콤팩트 형광램프의 전극구조에 대한 고찰

In this paper, we observed an electrode structure that is an important element that decide life of compact fluorescent lamp. We measured winding and application type of electron emission material and electrode damage with SEM(Scanning Electron Microscope). From now on, we need to measure rather several difference aging-time sample than analyze a relation electrode between life.