the backprojection step -- thus creating HSA. We analyzed the breast-lesion contrast and suppression of HSA in the images reconstructed using standard and modified MLEM and OSEM algorithms vs. critical path length (CPL). For CPL ≥ 0.01 pixel size, we observed improved breast-lesion contrast and lower noise in the reconstructed images, and a very significant reduction of HSA in the maximum intensity projection (MIP) images.

[1]  James E. Bowsher,et al.  EM-IntraSPECT algorithm with ordered subsets (OSEMIS) for nonuniform attenuation correction in cardiac imaging , 2002, SPIE Medical Imaging.

[2]  James E. Bowsher,et al.  An EM algorithm for estimating SPECT emission and transmission parameters from emission data only , 2001, IEEE Transactions on Medical Imaging.

[3]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[4]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[5]  I. Mena,et al.  Technetium-99m-sestamibi scintimammography of breast lesions: clinical and pathological follow-up. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  D S Lalush,et al.  Performance of ordered-subset reconstruction algorithms under conditions of extreme attenuation and truncation in myocardial SPECT. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.