Construction of flexible enzymatic electrode based on gradient hollow fiber membrane and multi-wall carbon tubes meshes.

In this study, we developed a convenient way to construct a flexible enzymatic electrode with excellent stability and electrochemical performance for implanted glucose monitoring. The electrode was constructed through the co-immobilization of the glucose oxidase micro-particles (GOD MPs) and multi-wall carbon nanotubes (CNT) on the inner surface of a gradient-structured hollow fiber membrane (GHM), where CNT improved the electron transport efficiency and GHM controlled the transfer of substances and interferences. GOD MPs showed higher stability under various operation conditions than the free enzymes due to the MnCO3 template method, which enabled the biosensor to remain relative sensitivity at >86% over 9 days. The GOD MPs biosensor also showed high selectivity, reproducibility, and linear sensing range from 0 mM to 24 mM (R2 = 0.9993) with a current sensitivity of 25 nA/mM. The combination of porous-structured membrane and the flexible CNT meshes ensures the electrical connections and sensing accuracy of the biosensor under the deformation status. In-vivo experiments showed reliable current responses to variations in blood glucose concentrations that were consistent with tail blood test results. This co-immobilization of enzyme micro-particles in the 3D porous structure method developed a bio-composite platform technology towards the applications in flexible sensing and implantable medical devices.

[1]  Adam Heller,et al.  Electrochemical glucose sensors and their applications in diabetes management. , 2008, Chemical reviews.

[2]  Wei Chen,et al.  PVDF-Nafion nanomembranes coated microneedles for in vivo transcutaneous implantable glucose sensing. , 2015, Biosensors & bioelectronics.

[3]  C. Rice-Evans,et al.  Antioxidant activity applying an improved ABTS radical cation decolorization assay. , 1999, Free radical biology & medicine.

[4]  G. S. Wilson,et al.  Covalent enzyme coupling on cellulose acetate membranes for glucose sensor development. , 1988, Analytical chemistry.

[5]  U. Ungerstedt,et al.  Self-Monitoring of Blood Glucose in Type I Diabetic Patients: Comparison With Continuous Microdialysis Measurements of Glucose in Subcutaneous Adipose Tissue During Ordinary Life Conditions , 1997, Diabetes Care.

[6]  Changyou Gao,et al.  Construction of Microreactors for Cascade Reaction and Their Potential Applications as Antibacterial Agents. , 2019, ACS applied materials & interfaces.

[7]  Ye Zhu,et al.  Facile one-step fabrication of glucose oxidase loaded polymeric nanoparticles decorating MWCNTs for constructing glucose biosensing platform: Structure matters. , 2019, Biosensors & bioelectronics.

[8]  Sandro Carrara,et al.  Implantable enzyme amperometric biosensors. , 2012, Biosensors & bioelectronics.

[9]  Yuehe Lin,et al.  Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles , 2004 .

[10]  Viktor Lazorkin,et al.  New Four-Die Forging Devices (FDFD) Design Solutions and Open-Die Forging Technologies , 2018 .

[11]  G G Guilbault,et al.  An enzyme electrode for the amperometric determination of glucose. , 1973, Analytica chimica acta.

[12]  L. Ananthanarayan,et al.  Glucose oxidase--an overview. , 2009, Biotechnology advances.

[13]  Sandeep Kumar Vashist,et al.  Rapid and simple preparation of a reagentless glucose electrochemical biosensor. , 2012, The Analyst.

[14]  S. K. Vashist,et al.  Achievement and assessment of direct electron transfer of glucose oxidase in electrochemical biosensing using carbon nanotubes, graphene, and their nanocomposites , 2017, Microchimica Acta.

[15]  Yang Li,et al.  Top-Down Strategy of Implantable Biosensor Using Adaptable, Porous Hollow Fibrous Membrane. , 2019, ACS sensors.

[16]  D. Gough,et al.  Time‐dependent inactivation of immobilized glucose oxidase and catalase , 1987, Biotechnology and bioengineering.

[17]  S. K. Vashist Non-invasive glucose monitoring technology in diabetes management: a review. , 2012, Analytica chimica acta.

[18]  Mohammad Reza Ganjali,et al.  Recent advances in biosensor technology in assessment of early diabetes biomarkers. , 2018, Biosensors & bioelectronics.

[19]  P. Ajayan Nanotubes from Carbon. , 1999, Chemical reviews.

[20]  S. K. Vashist,et al.  Advances in carbon nanotube based electrochemical sensors for bioanalytical applications. , 2011, Biotechnology advances.

[21]  Sandeep Kumar Vashist,et al.  Continuous Glucose Monitoring Systems: A Review , 2013, Diagnostics.

[22]  Changyou Gao,et al.  Layer-by-layer assembly of microcapsules and their biomedical applications. , 2012, Chemical Society reviews.

[23]  M. Schoenfisch,et al.  In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility. , 2017, Analytical chemistry.

[24]  Tony K. L. Kiang,et al.  Revolutionizing Therapeutic Drug Monitoring with the Use of Interstitial Fluid and Microneedles Technology , 2017, Pharmaceutics.

[25]  Haider Butt,et al.  Hydrogel optical fibers for continuous glucose monitoring. , 2019, Biosensors & bioelectronics.

[26]  A Heller,et al.  Implanted electrochemical glucose sensors for the management of diabetes. , 1999, Annual review of biomedical engineering.

[27]  Sandeep Kumar Vashist,et al.  Technology behind commercial devices for blood glucose monitoring in diabetes management: a review. , 2011, Analytica chimica acta.

[28]  Sandeep Kumar Vashist,et al.  Point-of-care Glucose Detection for Diabetic Monitoring and Management , 2016 .

[29]  Chinnu Sabu,et al.  Advanced biosensors for glucose and insulin. , 2019, Biosensors & bioelectronics.

[30]  Jae Ho Shin,et al.  Biocompatible materials for continuous glucose monitoring devices. , 2013, Chemical reviews.

[31]  S. Sakai,et al.  Immobilization of Pseudomonas cepacia lipase onto electrospun polyacrylonitrile fibers through physical adsorption and application to transesterification in nonaqueous solvent , 2010, Biotechnology Letters.

[32]  G. S. Wilson,et al.  Elimination of the acetaminophen interference in an implantable glucose sensor. , 1994, Analytical chemistry.