Understanding the Influences of EEG Reference: A Large-Scale Brain Network Perspective

The influence of reference is a critical issue for the electroencephalography (EEG) and event-related potentials (ERPs) studies. However, previous investigations concentrated less on the location of source at a systematic neuroscience level. Our goal was to examine the EEG signal associated with the locations from a common network parcellation of the human brain function, offering a system perspective of the influence of EEG reference. In our simulation, vertices uniformly distributed in eight large-scale brain networks were adopted to generate the scalp EEG. The brain networks contain the visual, somatomotor, dorsal attention, ventral attention, limbic, frontoparietal, default networks, and the deep brain structure. The distributions of the most sensitive and neutral electrodes were calculated for each network based on the lead-field matrix. While the most sensitive electrode had a network-specific symmetric pattern, the electrodes in scalp surface had approximately equal chance to be the most neutral electrode. Simulated data were referenced at the FCz, the Oz, the mean mastoids (MM), the average (AVE), and the infinity reference obtained by the reference electrode standardization technique (REST). Intriguingly, the relative error followed the pattern REST<AVE<MM<(FCz, Oz), regardless of the number of electrodes and signal-to-noise ratios. Our findings suggested that REST was a potentially preferable reference for all large-scale networks and AVE virtually performed as REST under several conditions. As EEG and ERPs experiments within the same behavioral domain always have activations in some specific brain networks, the comparisons revealed here may provide a valuable recommendation for reference selection in clinical and basic researches.

[1]  Dezhong Yao,et al.  A study on the reference electrode standardization technique for a realistic head model , 2004, Comput. Methods Programs Biomed..

[2]  S. Hillyard,et al.  Event-related brain potentials in the study of visual selective attention. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[3]  M. Coles Modern mind-brain reading: psychophysiology, physiology, and cognition. , 1989, Psychophysiology.

[4]  D. A. Driscoll,et al.  EEG electrode sensitivity--an application of reciprocity. , 1969, IEEE transactions on bio-medical engineering.

[5]  Marisa O. Hollinshead,et al.  The organization of the human cerebral cortex estimated by intrinsic functional connectivity. , 2011, Journal of neurophysiology.

[6]  Dezhong Yao,et al.  Why do we need to use a zero reference? Reference influences on the ERPs of audiovisual effects. , 2013, Psychophysiology.

[7]  J. Ford,et al.  The relationship between P300 amplitude and regional gray matter volumes depends upon the attentional system engaged. , 1994, Electroencephalography and clinical neurophysiology.

[8]  R. Poldrack,et al.  From Brain Maps to Cognitive Ontologies: Informatics and the Search for Mental Structure. , 2016, Annual review of psychology.

[9]  P. Nunez,et al.  A theoretical basis for standing and traveling brain waves measured with human EEG with implications for an integrated consciousness , 2006, Clinical Neurophysiology.

[10]  O Bertrand,et al.  A theoretical justification of the average reference in topographic evoked potential studies. , 1985, Electroencephalography and clinical neurophysiology.

[11]  Dante Mantini,et al.  Neuronal oscillations and functional interactions between resting state networks , 2014, Human brain mapping.

[12]  Tzyy-Ping Jung,et al.  Real-time neuroimaging and cognitive monitoring using wearable dry EEG , 2015, IEEE Transactions on Biomedical Engineering.

[13]  Peng Xu,et al.  A comparative study of different references for EEG default mode network: The use of the infinity reference , 2010, Clinical Neurophysiology.

[14]  Ping Yang,et al.  An Empirical Bayesian Framework for Brain–Computer Interfaces , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[15]  Filippo Zappasodi,et al.  Impact of the reference choice on scalp EEG connectivity estimation , 2016, Journal of neural engineering.

[16]  Robert Oostenveld,et al.  The five percent electrode system for high-resolution EEG and ERP measurements , 2001, Clinical Neurophysiology.

[17]  Paul L. Nunez,et al.  REST: A good idea but not the gold standard , 2010, Clinical Neurophysiology.

[18]  Paul L. Nunez,et al.  A Study of Origins of the Time Dependencies of Scalp EEG: I - Theoretical Basis , 1981, IEEE Transactions on Biomedical Engineering.

[19]  Don M. Tucker,et al.  A novel hydrogel electrolyte extender for rapid application of EEG sensors and extended recordings , 2012, Journal of Neuroscience Methods.

[20]  Dante Mantini,et al.  Estimating a neutral reference for electroencephalographic recordings: the importance of using a high-density montage and a realistic head model , 2015, Journal of neural engineering.

[21]  C. Herrmann Human EEG responses to 1–100 Hz flicker: resonance phenomena in visual cortex and their potential correlation to cognitive phenomena , 2001, Experimental Brain Research.

[22]  Richard N A Henson,et al.  The Scale of Functional Specialization within Human Prefrontal Cortex , 2010, The Journal of Neuroscience.

[23]  J. Thayer,et al.  The quest for the EEG reference revisited: a glance from brain asymmetry research. , 2001, Psychophysiology.

[24]  Dezhong Yao,et al.  Is the Surface Potential Integral of a Dipole in a Volume Conductor Always Zero? A Cloud Over the Average Reference of EEG and ERP , 2017, Brain Topography.

[25]  D. Yao,et al.  A method to standardize a reference of scalp EEG recordings to a point at infinity , 2001, Physiological measurement.

[26]  Qian Wang,et al.  Revealing the Dysfunction of Schematic Facial-Expression Processing in Schizophrenia: A Comparative Study of Different References , 2017, Front. Neurosci..

[27]  J. D. Munck The potential distribution in a layered anisotropic spheroidal volume conductor , 1988 .

[28]  Stephen M Smith,et al.  Correspondence of the brain's functional architecture during activation and rest , 2009, Proceedings of the National Academy of Sciences.

[29]  Guido Nolte,et al.  The use of standardized infinity reference in EEG coherency studies , 2007, NeuroImage.

[30]  Christopher L. Asplund,et al.  Functional Specialization and Flexibility in Human Association Cortex. , 2016, Cerebral cortex.

[31]  Dezhong Yao,et al.  fMRI functional networks for EEG source imaging , 2011, Human brain mapping.

[32]  N. Tzourio-Mazoyer,et al.  Automated Anatomical Labeling of Activations in SPM Using a Macroscopic Anatomical Parcellation of the MNI MRI Single-Subject Brain , 2002, NeuroImage.

[33]  Jürgen Kayser,et al.  In search of the Rosetta Stone for scalp EEG: Converging on reference-free techniques , 2010, Clinical Neurophysiology.

[34]  Robert Oostenveld,et al.  A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference , 2005, Physiological measurement.