Large Area Full-Field Optical Coherence Tomography and its Applications

Optical Coherence Tomography (OCT) can perform high resolution, cross-sectional tomographic imaging of the internal structure of materials and biological samples. Most of the OCT systems use fibre probe based technology, in which a 3-axis scanning mechanism is needed. As the fibre output aperture is of the order of a micron, the working area of OCT system is normally about hundreds of squared microns. Working directly on a 2D region, Full-Field OCT (FF-OCT) system has parallel processing ability. Because the size of the image does not pose a serious challenge, FF-OCT can be easily used to image a large working area. This paper discusses system design and implementation for a large area FFOCT. Different applications, 3D intensity imaging, multiple-layer information extraction and fake-fingerprint detection, are described. To further reduce the cost of system and increase and the resolution of depth, FF-OCT system using white light is also introduced.

[1]  P. Carré Installation et utilisation du comparateur photoélectrique et interférentiel du Bureau International des Poids et Mesures , 1966 .

[2]  B. Bouma,et al.  Handbook of Optical Coherence Tomography , 2001 .

[3]  H Saint-Jalmes,et al.  Full-field optical coherence microscopy. , 1998, Optics letters.

[4]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[5]  A. Dubois,et al.  Phase-map measurements by interferometry with sinusoidal phase modulation and four integrating buckets. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  Bin Liu,et al.  Theoretical and practical considerations on detection performance of time domain, Fourier domain, and swept source optical coherence tomography. , 2007, Journal of biomedical optics.

[7]  J. Fujimoto,et al.  Optical coherence tomography using a frequency-tunable optical source. , 1997, Optics letters.

[8]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[9]  T. Eiju,et al.  Digital phase-shifting interferometry: a simple error-compensating phase calculation algorithm. , 1987, Applied optics.

[10]  M. Brezinski Optical Coherence Tomography: Principles and Applications , 2006 .

[11]  G. Ha Usler,et al.  "Coherence radar" and "spectral radar"-new tools for dermatological diagnosis. , 1998, Journal of biomedical optics.

[12]  A. Boccara,et al.  High-resolution full-field optical coherence tomography with a Linnik microscope. , 2002, Applied optics.

[13]  Satoshi Hoshino,et al.  Impact of artificial "gummy" fingers on fingerprint systems , 2002, IS&T/SPIE Electronic Imaging.

[14]  Shoude Chang,et al.  An efficient algorithm used for full-field optical coherence tomography , 2007 .

[15]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[16]  Harald Sattmann,et al.  A thermal light source technique for optical coherence tomography , 2000 .

[17]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[18]  M. Akiba,et al.  Full-field optical coherence tomography by two-dimensional heterodyne detection with a pair of CCD cameras. , 2003, Optics letters.

[19]  David Huang,et al.  Handbook of optical coherence tomography. , 2003, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[20]  P Seitz,et al.  Optical coherence topography based on a two-dimensional smart detector array. , 2001, Optics letters.